Your Trusted Source for Industrial Electrical Components
Home Products LEM Automotive Series CD Series CD 100-S/SP8

CD 100-S/SP8

Closed loop (compensated) current transducer

LEM | CD-Series | Closed loop (compensated) | EN 50155 | Busbar Mount

2 × 100 ANominal Primary Current
±15 VPower Supply
Closed loop (compensated)Technology
±3 %Total Error @ IPN
−40 … +85 °CAmbient Operating Temperature (TA)

Additional Technical Details

View Full Specifications
Supply Voltage±15 V
Operating Temperature Range−40 … +85 °C
Isolation Test Voltage6 kV
Primary Nominal RMS Current (IPN)2 × 100 A
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud6 kV
Creepage Distance (dCp)50 mm

Standards & Approvals

  • EN 50155

Typical Applications

Closed loop (compensated) current transducer, Insulating plastic case recognized according to UL 94-V0. Special features, I = 0 ... ±1 A, T = −40 … +85 °C. Advantages, Excellent accuracy, Very good linearity, Low temperature drift, Optimized delay time, Wide frequency bandwidth, No insertion losses, High immunity to external interference, Current overload capability. Application, Railway security systems. Application Domain, Railway (fixed installations and onboard).

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The CD 100-S/SP8 is a closed loop (compensated) current transducer from LEM.

It offers excellent accuracy, very good linearity, low temperature drift and wide frequency bandwidth. Typical applications include Closed loop (compensated) current transducer, Insulating plastic case recognized according to UL 94-V0. Special features, I = 0 ... ±1 A and T = −40 … +85 °C. Advantages.

Key characteristics from the official datasheet: total error ±3 %; operating temperature −40 … +85 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesCD
Product ReferenceCD 100-S/SP8
Primary Nominal Current2 × 100 A
Supply Voltage±15 V
Measurement—
MountingBusbar Mount
Application DomainRailway (fixed installations and onboard)
Electrical Data — CD 100-S/SP8
Primary Nominal RMS Current (IPN)2 × 100 A
Supply Voltage (UC)±15 V
Accuracy & Dynamic Performance
Total Error (εtot) @ IPN±3 %
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud6 kV
Creepage Distance (dCp)50 mm
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−40 … +85 °C
Ambient Storage Temperature (TA st)−45 … +95 °C
Case MaterialInsulating plastic case recognized according to UL 94-V0.
General Tolerance±0.5 mm
Standards & Certifications
EN 50155Compliance

Note: Specifications are taken from the official CD 100-S/SP8 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the CD 100-S/SP8 are shown below.

CD 100-S/SP8 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM CD 100-S/SP8 datasheet, page 3
Outline Dimensions & Mechanical Data
General Tolerance±0.5 mm
Case MaterialInsulating plastic case recognized according to UL 94-V0.

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the CD 100-S/SP8.

I = 0 ... ±1 A

Characteristic Curves

Characteristic curve diagrams are not included in the CD 100-S/SP8 datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Accuracy & Dynamic Characteristics
Total Error (εtot) @ IPN±3 %

Note: For the full set of performance data, refer to the datasheet.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination