Your Trusted Source for Industrial Electrical Components
Home Products LEM Voltage Sensors DV Series DV 4000/SP2

DV 4000/SP2

Voltage Transducer

LEM | DV-Series | EN 50155

4000 VNominal Primary Voltage
± 0.5 % (−25 … 70 °C) / ± 0.8 % (−25 … 85 °C) / ± 0.8 % (−40 … 85 °C) / ± 0.3 % (25 °C) / ± 0.7 % (−25 … 70 °C) / ± 1 % (−25 … 85 °C) / ± 1 % (−40 … 85 °C)Total Error @ IPN
± 0.1 %Linearity Error (Max)
± 0.5 % (−25 … 70 °C) / ± 0.8 % (−25 … 85 °C) / ± 0.8 % (−40 … 85 °C) / ± 0.3 % (25 °C) / ± 0.7 % (−25 … 70 °C) / ± 1 % (−25 … 85 °C) / ± 1 % (−40 … 85 °C)Total Error (εtot) @ IPN
± 0.1 %Linearity Error (εL)

Additional Technical Details

View Full Specifications
Secondary Nominal Current50 A
Operating Temperature Range−40 … 85 °C
Secondary Nominal RMS Current (ISN)50 A
⎓ Maximum supply voltage (working) (−40 … 85 °C) (±UCmax)±26.4 V
Maximum primary voltage (−40 … 85 °C) (UPmax)6 kV
Maximum steady state primary voltage (−40 … 85 °C) (UPNmax)4000 V see derating on figure 2

Standards & Approvals

  • EN 50155:

Typical Applications

UNVERIFIED

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The DV 4000/SP2 is a None current transducer from LEM for the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation.

It offers excellent accuracy and low temperature drift. Typical applications include UNVERIFIED.

Key characteristics from the official datasheet: total error ± 0.5 % (−25 … 70 °C) / ± 0.8 % (−25 … 85 °C) / ± 0.8 % (−40 … 85 °C) / ± 0.3 % (25 °C) / ± 0.7 % (−25 … 70 °C) / ± 1 % (−25 … 85 °C) / ± 1 % (−40 … 85 °C); linearity error ± 0.1 %; operating temperature −40 … 85 °C; nominal secondary output 50 A.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesDV
Product ReferenceDV 4000/SP2
Nominal Primary Voltage4000 V
Measurementvoltage: DC, AC, pulsed...
Mounting—
Application DomainRailway (fixed installations and onboard)
Electrical Data — DV 4000/SP2
Secondary Nominal RMS Current (ISN)50 A
Absolute Maximum Ratings
⎓ Maximum supply voltage (working) (−40 … 85 °C) (±UCmax)±26.4 V
Absolute Maximum Ratings
Maximum primary voltage (−40 … 85 °C) (UPmax)6 kV
Absolute Maximum Ratings
Maximum steady state primary voltage (−40 … 85 °C) (UPNmax)4000 V see derating on figure 2
Accuracy & Dynamic Performance
Total Error (εtot) @ IPN± 0.5 % (−25 … 70 °C) / ± 0.8 % (−25 … 85 °C) / ± 0.8 % (−40 … 85 °C) / ± 0.3 % (25 °C) / ± 0.7 % (−25 … 70 °C) / ± 1 % (−25 … 85 °C) / ± 1 % (−40 … 85 °C)
Linearity Error (εL)± 0.1 %
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−40 … 85 °C
Ambient Storage Temperature (TA st)−50 … 90 °C
Mass (m)610 g
Relative humidity (RH)Max 95 %
Ingress protection ratingTyp IP40
Pollution degreeMax PD4
AltitudeMax 1) 2000 m
Standards & Certifications
EN 50155Compliance
Insulation Coordination
Mean failure rate (λ)Typ 1/1883371 h-1
RMS voltage for AC insulation test, 50 Hz, 1 min (Ud)18.5 kV
Impulse withstand voltage 1.2/50 µs (UNi)30 kV
(q < 10 pC) Partial discharge RMS voltage m (Ut)5000 V
Insulation resistance (RINS)200 MΩ
Clearance (pri. - sec.) (dCI)see dimensions mm
Creepage distance (pri. - sec.) (dCp)drawing on page 10 mm
Case materialV0
Primary nominal RMS voltage (UPN)Typ 4000 V
Primary voltage, measuring range (UPM)Min −6000 / Max 6000 V
Measuring resistance (RM)Min 0 / Max 133.3 Ω
Secondary current (IS)Min −75 / Max 75 mA
⎓ Supply voltage (±UC)Min ±13.5 / Typ ±24 / Max ±26.4 V
U Rise time of (10-90 %) C (trise)Max 100 ms
⎓ Current consumption (IC)Typ I 20 + S / Max I 25 + S mA
Electrical Offset current (IOE)Min −50 / Typ 0 / Max 50 μA
Sensitivity (S)Typ 12.5 µA/V
Sensitivity error (εS)Min −0.2 / Typ 0 / Max 0.2 %
Temperature variation of sensitivity error (εST)Min −0.5 −0.8 −0.8 / Max 0.5 0.8 0.8 %
Linearity error (εL)Min −0.1 / Max 0.1 U % of P M
RMS noise current (Ino)Typ 10 μA
Start-up time (tstart)Typ 190 / Max 250 ms
Resistance of primary (winding) (RP)Typ 23 MΩ

Note: Specifications are taken from the official DV 4000/SP2 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the DV 4000/SP2 are shown below.

DV 4000/SP2 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM DV 4000/SP2 datasheet
Outline Dimensions & Mechanical Data
Mass610 g
Ingress protection ratingTyp IP40
Case materialV0
Resistance of primary (winding) (RP)Typ 23 MΩ

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the DV 4000/SP2.

UNVERIFIED

Characteristic Curves

The characteristic curves of the DV 4000/SP2 from the official datasheet are shown below.

DV 4000/SP2 characteristic curves
Characteristic curves — source: LEM DV 4000/SP2 datasheet
Accuracy & Dynamic Characteristics
Total Error (εtot) @ IPN± 0.5 % (−25 … 70 °C) / ± 0.8 % (−25 … 85 °C) / ± 0.8 % (−40 … 85 °C) / ± 0.3 % (25 °C) / ± 0.7 % (−25 … 70 °C) / ± 1 % (−25 … 85 °C) / ± 1 % (−40 … 85 °C)
Linearity Error (εL)± 0.1 %
U Rise time of (10-90 %) C (trise)Max 100 ms
Sensitivity (S)Typ 12.5 µA/V
Sensitivity error (εS)Min −0.2 / Typ 0 / Max 0.2 %
Temperature variation of sensitivity error (εST)Min −0.5 −0.8 −0.8 / Max 0.5 0.8 0.8 %

Note: Refer to the datasheet for the complete set of characteristic curves.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment