Your Trusted Source for Industrial Electrical Components

HO 25-NPPR

Hall effect measuring principle

LEM | HO-Series | IEC 61010-1 | PCB Mount

25 ANominal Primary Current
4.5 ... 5.5 VPower Supply
250 kHzBandwidth (-3dB)
±1.0 % of IPNOverall Accuracy @ IPN
±3.4 % of IPNAccuracy @ IPN @ TA = +85 °C

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range−62.5 ... 62.5 At
Internal Reference Voltage0.48 ... 0.52, 1.48 ... 1.52, 1.63 ... 1.67, 2.48 ... 2.52 V (2.5 V default)
Electrical Offset Voltage−6 ... 6 mV
Step Response Time to 90 % of IPN3.5 µs (250 kHz filter)
Isolation Test Voltage4.3 kV
Operating Temperature Range−40 ... 105 °C

Standards & Approvals

  • IEC 61010-1
  • IEC 61326-1
  • UL 508: 2010

Typical Applications

Extremely low profile 12 mm, AC variable speed and servo motor drives, Single power supply +5 V, Static converters for DC motor drives, Adjustable offset & sensitivity, Battery supplied applications, Adjustable over current detect (default: 2.9 × I peak value), PN, Uninterruptible Power Supplies (UPS), Adjustable response time and noise level, Switched Mode Power Supplies (SMPS), V pin with adjustable REF OUT & REF IN modes, ref, Power supplies for welding applications, Memory check, Renewable Energy (Solar and Wind), Standby mode with reduced consumption, Current range programming.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Technical Specifications

General Information
ManufacturerLEM
Product SeriesHO
Product ReferenceHO 25-NPPR
Primary Nominal Current25 A
Supply Voltage4.5 ... 5.5 V
Measurementcurrent: DC, AC, pulsed...
MountingPCB Mount
Application DomainIndustrial
Accuracy & Dynamic Performance
Accuracy @ IPN±1.0 % of IPN
Accuracy @ IPN @ TA = +85 °C±3.4 % of IPN
Accuracy @ IPN @ TA = +105 °C±4.2 % of IPN
Sensitivity Error (εG)±0.5 %
Temperature Coefficient of G (TCG)±250 ppm/K
Linearity Error 0 .. IPN (εL)±0.5 % of IPN
Linearity Error 0 .. IPM (εL)±0.8 % of IPM
Temperature Coefficient of Vref (TCVref)±190 ppm/K
Temperature Coefficient of VO E (TCVOE)±0.12 mV/K
Magnetic Offset Voltage after 2.5 × IPN (VOM)±6 mV
Reaction Time @ 10 % of IPN (tra)2.0 µs (250 kHz filter)
Step Response Time to 90 % of IPN (tr)3.5 µs (250 kHz filter)
Frequency Bandwidth (-3 dB) (BW)250 kHz
Over-Current Detect (peak)2.6 ... 3.2 × IPN (peak)
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud4.3 kV
Impulse Withstand Voltage (1.2/50 µs) UNi8 kV
Partial Discharge Test Voltage (q < 10 pC) Um t1650 V
Creepage Distance (dCp)8 mm
Clearance (dCI)8 mm
Case MaterialV0 according to UL 94
Comparative Tracking Index (CTI)600
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−40 ... 105 °C
Ambient Storage Temperature (TA st)−40 ... 105 °C
Surrounding Temperature according to UL 508105 °C
Mass (m)5 g
Standards & Certifications
IEC 61010-1Compliance
IEC 61326-1Compliance
UL 5082010.
EN 501781997
Electrical Data — HO 25-NPPR
Primary Nominal RMS Current (IPN)25 At
Primary Current, Measuring Range (IPM)−62.5 ... 62.5 At
Number of Primary Turns (NP)1, 2, 3
Supply Voltage (UC)4.5 ... 5.5 V
Current Consumption (IC)25 mA
Internal Reference Voltage (Vref)0.48 ... 0.52, 1.48 ... 1.52, 1.63 ... 1.67, 2.48 ... 2.52 V (2.5 V default)
External Reference Voltage (Vref)0.5 ... 2.65 V
Electrical Offset Voltage referred to primary (VO E)−6 ... 6 mV
Theoretical Sensitivity (Gth)32 mV/A

Note: Specifications are taken from the official HO 25-NPPR datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the HO 25-NPPR are shown below.

HO 25-NPPR outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM HO 25-NPPR datasheet
Outline Dimensions & Mechanical Data
Case MaterialV0 according to UL 94

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the HO 25-NPPR.

Extremely low profile 12 mm
AC variable speed and servo motor drives
Single power supply +5 V
Static converters for DC motor drives
Adjustable offset & sensitivity
Battery supplied applications
Adjustable over current detect (default: 2.9 × I peak value)

Characteristic Curves

The characteristic curves of the HO 25-NPPR from the official datasheet are shown below.

HO 25-NPPR characteristic curves
Characteristic curves — source: LEM HO 25-NPPR datasheet
Accuracy & Dynamic Characteristics
Accuracy @ IPN±1.0 % of IPN
Accuracy @ IPN @ TA = +85 °C±3.4 % of IPN
Accuracy @ IPN @ TA = +105 °C±4.2 % of IPN
Sensitivity Error (εG)±0.5 %
Temperature Coefficient of G (TCG)±250 ppm/K
Linearity Error 0 .. IPN (εL)±0.5 % of IPN
Linearity Error 0 .. IPM (εL)±0.8 % of IPM
Temperature Coefficient of Vref (TCVref)±190 ppm/K
Temperature Coefficient of VO E (TCVOE)±0.12 mV/K

Note: Refer to the datasheet for the complete set of characteristic curves.