Your Trusted Source for Industrial Electrical Components

HO 6-P

Hall effect measuring principle

LEM | HO-Series | PCB Mount

6 ANominal Primary Current
4.5 ... 5.5 VPower Supply
250 kHzBandwidth (-3dB)
±1.35 % of IPNOverall Accuracy @ IPN
19 ... 25 mACurrent Consumption (IC)

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range−20 ... 20 A
Reference Voltage (Internal)2.475 ... 2.525 V
Electrical Offset Voltage−10 ... 10 mV
Response Time to 90 % of IPN3.5 µs
Isolation Test Voltage4.3 kV
Operating Temperature Range−40 ... 105 °C

Standards & Approvals

Typical Applications

UNVERIFIED.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Technical Specifications

General Information
ManufacturerLEM
Product SeriesHO
Product ReferenceHO 6-P
Primary Nominal Current6 A
Supply Voltage4.5 ... 5.5 V
Measurementcurrent: DC, AC, pulsed...
MountingPCB Mount
Application DomainIndustrial
Electrical Data — HO 6-P
Primary Nominal RMS Current (IPN)6 A
Primary Current, Measuring Range (IPM)−20 ... 20 A
Supply Voltage (UC)4.5 ... 5.5 V
Current Consumption (IC)19 ... 25 mA
Reference Voltage (Vref, Internal)2.475 ... 2.525 V
External Reference Voltage (Vref)0.5 ... 2.65 V
Output Voltage Range @ IPM (VOUT − Vref)−2 ... 2 V
Electrical Offset Voltage (VO E) @ IP = 0−10 ... 10 mV
Theoretical Sensitivity (Gth)100 mV/A
Accuracy & Dynamic Performance
Accuracy @ IPN±1.35 % of IPN
Accuracy @ IPN @ TA = +85 °C±4.25 % of IPN
Accuracy @ IPN @ TA = +105 °C±5.22 % of IPN
Sensitivity Error (εG)±0.85 %
Temperature Coefficient of G (TCG)±250 ppm/K
Linearity Error 0 .. IPN (εL)±0.5 % of IPN
Linearity Error 0 .. IPM (εL)±0.8 % of IPM
Temperature Coefficient of VO E (TCVOE)±0.14 mV/K
Magnetic Offset Voltage (VOM) after 2.5 × IPN±5 mV
Reaction Time @ 10 % of IPN (tra)2 µs
Response Time @ 90 % of IPN (tr)3.5 µs
Frequency Bandwidth (-3 dB) (BW)250 kHz
Over-Current Detect (peak)2.6 ... 3.2 × IPN (peak)
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud4.3 kV
Impulse Withstand Voltage (1.2/50 µs) UNi8 kV
Partial Discharge Extinction Voltage @ 10 pC (rms) Ue1650 V
Creepage Distance (dCp)8 mm
Clearance (dCI)8 mm
Case MaterialV0 according to UL 94
Comparative Tracking Index (CTI)600
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−40 ... 105 °C
Ambient Storage Temperature (TA st)−40 ... 105 °C
Surrounding Temperature according to UL 508105 °C
Mass (m)10 g
Standards & Certifications
EN 501781997
IEC 61010-12010
IEC 61326-12012
UL 5082010

Note: Specifications are taken from the official HO 6-P datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the HO 6-P are shown below.

HO 6-P outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM HO 6-P datasheet
Outline Dimensions & Mechanical Data
Mass10 g
Case MaterialV0 according to UL 94

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the HO 6-P.

UNVERIFIED

Characteristic Curves

The characteristic curves of the HO 6-P from the official datasheet are shown below.

HO 6-P characteristic curves
Characteristic curves — source: LEM HO 6-P datasheet
Accuracy & Dynamic Characteristics
Theoretical Sensitivity (Gth)100 mV/A
Accuracy @ IPN±1.35 % of IPN
Accuracy @ IPN @ TA = +85 °C±4.25 % of IPN
Accuracy @ IPN @ TA = +105 °C±5.22 % of IPN
Sensitivity Error (εG)±0.85 %
Temperature Coefficient of G (TCG)±250 ppm/K
Linearity Error 0 .. IPN (εL)±0.5 % of IPN
Linearity Error 0 .. IPM (εL)±0.8 % of IPM
Temperature Coefficient of VO E (TCVOE)±0.14 mV/K

Note: Refer to the datasheet for the complete set of characteristic curves.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment