Authorized Distributor
?
Open Loop transducer using the Hall effect
| Supply Voltage | 4.75 .. 5.25 V |
| Sensitivity | 10 mV/A |
| Isolation Test Voltage | 2.5 kV |
| Current Consumption (IC) | 19 .. 25 mA |
| Output Offset Voltage (VO E) | 2.5 V |
| Load Resistance (RL) | 10 kOhm |
Cover without sleeve (reduced insulation).
The HC5FW 200-S/SP1 is an open loop current transducer from LEM delivering an instantaneous output voltage of 2.5 V.
Typical applications include Cover without sleeve (reduced insulation).
Key characteristics from the official datasheet: frequency bandwidth 40 kHz.
| General Information | |
|---|---|
| Manufacturer | LEM |
| Product Series | HC |
| Product Reference | HC5FW 200-S/SP1 |
| Supply Voltage | 4.75 .. 5.25 V |
| Measurement | — |
| Mounting | Busbar Mount |
| Application Domain | Cover without sleeve (reduced insulation) |
| Electrical Data — HC5FW 200-S/SP1 | |
|---|---|
| Supply Voltage (UC) | 4.75 .. 5.25 V |
| Current Consumption (IC) | 19 .. 25 mA |
| Sensitivity | 10 mV/A |
| Output Offset Voltage (VO E) | 2.5 V |
| Load Resistance (RL) | 10 kOhm |
| Accuracy & Dynamic Performance | |
|---|---|
| Ratiometricity Error | 0.5 % |
| Sensitivity Error | ± 0.6 % |
| Delay Time (tD) | 2 .. 6 µs |
| Frequency Bandwidth | 40 kHz |
| Output Noise | 13 mV |
| Insulation Coordination | |
|---|---|
| RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud | 2.5 kV |
| Creepage Distance (dCp) | 3.6 mm |
| Clearance (dCI) | 2.7 mm |
| Environmental & Mechanical Characteristics | |
|---|---|
| Mass (m) | 27.5 g |
Note: Specifications are taken from the official HC5FW 200-S/SP1 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.
Official technical documentation for the HC5FW 200-S/SP1.
Outline dimensions, pin layout and connection diagrams of the HC5FW 200-S/SP1 are shown below.
| Outline Dimensions & Mechanical Data | |
|---|---|
| Mass | 27.5 g |
Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.
Typical applications of the HC5FW 200-S/SP1.
The characteristic curves of the HC5FW 200-S/SP1 from the official datasheet are shown below.
| Accuracy & Dynamic Characteristics | |
|---|---|
| Sensitivity | 10 mV/A |
| Sensitivity Error | ± 0.6 % |
| Frequency Bandwidth | 40 kHz |
| Reference Conditions | |
|---|---|
| Ambient Temperature (TA) | 25 °C, unless otherwise noted |
| Output Load Resistance (RL) | 10 kOhm |
Note: Refer to the datasheet for the complete set of characteristic curves.