Your Trusted Source for Industrial Electrical Components
Home Products LEM Automotive Series CD Series CD 1000-S/SP6

CD 1000-S/SP6

Closed loop (compensated) current transducer

LEM | CD-Series | Closed loop (compensated) | EN 50155 | Busbar Mount

2 x 1200 ANominal Primary Current
±15 ... 24 VPower Supply
Closed loop (compensated)Technology
DC … 10 kHzBandwidth (-1dB)
±3 %Total Error @ IPN

Additional Technical Details

View Full Specifications
Supply Voltage±15 ... 24 V
Operating Temperature Range−25 … +70 °C
Primary Nominal RMS Current (IPN)2 x 1200 A
Current Consumption (IC)@ U C = ±24 V, @ I P R N = 0 A < 40 mA
Linearity Error (εL)< 1 %
Frequency Bandwidth (BW)DC … 10 kHz

Standards & Approvals

  • EN 50155: 2017
  • EN 50121-3-2

Typical Applications

Closed loop (compensated) current transducer, Insulating plastic case recognized according to UL 94-V0. Special feature, Analog current output. Advantages, Very good linearity, Low temperature drift, Optimized delay time, Wide frequency bandwidth, No insertion losses, Current overload capability. Application, Leakage current detection. Application Domain, Railway (fixed installations and onboard).

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The CD 1000-S/SP6 is a closed loop (compensated) current transducer from LEM.

It offers very good linearity, low temperature drift and wide frequency bandwidth. Typical applications include Closed loop (compensated) current transducer, Insulating plastic case recognized according to UL 94-V0. Special feature, Analog current output. Advantages and Very good linearity.

Key characteristics from the official datasheet: total error ±3 %; linearity error < 1 %; frequency bandwidth DC … 10 kHz; operating temperature −25 … +70 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesCD
Product ReferenceCD 1000-S/SP6
Primary Nominal Current2 x 1200 A
Supply Voltage±15 ... 24 V
Measurement—
MountingBusbar Mount
Application DomainRailway (fixed installations and onboard)
Electrical Data — CD 1000-S/SP6
Primary Nominal RMS Current (IPN)2 x 1200 A
Supply Voltage (UC)±15 ... 24 V
Current Consumption (IC)@ U C = ±24 V, @ I P R N = 0 A < 40 mA
Accuracy & Dynamic Performance
Total Error (εtot) @ IPN±3 %
Linearity Error (εL)< 1 %
Frequency Bandwidth (BW)DC … 10 kHz
Insulation Coordination
Comparative Tracking Index (CTI)225
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−25 … +70 °C
Ambient Storage Temperature (TA st)−40 … +85 °C
Case MaterialInsulating plastic case recognized according to UL 94-V0.
General Tolerance±0.5 mm
Standards & Certifications
EN 501552017
EN 50121-3-2Compliance

Note: Specifications are taken from the official CD 1000-S/SP6 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the CD 1000-S/SP6 are shown below.

CD 1000-S/SP6 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM CD 1000-S/SP6 datasheet, page 3
Outline Dimensions & Mechanical Data
General Tolerance±0.5 mm
Case MaterialInsulating plastic case recognized according to UL 94-V0.

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the CD 1000-S/SP6.

Optimized delay time
Wide frequency bandwidth

Characteristic Curves

Characteristic curve diagrams are not included in the CD 1000-S/SP6 datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Accuracy & Dynamic Characteristics
Total Error (εtot) @ IPN±3 %
Linearity Error (εL)< 1 %
Frequency Bandwidth (BW)DC … 10 kHz

Note: For the full set of performance data, refer to the datasheet.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment