Your Trusted Source for Industrial Electrical Components
Home Products LEM Automotive Series HC Series HC5FW 200-S/SP1

HC5FW 200-S/SP1

Open Loop transducer using the Hall effect

LEM | HC-Series | Open Loop Transducer | Busbar Mount

4.75 .. 5.25 VPower Supply
Open Loop TransducerTechnology
40 kHzBandwidth (-1dB)
0.5 %Ratiometricity Error
± 0.6 %Sensitivity Error

Additional Technical Details

View Full Specifications
Supply Voltage4.75 .. 5.25 V
Sensitivity10 mV/A
Isolation Test Voltage2.5 kV
Current Consumption (IC)19 .. 25 mA
Output Offset Voltage (VO E)2.5 V
Load Resistance (RL)10 kOhm

Standards & Approvals

Typical Applications

Cover without sleeve (reduced insulation).

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Technical Specifications

General Information
ManufacturerLEM
Product SeriesHC
Product ReferenceHC5FW 200-S/SP1
Supply Voltage4.75 .. 5.25 V
Measurement—
MountingBusbar Mount
Application DomainCover without sleeve (reduced insulation)
Electrical Data — HC5FW 200-S/SP1
Supply Voltage (UC)4.75 .. 5.25 V
Current Consumption (IC)19 .. 25 mA
Sensitivity10 mV/A
Output Offset Voltage (VO E)2.5 V
Load Resistance (RL)10 kOhm
Accuracy & Dynamic Performance
Ratiometricity Error0.5 %
Sensitivity Error± 0.6 %
Delay Time (tD)2 .. 6 µs
Frequency Bandwidth40 kHz
Output Noise13 mV
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud2.5 kV
Creepage Distance (dCp)3.6 mm
Clearance (dCI)2.7 mm
Environmental & Mechanical Characteristics
Mass (m)27.5 g

Note: Specifications are taken from the official HC5FW 200-S/SP1 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the HC5FW 200-S/SP1 are shown below.

HC5FW 200-S/SP1 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM HC5FW 200-S/SP1 datasheet, page 2
Outline Dimensions & Mechanical Data
Mass27.5 g

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the HC5FW 200-S/SP1.

Cover without sleeve (reduced insulation)

Characteristic Curves

The characteristic curves of the HC5FW 200-S/SP1 from the official datasheet are shown below.

HC5FW 200-S/SP1 characteristic curves
Characteristic curves — source: LEM HC5FW 200-S/SP1 datasheet
Accuracy & Dynamic Characteristics
Sensitivity10 mV/A
Sensitivity Error± 0.6 %
Frequency Bandwidth40 kHz
Reference Conditions
Ambient Temperature (TA)25 °C, unless otherwise noted
Output Load Resistance (RL)10 kOhm

Note: Refer to the datasheet for the complete set of characteristic curves.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment