Your Trusted Source for Industrial Electrical Components

LS-11/P

LS Position switch

Eaton | Safety Position Switches · LS Titan Position Switches | LS-11/P

LS Position switchProduct Type

Additional Technical Details

View Full Specifications
Product Weight0.057 kg
Product Length/Depth33.5 mm
Product Height86 mm
Product Width31 mm

Standards & Approvals

  • DNV
  • IEC/EN 60947-5
  • UL 508
  • CSA
  • CSA-C22.2 No. 14
  • UL

Typical Applications

Machine safety, position detection and interlock monitoring on industrial equipment.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Technical Specifications

General Information
Product NameEaton Moeller® series LS Position switch
Catalog Number266112
Model CodeLS-11/P
EAN4015082661120
Product Length/Depth33.5 mm
Product Height86 mm
Product Width31 mm
Product Weight0.057 kg
CertificationsDNV IEC/EN 60947-5 UL 508 CSA UL Category Control No.: NKCR CSA Class No.: 3211-03 CSA File No.: 012528 UL File No.: E29184 CSA-C22.2 No. 14 UL CE IEC/EN 60947
Catalog NotesThe operating head can be rotated 90° to enable adaptation to the specified approach direction Using the product in areas exposed to ozone and UV radiation or in sub-zero temperatures in unprotected outdoor environments (e.g. altitudes above 1,000 m, unprotected sunlight) may reduce the degree of protection. The customer / user must validate the overall application accordingly. If applicable, the use of the LS-…-CC (Cold Climate) variants should be considered.
Connection typeCage Clamp
Degree of protectionIP66/IP67 NEMA Other
Lifespan8,000,000 mechanical Operations
Operating frequency6000 Operations/h
Overvoltage categoryIII
Pollution degree3
Product categoryRoller plunger
Rated impulse withstand voltage (Uimp)4000 V AC
Repetition accuracy0.15 mm (Contacts/switching capacity)
Suitable forSafety functions
TypeSafety position switch
Environmental Conditions
Mounting positionAs required
Shock resistance25 g, Standard-action contact, Mechanical, Half-sinusoidal shock 20 ms
Ambient operating temperature - max70 °C
Ambient operating temperature - min-25 °C
Climatic proofingDamp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30
Explosion safety category for dustNone
Explosion safety category for gasNone
Standards & Design Verification
10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit ratingIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibilityIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistanceMeets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosuresMeets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiationMeets the product standard's requirements.
10.2.5 LiftingDoes not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated.
10.2.7 InscriptionsMeets the product standard's requirements.
10.3 Degree of protection of assembliesDoes not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distancesMeets the product standard's requirements.
10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.
10.8 Connections for external conductorsIs the panel builder's responsibility.
10.9.2 Power-frequency electric strengthIs the panel builder's responsibility.
10.9.3 Impulse withstand voltageIs the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility.
Equipment heat dissipation, current-dependent Pvid0 W
Heat dissipation capacity Pdiss0 W
Heat dissipation per pole, current-dependent Pvid0.17 W
Rated operational current for specified heat dissipation (In)6 A
Static heat dissipation, non-current-dependent Pvs0 W
Electrical Characteristics
Rated insulation voltage (Ui)400 V
Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V6 A
Rated operational current (Ie) at AC-15, 24 V6 A
Rated operational current (Ie) at AC-15, 380 V, 400 V, 415 V4 A
Rated operational current (Ie) at DC-13, 110 V0.6 A
Rated operational current (Ie) at DC-13, 125 V0.8 A
Rated operational current (Ie) at DC-13, 220 V, 230 V0.3 A
Rated operational current (Ie) at DC-13, 24 V3 A
Short-circuit protection ratingMax. 6 A gG/gL, Fuse, Contacts
Supply frequencyMax. 400 Hz, Contacts
Rated conditional short-circuit current (Iq)1 kA
Features & functions
DesignEN 50047 Form C
Electric connection typeCable entry metrical
Enclosure colorYellow Cover
Enclosure materialInsulated material Plastic
FeaturesPositive opening Forced opening
Switch function typeSlow-action switch
Additional Specifications
Terminal capacity (flexible with ferrule)1 x (0.5 - 1.5) mm²
Terminal capacity (solid)1 x (0.5 - 2.5) mm²
Actuating force at beginning/end of stroke1.0 N/8.0 N
Actuating torque of rotary drives0.2 Nm
Actuator typeRoller cam
Operating speedFor angle of actuation α = 0°/30° Max. 1/1 m/s (with DIN cam, mechanical actuation)
Control circuit reliability1 failure per 5,000,000 switching operations (statistically determined, at 5 V DC/1 mA) 1 failure per 10,000,000 switching operations (Statistically determined, at 24 V DC/5 mA)
Number of contacts (change-over contacts)0
Number of contacts (normally closed contacts)1
Number of contacts (normally open contacts)1

Note: Specifications are taken from the official Eaton LS-11/P product data sheet.

Documents & Downloads

Official technical documentation for the LS-11/P.

Typical Applications

Typical applications of the LS-11/P.

Machine Control
Panel Isolation
Position Sensing
Changeover Switching
Safety Circuits
12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment