Your Trusted Source for Industrial Electrical Components
Home Products LEM Automotive Series HC Series HC5FW 500-S/SP1

HC5FW 500-S/SP1

Open Loop transducer using the Hall effect

LEM | HC-Series | Open Loop Transducer | Busbar Mount

± 500 ANominal Primary Current
4.75 .. 5.25 VPower Supply
Open Loop TransducerTechnology
40 kHzBandwidth (-1dB)
± 1 %Linearity Error (Max)

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range± 500 A
Supply Voltage4.75 .. 5.25 V
Sensitivity4 mV/A
Operating Temperature Range−40 .. 125 °C
Isolation Test Voltage2.5 kV
Primary Nominal Current (IPN)± 500 A

Standards & Approvals

Typical Applications

Cover without sleeve (reduced insulation).

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The HC5FW 500-S/SP1 is an open loop current transducer from LEM delivering an instantaneous output voltage of 2.5 V.

It offers excellent accuracy and very good linearity. Typical applications include Cover without sleeve (reduced insulation).

Key characteristics from the official datasheet: linearity error ± 1 %; frequency bandwidth 40 kHz; operating temperature −40 .. 125 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesHC
Product ReferenceHC5FW 500-S/SP1
Primary Nominal Current± 500 A
Supply Voltage4.75 .. 5.25 V
Measurement—
MountingBusbar Mount
Application DomainCover without sleeve (reduced insulation)
Electrical Data — HC5FW 500-S/SP1
Primary Nominal Current (IPN)± 500 A
Primary Current, Measuring Range (IPM)± 500 A
Supply Voltage (UC)4.75 .. 5.25 V
Current Consumption (IC)19 .. 25 mA
Sensitivity4 mV/A
Output Offset Voltage (VO E)2.5 V
Load Resistance (RL)10 kOhm
Insulation Resistance (RINS)500 MOhm
Accuracy & Dynamic Performance
Ratiometricity Error0.5 %
Sensitivity Error± 0.6 %
Linearity Error± 1 %
Delay Time (tD)2 .. 6 µs
Frequency Bandwidth40 kHz
Output Noise12 mV
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud2.5 kV
Creepage Distance (dCp)3.6 mm
Clearance (dCI)2.7 mm
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−40 .. 125 °C
Ambient Storage Temperature (TA st)−40 .. 125 °C
Mass (m)27.5 g

Note: Specifications are taken from the official HC5FW 500-S/SP1 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the HC5FW 500-S/SP1 are shown below.

HC5FW 500-S/SP1 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM HC5FW 500-S/SP1 datasheet
Outline Dimensions & Mechanical Data
Mass27.5 g

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the HC5FW 500-S/SP1.

Cover without sleeve (reduced insulation)

Characteristic Curves

The characteristic curves of the HC5FW 500-S/SP1 from the official datasheet are shown below.

HC5FW 500-S/SP1 characteristic curves
Characteristic curves — source: LEM HC5FW 500-S/SP1 datasheet
Accuracy & Dynamic Characteristics
Sensitivity4 mV/A
Sensitivity Error± 0.6 %
Linearity Error± 1 %
Frequency Bandwidth40 kHz
Reference Conditions
Ambient Temperature (TA)25 °C, unless otherwise noted
Output Load Resistance (RL)10 kOhm

Note: Refer to the datasheet for the complete set of characteristic curves.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment