Your Trusted Source for Industrial Electrical Components

HO 60-P-0100

Open loop multi-range current transducer

LEM | HO-Series | Open loop | IEC 61800-1 | PCB Mount

60 ANominal Primary Current
Open loopTechnology
100 kHzBandwidth (-3dB)
−1.25 ... 1.25 % of IPNOverall Accuracy @ IPN
1Number of Primary Turns (NP)

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range−150 ... 150 A
Reference Voltage (output)2.48 ... 2.52 V
Electrical Offset Voltage−5 ... 5 mV
Delay Time to 90 % of Final Output3.5 µs
Isolation Test Voltage4.3 kV
Operating Temperature Range−40 ... 105 °C

Standards & Approvals

  • IEC 61800-1: 1997
  • IEC 61800-2: 2015

Typical Applications

UNVERIFIED.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Technical Specifications

General Information
ManufacturerLEM
Product SeriesHO
Product ReferenceHO 60-P-0100
Primary Nominal Current60 A
Supply Voltage4.5 ... 5.5 V
Measurementcurrent: DC, AC, pulsed...
MountingPCB Mount
Application DomainIndustrial
Electrical Data — HO 60-P-0100
Primary Nominal RMS Current (IPN)60 A
Primary Current, Measuring Range (IPM)−150 ... 150 A
Number of Primary Turns (NP)1
Supply Voltage (UC)4.5 ... 5.5 V
Current Consumption (IC)19 ... 25 mA
Reference Voltage (output) (Uref)2.48 ... 2.52 V
Reference Voltage (input) (Uref)0.5 ... 2.65 V
Output Voltage Range @ IPM (Uout − Uref)−2 ... 2 V
Uref Output Resistance (Rref)130 ... 300 Ω
Uout Output Resistance (Rout)2 ... 5 Ω
Load Capacitance (CL)0 ... 6 nF
OCD Output On Resistance (Ron OCD)70 ... 150 Ω
OCD Output Hold Time (thold)0.7 ... 1.4 ms
EEPROM Control (Uout)0 ... 50 mV
Electrical Offset Voltage @ IP = 0 A (UO E)−5 ... 5 mV
Electrical Offset Current referred to primary (IO E)−0.375 ... 0.375 A
External Detection Threshold Sensitivity (Sth)13.333 mV/A
Accuracy & Dynamic Performance
Sum of Sensitivity and Linearity @ IPN−1.25 ... 1.25 % of IPN
Sum of Sensitivity and Linearity @ IPN @ TA = +85 °C−3.91 ... 3.91 % of IPN
Sum of Sensitivity and Linearity @ IPN @ TA = +105 °C−4.80 ... 4.80 % of IPN
Sensitivity Error @ IPN (εS)−0.5 ... 0.5 %
Temperature Coefficient of S (TCS)−350 ... 350 ppm/K
Linearity Error 0 .. IPN (εL)−0.75 ... 0.75 % of IPN
Linearity Error 0 .. IPM (εL)−0.5 ... 0.5 % of IPM
Temperature Coefficient of Uref (TCUref)−170 ... 170 ppm/K
Temperature Coefficient of UO E (TCUOE)−0.075 ... 0.075 mV/K
Offset Drift referred to primary (TCIO E)−5.625 ... 5.625 mA/K
Magnetic Offset Current @ 10 × IPN (IOM)−0.92 ... 0.92 A
Delay Time to 10 % of Final Output (tD10)2.5 µs
Delay Time to 90 % of Final Output (tD90)3.5 µs
Frequency Bandwidth (-3 dB) (BW)100 kHz
Primary Current Detection Threshold (OCD, peak)2.64 ... 3.22 × IPN (peak)
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud4.3 kV
Impulse Withstand Voltage (1.2/50 µs) UNi8 kV
Partial Discharge Test Voltage (q < 10 pC) Um t1500 V
Creepage Distance (dCp)> 8 mm
Clearance (dCI)> 8 mm
Case MaterialV0 according to UL 94
Comparative Tracking Index (CTI)600
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−40 ... 105 °C
Ambient Storage Temperature (TA st)−40 ... 105 °C
Mass (m)34 g
Standards & Certifications
IEC 61800-11997
IEC 61800-22015
IEC 61800-32004
IEC 61800-5-12007
UL 5082013

Note: Specifications are taken from the official HO 60-P-0100 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the HO 60-P-0100 are shown below.

HO 60-P-0100 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM HO 60-P-0100 datasheet
Outline Dimensions & Mechanical Data
Mass34 g
Case MaterialV0 according to UL 94

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the HO 60-P-0100.

UNVERIFIED

Characteristic Curves

The characteristic curves of the HO 60-P-0100 from the official datasheet are shown below.

HO 60-P-0100 characteristic curves
Characteristic curves — source: LEM HO 60-P-0100 datasheet
Accuracy & Dynamic Characteristics
External Detection Threshold Sensitivity (Sth)13.333 mV/A
Sum of Sensitivity and Linearity @ IPN−1.25 ... 1.25 % of IPN
Sum of Sensitivity and Linearity @ IPN @ TA = +85 °C−3.91 ... 3.91 % of IPN
Sum of Sensitivity and Linearity @ IPN @ TA = +105 °C−4.80 ... 4.80 % of IPN
Sensitivity Error @ IPN (εS)−0.5 ... 0.5 %
Temperature Coefficient of S (TCS)−350 ... 350 ppm/K
Linearity Error 0 .. IPN (εL)−0.75 ... 0.75 % of IPN
Linearity Error 0 .. IPM (εL)−0.5 ... 0.5 % of IPM
Temperature Coefficient of Uref (TCUref)−170 ... 170 ppm/K

Note: Refer to the datasheet for the complete set of characteristic curves.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment