Your Trusted Source for Industrial Electrical Components

HOP 800-SB

Open loop Hall effect transducer

LEM | HOP-Series | Open loop | EN 50178 | Panel Mount

15 VPower Supply
Open loopTechnology
DC ... 10 kHzBandwidth (-1dB)
±1 %Linearity Error (Max)
5 kVRMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud

Additional Technical Details

View Full Specifications
Supply Voltage15 V
Accuracy @ IPN±5 %
Operating Temperature Range−10 ... +70 °C
Isolation Test Voltage5 kV
Current Consumption (IC)20 mA
Accuracy @ IPN, TA = 25 °C, ±15 V±5 %

Standards & Approvals

  • EN 50178
  • UL 508

Typical Applications

Power supplies for TELECOM (monitoring & measuring), Uninterruptible Power Supplies (UPS), Switched Mode Power Supplies (SMPS), Electrical chemistry, Chopper, Battery supplied applications.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The HOP 800-SB is an open loop current transducer from LEM for the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation.

Typical applications include Power supplies for TELECOM (monitoring & measuring), Uninterruptible Power Supplies (UPS), Switched Mode Power Supplies (SMPS) and Electrical chemistry.

Key characteristics from the official datasheet: linearity error ±1 %; frequency bandwidth DC ... 10 kHz; operating temperature −10 ... +70 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesHOP
Product ReferenceHOP 800-SB
Supply Voltage15 V
Measurementcurrents: DC, AC, pulsed...
MountingPanel Mount
Application DomainIndustrial
Electrical Data — HOP 800-SB
Supply Voltage (UC)15 V
Current Consumption (IC)20 mA
Accuracy & Dynamic Performance
Accuracy @ IPN, TA = 25 °C, ±15 V±5 %
Linearity Error (εL) (0 ... ±IPN)±1 %
Frequency Bandwidth (−3 dB)DC ... 10 kHz
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud5 kV
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−10 ... +70 °C
Ambient Storage Temperature (TA st)−25 ... +85 °C
Mass (m)590 g
Case MaterialInsulating plastic case recognized according to UL 94-V0.
General Tolerance±1 mm
Standards & Certifications
EN 50178Compliance
UL 508Compliance

Note: Specifications are taken from the official HOP 800-SB datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the HOP 800-SB are shown below.

HOP 800-SB outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM HOP 800-SB datasheet, page 3
Outline Dimensions & Mechanical Data
General Tolerance±1 mm
Mass590 g
Case MaterialInsulating plastic case recognized according to UL 94-V0.

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the HOP 800-SB.

Power supplies for TELECOM (monitoring & measuring)
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Electrical chemistry
Chopper
Battery supplied applications

Characteristic Curves

Characteristic curve diagrams are not included in the HOP 800-SB datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Accuracy & Dynamic Characteristics
Accuracy @ IPN, TA = 25 °C, ±15 V±5 %
Linearity Error (εL) (0 ... ±IPN)±1 %
Frequency Bandwidth (−3 dB)DC ... 10 kHz

Note: For the full set of performance data, refer to the datasheet.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment