Authorized Distributor
?
Voltage transducer
| Primary Nominal RMS Voltage | 2000 V |
| Primary Voltage Measuring Range | ± 3000 V |
| Secondary Nominal RMS Current | 50 mA |
| Operating Temperature Range | −40 … 85 °C |
| RMS Voltage for AC Insulation Test | 18.5 kV |
| Measuring Resistance (RM) | 0 .. 133.3 Ohm |
Single or three phase inverters, Propulsion and braking choppers, Propulsion converters, Auxiliary converters, High power drives, Substations, On-board energy meters
The DV 2000/SP2 is a None current transducer from LEM for the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation, delivering a output rms current noise (ino) of Typ 10 μA.
It offers excellent accuracy and low temperature drift. Typical applications include Single or three phase inverters, Propulsion and braking choppers, Propulsion converters and Auxiliary converters.
Key characteristics from the official datasheet: linearity error ± 0.1 %; frequency bandwidth 12 kHz (−3 dB); operating temperature −40 … 85 °C; nominal secondary output 50 mA.
| General Information | |
|---|---|
| Manufacturer | LEM |
| Product Series | DV |
| Product Reference | DV 2000/SP2 |
| Nominal Primary Voltage | 2000 V |
| Supply Voltage | ±13.5 .. ±26.4 V |
| Measurement | voltage: DC, AC, pulsed... |
| Mounting | — |
| Application Domain | Railway (fixed installations and onboard) |
| Electrical Data — DV 2000/SP2 | |
|---|---|
| Primary Nominal RMS Voltage (UPN) | 2000 V |
| Primary Voltage, Measuring Range (UPM) | ± 3000 V |
| Measuring Resistance (RM) | 0 .. 133.3 Ohm |
| Secondary Nominal RMS Current (ISN) | 50 mA |
| Secondary Current (IS) | ± 75 mA |
| Supply Voltage (UC) | ±13.5 .. ±26.4 V |
| Current Consumption (IC) | 24 mA @ ±UC = ±0 V |
| Resistance of Primary (RP) | 23 MOhm |
| Total Primary Power Loss | 0.17 W |
| Insulation Resistance (RINS) | 200 MOhm |
| Supply voltage (±UC) | Min ±13.5 / Typ ±24 / Max ±26.4 V |
| Offset current (IO) | Min −50 / Typ 0 / Max 50 μA |
| Sensitivity (G) | Typ 25 µA/V |
| Sensitivity error (εG) | Min −0.2 / Typ 0 / Max 0.2 % |
| Thermal drift of sensitivity (εGT) | Min −0.5 −0.8 −0.8 / Max 0.5 0.8 0.8 % |
| Output RMS current noise (Ino) | Typ 10 μA |
| Start-up time (tstart) | Typ 190 / Max 250 ms |
| Resistance of primary (winding) (RP) | Typ 23 MΩ |
| Absolute Maximum Ratings | |
|---|---|
| (U Maximum supply voltage = 0 V, 0.1 s) P (±ÛCmax) | ±34 V |
| Absolute Maximum Ratings | |
|---|---|
| Maximum supply voltage (working) (−40 … 85 °C) (±UCmax) | ±26.4 V |
| Absolute Maximum Ratings | |
|---|---|
| Maximum primary voltage (−40 … 85 °C) (UPmax) | 3 kV |
| Absolute Maximum Ratings | |
|---|---|
| Maximum steady state primary voltage (−40 … 85 °C) (UPNmax) | 2000 V see derating on figure 2 |
| Accuracy & Dynamic Performance | |
|---|---|
| Sensitivity Error | ± 0.2 % |
| Linearity Error (εL) | ± 0.1 % |
| Frequency Bandwidth (BW) | 12 kHz (−3 dB) |
| Start-up Time | 190 .. 250 ms |
| Insulation Coordination | |
|---|---|
| RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud | 18.5 kV |
| Impulse Withstand Voltage (1.2/50 µs) UNi | 30 kV |
| Comparative Tracking Index (CTI) | 600 |
| Partial Discharge Test Voltage (Ut) | 5000 V |
| Pollution Degree | 4 |
| Rated Altitude | 2000 m |
| Mean failure rate (λ) | Typ 1/1883371 h-1 |
| RMS voltage for AC insulation test, 50 Hz, 1 min (Ud) | 18.5 kV |
| Impulse withstand voltage 1.2/50 µs (ÛW) | 30 kV |
| Partial discharge extinction RMS voltage @ 10 pC (Ue) | 5000 V |
| Clearance (pri. - sec.) (dCI) | see dimensions mm |
| Creepage distance (pri. - sec.) (dCp) | drawing on page 10 mm |
| Environmental & Mechanical Characteristics | |
|---|---|
| Ambient Operating Temperature (TA) | −40 … 85 °C |
| Ambient Storage Temperature (TA st) | −50 … 90 °C |
| Mass (m) | 640 g |
| Case Material | V0 according to UL 94 |
| Ingress Protection Rating | IP40 |
| Relative humidity (RH) | Max 95 % |
| Standards & Certifications | |
|---|---|
| EN 50155 | 2017 |
| EN 50124-1 | 2017 |
| EN 50121-3-2 | 2016 |
Note: Specifications are taken from the official DV 2000/SP2 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.
Official technical documentation for the DV 2000/SP2.
Outline dimensions, pin layout and connection diagrams of the DV 2000/SP2 are shown below.
| Outline Dimensions & Mechanical Data | |
|---|---|
| Mass | 640 g |
| Resistance of primary (winding) (RP) | Typ 23 MΩ |
| Case Material | V0 according to UL 94 |
| Ingress Protection Rating | IP40 |
Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.
Typical applications of the DV 2000/SP2.
The characteristic curves of the DV 2000/SP2 from the official datasheet are shown below.
| Accuracy & Dynamic Characteristics | |
|---|---|
| Sensitivity (G) | Typ 25 µA/V |
| Sensitivity error (εG) | Min −0.2 / Typ 0 / Max 0.2 % |
| Thermal drift of sensitivity (εGT) | Min −0.5 −0.8 −0.8 / Max 0.5 0.8 0.8 % |
| Sensitivity Error | ± 0.2 % |
| Linearity Error (εL) | ± 0.1 % |
| Frequency Bandwidth (BW) | 12 kHz (−3 dB) |
Note: Refer to the datasheet for the complete set of characteristic curves.