Authorized Distributor
?
Ratiometric transducer
| Primary Current, Measuring Range | ± 1400 A |
| Supply Voltage | 4.85 .. 5.15 V |
| Sensitivity | 1.43 mV/A |
| Operating Temperature Range | −40 .. 125 °C |
| Isolation Test Voltage | 3.6 kV |
| Primary Nominal Current (IPN) | ± 1400 A |
Compact design for PCB mounting. Therefore: Hall.
The HC16F 1400-S00 is an open loop current transducer from LEM for the electronic measurement of DC, AC or pulsed currents, with galvanic isolation, delivering an instantaneous output voltage of 2.5 V.
It offers excellent accuracy and very good linearity. Typical applications include Compact design for PCB mounting. Therefore: Hall.
Key characteristics from the official datasheet: linearity error ± 0.5 %; frequency bandwidth 40 kHz; operating temperature −40 .. 125 °C.
| General Information | |
|---|---|
| Manufacturer | LEM |
| Product Series | HC |
| Product Reference | HC16F 1400-S00 |
| Primary Nominal Current | ± 1400 A |
| Supply Voltage | 4.85 .. 5.15 V |
| Measurement | DC, AC or pulsed currents |
| Mounting | PCB Mount |
| Application Domain | Compact design for PCB mounting. Therefore: Hall |
| Electrical Data — HC16F 1400-S00 | |
|---|---|
| Primary Nominal Current (IPN) | ± 1400 A |
| Primary Current, Measuring Range (IPM) | ± 1400 A |
| Supply Voltage (UC) | 4.85 .. 5.15 V |
| Current Consumption (IC) | 28 .. 35 mA |
| Sensitivity | 1.43 mV/A |
| Output Offset Voltage (VO E) | 2.5 V |
| Accuracy & Dynamic Performance | |
|---|---|
| Ratiometricity Error | ± 0.3 % |
| Sensitivity Error | ± 0.5 % |
| Linearity Error | ± 0.5 % |
| Delay Time (tD) | 2 .. 4 µs |
| Frequency Bandwidth | 40 kHz |
| Output Noise | 15 mV |
| Insulation Coordination | |
|---|---|
| RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud | 3.6 kV |
| Creepage Distance (dCp) | 11 mm |
| Clearance (dCI) | 5 mm |
| Comparative Tracking Index (CTI) | PLC3 |
| Environmental & Mechanical Characteristics | |
|---|---|
| Ambient Operating Temperature (TA) | −40 .. 125 °C |
| Ambient Storage Temperature (TA st) | −40 .. 125 °C |
| Mass (m) | 29 g |
Note: Specifications are taken from the official HC16F 1400-S00 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.
Official technical documentation for the HC16F 1400-S00.
Outline dimensions, pin layout and connection diagrams of the HC16F 1400-S00 are shown below.
| Outline Dimensions & Mechanical Data | |
|---|---|
| Mass | 29 g |
Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.
Typical applications of the HC16F 1400-S00.
The characteristic curves of the HC16F 1400-S00 from the official datasheet are shown below.
| Accuracy & Dynamic Characteristics | |
|---|---|
| Sensitivity | 1.43 mV/A |
| Sensitivity Error | ± 0.5 % |
| Linearity Error | ± 0.5 % |
| Frequency Bandwidth | 40 kHz |
Note: Refer to the datasheet for the complete set of characteristic curves.