Your Trusted Source for Industrial Electrical Components

NZMN1-4-A63

NZM molded case circuit breaker thermo-magnetic

Eaton | Digital NZM Moulded Case Circuit Breaker | NZMN1-4-A63

NZM molded case circuit breaker thermo-magneticProduct Type
63 AAmperage Rating

Additional Technical Details

View Full Specifications
Product Weight1.318 kg
Product Length/Depth84.5 mm
Product Height145 mm
Product Width120 mm

Standards & Approvals

  • RoHS conform
  • IEC IEC/EN 60947

Typical Applications

Use in unearthed supply systems at 690 V

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Technical Specifications

General Information
Product NameEaton Moeller series NZM molded case circuit breaker thermo-magnetic
Catalog Number265815
Model CodeNZMN1-4-A63
EAN4015082658151
Product Length/Depth84.5 mm
Product Height145 mm
Product Width120 mm
Product Weight1.318 kg
CompliancesRoHS conform
CertificationsIEC IEC/EN 60947
Amperage Rating63 A
ApplicationUse in unearthed supply systems at 690 V
Circuit breaker frame typeNZM1
FeaturesProtection unit
Number of polesFour-pole
Release systemThermomagnetic release
Special featuresMaximum back-up fuse, if the expected short-circuit currents at the installation location exceed the switching capacity of the circuit breaker (Rated short-circuit breaking capacity Icn) Rated current = rated uninterrupted current: 63 A Set value in neutral conductor is synchronous with set value Ir of main pole. Terminal capacity hint: Up to 95 mm² can be connected depending on the cable manufacturer.
TypeCircuit breaker
Standards & Design Verification
10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit ratingIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibilityIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistanceMeets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosuresMeets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiationMeets the product standard's requirements.
10.2.5 LiftingDoes not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated.
10.2.7 InscriptionsMeets the product standard's requirements.
10.3 Degree of protection of assembliesDoes not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distancesMeets the product standard's requirements.
10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.
10.8 Connections for external conductorsIs the panel builder's responsibility.
10.9.2 Power-frequency electric strengthIs the panel builder's responsibility.
10.9.3 Impulse withstand voltageIs the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility.
Ambient operating temperature - max70 °C
Ambient storage temperature - max70 °C
Ambient operating temperature - min-25 °C
Ambient storage temperature - min40 °C
Equipment heat dissipation, current-dependent14.17 W
Rated operational current for specified heat dissipation (In)63 A
Electrical Characteristics
Amperage Rating63 A
Current rating of neutral conductor200% of phase conductor
Direction of incoming supplyAs required
Electrical connection type of main circuitFrame clamp
Handle typeRocker lever
Instantaneous current setting (Ii) - max10 A
Instantaneous current setting (Ii) - min6 A
Isolation300 V AC (between the auxiliary contacts) 500 V AC (between auxiliary contacts and main contacts)
Lifespan, electrical7500 operations at 690 V AC-1 10000 operations at 400 V AC-1 10000 operations at 415 V AC-1
Number of operations per hour - max120
Overload current setting (Ir)50 A - 63 A
Overload current setting (Ir) - max63 A
Overload current setting (Ir) - min50 A
Overvoltage categoryIII
Pollution degree3
Rated impulse withstand voltage (Uimp) at auxiliary contacts6000 V
Rated impulse withstand voltage (Uimp) at main contacts6000 V
Rated insulation voltage (Ui)690 V AC
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 230 V, 50/60 Hz85 kA
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 400/415 V, 50/60 Hz50 kA
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 440 V, 50/60 Hz35 kA
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 525 V, 50/60 Hz10 kA
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 690 V, 50/60 Hz7.5 kA
Rated short-circuit making capacity Icm at 240 V, 50/60 Hz187 kA
Rated short-circuit making capacity Icm at 400/415 V, 50/60 Hz105 kA
Rated short-circuit making capacity Icm at 440 V, 50/60 Hz74 kA
Rated short-circuit making capacity Icm at 525 V, 50/60 Hz40 kA
Rated short-circuit making capacity Icm at 690 V, 50/60 Hz17 kA
Short-circuit release non-delayed setting - max630 A
Short-circuit release non-delayed setting - min378 A
Short-circuit total breaktime< 10 ms
Utilization categoryA (IEC/EN 60947-2)
Voltage rating690 V - 690 V
Mechanical & Physical
Climatic proofingDamp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30
Degree of protectionIP20 IP20 (basic degree of protection, in the operating controls area)
Degree of protection (IP), front sideIP66 (with door coupling rotary handle) IP40 (with insulating surround)
Degree of protection (terminations)IP10 (tunnel terminal) IP00 (terminations, phase isolator and strip terminal)
Lifespan, mechanical20000 operations
Mounting MethodBuilt-in device fixed built-in technique DIN rail (top hat rail) mounting optional Fixed
Number of auxiliary contacts (change-over contacts)0
Number of auxiliary contacts (normally closed contacts)0
Number of auxiliary contacts (normally open contacts)0
Position of connection for main current circuitFront side
Protection against direct contactFinger and back-of-hand proof to DIN EN 50274/VDE 0106 part 110
Shock resistance20 g (half-sinusoidal shock 20 ms)
Special featuresMaximum back-up fuse, if the expected short-circuit currents at the installation location exceed the switching capacity of the circuit breaker (Rated short-circuit breaking capacity Icn) Rated current = rated uninterrupted current: 63 A Set value in neutral conductor is synchronous with set value Ir of main pole. Terminal capacity hint: Up to 95 mm² can be connected depending on the cable manufacturer.
Terminal Capacities
Optional terminalsConnection on rear. Screw terminal. Tunnel terminal
Standard terminalsBox terminal
Terminal capacity (aluminum solid conductor/cable)16 mm² (1x) at tunnel terminal 10 mm² - 16 mm² (1x) direct at switch rear-side connection 10 mm² - 16 mm² (2x) direct at switch rear-side connection
Terminal capacity (aluminum stranded conductor/cable)25 mm² - 95 mm² (1x) at tunnel terminal 25 mm² - 35 mm² (2x) direct at switch rear-side connection 25 mm² - 35 mm² (1x) direct at switch rear-side connection
Terminal capacity (control cable)0.75 mm² - 2.5 mm² (1x) 0.75 mm² - 1.5 mm² (2x)
Terminal capacity (copper busbar)Min. 12 mm x 5 mm direct at switch rear-side connection M6 at rear-side screw connection Max. 16 mm x 5 mm direct at switch rear-side connection
Terminal capacity (copper solid conductor/cable)10 mm² - 16 mm² (1x) at box terminal 10 mm² - 16 mm² (1x) direct at switch rear-side connection 6 mm² - 16 mm² (2x) at box terminal 6 mm² - 16 mm² (2x) direct at switch rear-side connection 16 mm² (1x) at tunnel terminal
Terminal capacity (copper stranded conductor/cable)10 mm² - 70 mm² (1x) at box terminal 6 mm² - 25 mm² (2x) at box terminal 25 mm² - 95 mm² (1x) at 1-hole tunnel terminal 25 mm² (2x) direct at switch rear-side connection 10 mm² - 70 mm² (1x) direct at switch rear-side connection
Terminal capacity (copper strip)Max. 9 segments of 9 mm x 0.8 mm at box terminal Min. 2 segments of 9 mm x 0.8 mm at box terminal
Additional Specifications
FunctionsSystem and cable protection

Note: Specifications are taken from the official Eaton NZMN1-4-A63 product data sheet.

Documents & Downloads

Official technical documentation for the NZMN1-4-A63.

Typical Applications

Typical applications of the NZMN1-4-A63.

Power Distribution
Motor Protection
Switchgear Assemblies
Industrial Panels
12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment