Your Trusted Source for Industrial Electrical Components

NZMN1-4-A160

Molded Case Circuit Breakers

Eaton | Molded Case Circuit Breakers

690Voltage
IcnBreaking Capacity

Additional Technical Details

View Full Specifications

Standards & Approvals

  • Eaton global quality standards

Typical Applications

Power Distribution, Motor Protection, Switchgear Assemblies and more.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Technical Specifications

General Information
Delivery program - Installation typeFixed
Electrical Characteristics
Switching capacity - 400/415 V 50 Hz50 kA
Rated current = rated uninterrupted current160 A
Rated current = rated uninterrupted current - Neutral conductor100 %
Short-circuit releases - Non-delayed1280 A fixed
Short-circuit releases - max.1280 A
Circuit-breakers - Rated current = rated uninterrupted current160 A
Circuit-breakers - Rated surge voltage invariabilityUimp
Circuit-breakers - Rated operational voltage690
Circuit-breakers - Overvoltage category/pollution degreeIII/3
Circuit-breakers - Rated insulation voltage690 V
Switching capacity - Rated short-circuit making capacityIcm
Switching capacity - 240 V187 kA
Switching capacity - 400/415 V105 kA
Switching capacity - 440 V 50/60 Hz74 kA
Switching capacity - 525 V 50/60 Hz40 kA
Switching capacity - 690 V 50/60 H17 kA
Switching capacity - Rated short-circuit breaking capacity IcnIcn
Switching capacity - Icu to IEC/EN 60947 test cycle O-t-COkA
Switching capacity - 240 V 50/60 Hz85 kA
Switching capacity - 400/415 V 50/60 Hz50 kA
Switching capacity - 690 V 50/60 Hz10 kA
Switching capacity - Ics to IEC/EN 60947 test cycle O-t-CO-t-COkA
Utilization category to IEC/EN60947-2 A
Max. operating frequency120
Total break time at short-circuit< 10 ms
Mechanical & Physical
Delivery program - Construction sizeNZM1
Delivery program - Number of poles4 pole
Overload trip - Main pole125 - 160 A
General - Protection against direct contactFinger and back of hand proof to VDE 0106 Part 100
Between auxiliary contacts and main contacts500
between the auxiliary contacts300
Degree of protection - DeviceIn the operating controls area: IP20 (basic degree of protection)
Degree of protection - EnclosuresWith insulating surround: IP40 With door coupling rotary handle: IP66
Degree of protection - TerminationsTunnel terminal: IP10 Phase isolator and strip terminal: IP00
Degree of protection - Other technical data (sheet catalogue)Temperature dependency, Derating
Circuit-breakers - Main contacts6000 V
Circuit-breakers - Auxiliary contacts6000 V
Terminal capacity - Standard equipmentBox terminal
Terminal capacity - Optional accessoriesScrew connection Tunnel terminal connection on rear
Box terminal - Solid1 x (10 - 16) 2 x (6 - 16)
Box terminal - Stranded3) 1 x (10 - 70) 2 x (6-25)
Tunnel terminal - Solid1 x 16
Environmental & Compliance
Delivery program - Standard/ApprovalIEC
General - Climatic proofingDamp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature - Operation-25 - +70 °C
Additional Specifications
Delivery program - Product rangeCircuit-breaker
Delivery program - Protective functionSystem and cable protection
Delivery program - Release systemThermomagnetic release
Delivery program - DescriptionSet value in neutral conductor is synchronous with set value Ir of main pole.
Delivery program - Standard equipmentBox terminal
Overload trip - Ir125 - 160 A
General - StandardsIEC/EN 60947
Direction of incoming supplyas required
Circuit-breakers - Use in unearthed supply systems≦ 690 V
AC-1 - 400 V 50/60 Hz7500
415 V 50/60 Hz7500
690 V 50/60 Hz5000

Note: Specifications are taken from the official Eaton NZMN1-4-A160 datasheet.

Documents & Downloads

Official technical documentation for the NZMN1-4-A160.

Typical Applications

Typical applications of the NZMN1-4-A160.

Power Distribution
Motor Protection
Switchgear Assemblies
Industrial Panels
12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment