Your Trusted Source for Industrial Electrical Components

DHR 400 C420

True RMS current transducer with 4-20 mA output

LEM | DHR-Series | for Safety | Panel Mount

2) +20 ... 50 V DCPower Supply
currents: DC, AC, pulsed...Measurement
7.2 mmCreepage Distance (dCp)
600Comparative Tracking Index (CTI)
Over voltage category CAT · Pollution degree PD2Overvoltage Category / Pollution Degree

Additional Technical Details

View Full Specifications
Supply Voltage2) +20 ... 50 V DC
Operating Temperature Range−40 ... +70 °C
Isolation Test Voltage4.0 kV
Current Consumption (IC)30 mA + I Advantages
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud4.0 kV
Impulse Withstand Voltage (1.2/50 µs) UNi7.3 kV

Standards & Approvals

  • for Safety

Typical Applications

VFD Controlled Loads VFD output indicates how the motor and attached load are operating, SCR Controlled Loads Acurate measurement of phase angle fired or burst fired (time proportioned) SCRs. Current measurement gives faster response than temperature measurement, Switching Power Supplies and Electronic Ballasts True RMS sensing is the most accurate way to measure power supply or ballast input power. Application Domain, Energy and Automation.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The DHR 400 C420 is a None current transducer from LEM for the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation.

Typical applications include VFD Controlled Loads VFD output indicates how the motor and attached load are operating, SCR Controlled Loads Acurate measurement of phase angle fired or burst fired (time proportioned) SCRs. Current measurement gives faster response than temperature measurement, Switching Power Supplies and Electronic Ballasts True RMS sensing is the most accurate way to measure power supply or ballast input power. Application Domain and Energy and Automation. Page 1/4 LEM International SA Chemin des Aulx 8 www.lem.com.

Key characteristics from the official datasheet: operating temperature −40 ... +70 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesDHR
Product ReferenceDHR 400 C420
Supply Voltage2) +20 ... 50 V DC
Measurementcurrents: DC, AC, pulsed...
MountingPanel Mount
Application DomainEnergy and Automation
Electrical Data — DHR 400 C420
Supply Voltage (UC)2) +20 ... 50 V DC
Current Consumption (IC)30 mA + I Advantages
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud4.0 kV
Impulse Withstand Voltage (1.2/50 µs) UNi7.3 kV
Creepage Distance (dCp)7.2 mm
Clearance (dCI)7.2 mm
Comparative Tracking Index (CTI)600
Overvoltage Category / Pollution DegreeOver voltage category CAT · Pollution degree PD2
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−40 ... +70 °C
Ambient Storage Temperature (TA st)−40 ... +85 °C
Mass (m)260 g
Case MaterialInsulating plastic case recognized according to UL 94-V0.
Standards & Certifications
for Safety

Note: Specifications are taken from the official DHR 400 C420 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the DHR 400 C420 are shown below.

DHR 400 C420 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM DHR 400 C420 datasheet, page 4
Outline Dimensions & Mechanical Data
Mass260 g
Case MaterialInsulating plastic case recognized according to UL 94-V0.

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the DHR 400 C420.

VFD Controlled Loads VFD output indicates how the motor and attached load are operating
SCR Controlled Loads Acurate measurement of phase angle fired or burst fired (time proportioned) SCRs. Current measurement gives faster response than temperature measurement
Switching Power Supplies and Electronic Ballasts True RMS sensing is the most accurate way to measure power supply or ballast input power. Application Domain
Energy and Automation. Page 1/4 LEM International SA Chemin des Aulx 8 www.lem.com

Characteristic Curves

Characteristic curve diagrams are not included in the DHR 400 C420 datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Note: For the full set of performance data, refer to the datasheet.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment