Your Trusted Source for Industrial Electrical Components

ATO-75-B1I-D10

Current Transducer ATO-75-B1I-D10 I = 75 A

LEM | ATO-Series | IEC 61010-1

500 kHzBandwidth (-1dB)
0.1 % of IPNLinearity Error (Max)
8 mmClearance (dCI)
−30 ... 70 °CAmbient Operating Temperature (TA)
−30 ... 90 °CAmbient Storage Temperature (TA st)

Additional Technical Details

View Full Specifications
Operating Temperature Range−30 ... 70 °C
Isolation Test Voltage4.3 kV
Frequency Bandwidth500 kHz
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud4.3 kV
Impulse Withstand Voltage (1.2/50 µs) UNi7.8 kV
Creepage Distance (dCp)8 mm

Standards & Approvals

  • IEC 61010-1
  • IEC 61010-031 ed1.1
  • IEC 61869-1 ed1.0
  • IEC 61869-2: ed1.0
  • IEC 61869-6: draft
  • UL 508: 2013

Typical Applications

Hybrid inverter (Home Energy Storage), Power metering: current measurement for active power calculation, IBuilding sub-m Ietering: energy efficiency monitoring, Pconsumption anouat lysis and cost allocation anRdL, Power quality monitoring: electrical loads distribution system equipment, Distributed measurement systems, Condition monitoring (e.g. Motor loads such as conveyers, pumps).

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The ATO-75-B1I-D10 is a None current transducer from LEM for the electronic measurement of current: DC, AC, pulsed..., with galvanic isolation.

Typical applications include Hybrid inverter (Home Energy Storage), Power metering: current measurement for active power calculation, IBuilding sub-m Ietering: energy efficiency monitoring, Pconsumption anouat lysis and cost allocation anRdL and Power quality monitoring: electrical loads distribution system equipment.

Key characteristics from the official datasheet: linearity error 0.1 % of IPN; frequency bandwidth 500 kHz; operating temperature −30 ... 70 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesATO
Product ReferenceATO-75-B1I-D10
Measurementcurrent: DC, AC, pulsed...
Mounting—
Application Domain—
Accuracy & Dynamic Performance
Linearity Error (εL)0.1 % of IPN
Frequency Bandwidth500 kHz
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud4.3 kV
Impulse Withstand Voltage (1.2/50 µs) UNi7.8 kV
Creepage Distance (dCp)8 mm
Clearance (dCI)8 mm
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−30 ... 70 °C
Ambient Storage Temperature (TA st)−30 ... 90 °C
Mass (m)80 g
Standards & Certifications
IEC 61010-1Compliance
IEC 61010-031ed1.1:
IEC 61869-1ed1.0:
IEC 61869-2ed1.0:
IEC 61869-6draft
UL 5082013.

Note: Specifications are taken from the official ATO-75-B1I-D10 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the ATO-75-B1I-D10 are shown below.

ATO-75-B1I-D10 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM ATO-75-B1I-D10 datasheet
Outline Dimensions & Mechanical Data
Mass80 g

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the ATO-75-B1I-D10.

Hybrid inverter (Home Energy Storage)
Power metering: current measurement for active power calculation
IBuilding sub-m Ietering: energy efficiency monitoring, Pconsumption anouat lysis and cost allocation anRdL
Power quality monitoring: electrical loads distribution system equipment
Distributed measurement systems
Condition monitoring (e.g. Motor loads such as conveyers, pumps)
IEC 61010-1: 2010

Characteristic Curves

The characteristic curves of the ATO-75-B1I-D10 from the official datasheet are shown below.

ATO-75-B1I-D10 characteristic curves
Characteristic curves — source: LEM ATO-75-B1I-D10 datasheet
Accuracy & Dynamic Characteristics
Linearity Error (εL)0.1 % of IPN
Frequency Bandwidth500 kHz

Note: Refer to the datasheet for the complete set of characteristic curves.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment