LSE-11

Position switch

Eaton | Switches & Cam Switches | 266121

0.2 AAmperage
12 - 30 V DCVoltage
0.019 A (30 V DC)Breaking Capacity
Position switchProduct Type

Additional Technical Details

View Full Specifications
Product Weight0.048 kg
Product Length/Depth33.5 mm
Product Height76.5 mm
Product Width31 mm
Degree Of ProtectionIP66/IP67 NEMA Other

Standards & Approvals

  • Eaton global quality standards

Typical Applications

Machine Control, Panel Isolation, Position Sensing and more.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Technical Specifications

General Information
Product NameEaton Moeller® series LSE Safety position switch
Catalog Number266121
EAN4015082661212
Model CodeLSE-11
Actuator typePlunger
Electric connection typeCable entry metrical
Switch function typeSlow-action switch
Connection typeCage Clamp
Product categoryPosition switch
TypeSafety position switch
Electrical Characteristics
Shock resistance30 g, Basic unit, Mechanical, Half-Sinusoidal shock 20 ms
Temperature resistance100 °C, Contact temperature of roller head
10.11 Short-circuit ratingIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.2.2 Corrosion resistanceMeets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiationMeets the product standard's requirements.
10.9.2 Power-frequency electric strengthIs the panel builder's responsibility.
10.9.3 Impulse withstand voltageIs the panel builder's responsibility.
Equipment heat dissipation, current-dependent Pvid0 W
Heat dissipation capacity Pdiss0 W
Heat dissipation per pole, current-dependent Pvid0.15 W
Rated operational current for specified heat dissipation (In)0.2 A
Static heat dissipation, non-current-dependent Pvs0.4 W
Rated breaking capacity0.019 A (30 V DC)
Rated operational current (Ie) at DC-1, 12 V0.015 A
Rated operational current (Ie) at DC-1, 24 V18 A
Rated operational current (Ie) at DC-13, 24 V0.2 A
Rated operational voltage12 - 30 V DC
Burst impulse2 kV, Supply cable, according to IEC/EN 61000-4-4, Level 3 2 kV, Signal cable, according to IEC/EN 61000-4-4, Level 3
Lifespan3,000,000 electrical Operations 3,000,000 mechanical Operations
Operating frequency3000 Operations/h
Overvoltage categoryIII
Mechanical & Physical
Product Length/Depth33.5 mm
Product Height76.5 mm
Product Width31 mm
Product Weight0.048 kg
Mounting positionAs required
Number of contacts (change-over contacts)0
Number of contacts (normally closed contacts)1
Number of contacts (normally open contacts)1
10.3 Degree of protection of assembliesDoes not apply, since the entire switchgear needs to be evaluated.
10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.
10.8 Connections for external conductorsIs the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility.
Enclosure colorYellow Cover
Enclosure materialPlastic Insulated material
Fitted with:Status indication
Degree of protectionIP66/IP67 NEMA Other
Terminal capacity (flexible with ferrule)1 x (0.5 - 1.5) mm²
Terminal capacity (solid)1 x (0.5 - 2.5) mm²
Environmental & Compliance
CertificationsCE CSA File No.: 012528 CSA-C22.2 No. 14 UL UL Category Control No.: NKCR CSA Class No.: 3211-03 UL 508 CSA IEC/EN 61000-4 UL File No.: E29184 IEC/EN 60947-5 IEC/EN 60947
Ambient operating temperature - max70 °C
Ambient operating temperature - min-25 °C
Climatic proofingDamp heat, cyclic, to IEC 60068-2-30 Damp heat, constant, to IEC 60068-2-78
10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Pollution degree3
Additional Specifications
Catalog NotesUsing the product in areas exposed to ozone and UV radiation or in sub-zero temperatures in unprotected outdoor environments (e.g. altitudes above 1,000 m, unprotected sunlight) may reduce the degree of protection. The customer / user must validate the overall application accordingly. If applicable, the use of the LS-…-CC (Cold Climate) variants should be considered.
Actuating force at beginning/end of stroke3.5 N/8.0 N
Actuating torque of rotary drives0.2 Nm
Operating speedFor angle of actuation α = 0°/30° Max. 1/0.5 m/s (with DIN cam, mechanical actuation)
10.12 Electromagnetic compatibilityIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.3.1 Verification of thermal stability of enclosuresMeets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements.
10.2.5 LiftingDoes not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated.
10.2.7 InscriptionsMeets the product standard's requirements.
10.4 Clearances and creepage distancesMeets the product standard's requirements.
10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.
Air discharge8 kV, according to IEC/EN 61000-4-2, Level 3, ESD
Contact discharge4 kV, according to IEC/EN 61000-4-2, Level 3, ESD
Electromagnetic fields10 V/m (according to IEC EN 61000-4-3)
Immunity to line-conducted interference10 V (according to IEC/EN 61000-4-6)
Surge rating0.5 kV, Power pulses (Surge), according to IEC/EN 61000-4-5, EMC
FeaturesExpandable
FunctionsOutput electronic
IndicationVisual status indication
Rated switching distance (Sn) - max5.5 mm
Rated switching distance (Sn) - min0.5 mm
Repetition accuracy0.02 mm (Contacts/switching capacity)
Suitable forSafety functions
Switching hysteresis of Sn0.4 %

Note: Specifications are taken from the official Eaton LSE-11 datasheet.

Documents & Downloads

Official technical documentation for the LSE-11.

Typical Applications

Typical applications of the LSE-11.

Machine Control
Panel Isolation
Position Sensing
Changeover Switching
Safety Circuits
12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment