HSNBV-D05

Ratiometric transducer

LEM | HSN-Series | Open Loop Transducer | Busbar Mount

± 50 A / ± 400 A / ± 50 A / ± 300 ANominal Primary Current
4.75 .. 5.25 VPower Supply
Open Loop TransducerTechnology
1100 HzBandwidth (-1dB)
± 0.5 %Linearity Error (Max)

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range± 50 A / ± 400 A / ± 50 A / ± 300 A
Supply Voltage4.75 .. 5.25 V
Sensitivity40 / 5 / 6.67 mV/A
Operating Temperature Range−40 .. 125 °C
Isolation Test Voltage2.5 kV
Primary Nominal Current (IPN)± 50 A / ± 400 A / ± 50 A / ± 300 A

Standards & Approvals

Typical Applications

(*) Dual channel transducer for wider measurement range Hall P a constant (D) or redundancy (R). b constant.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The HSNBV-D05 is an open loop current transducer from LEM for the electronic measurement of DC, AC or pulsed currents, with galvanic isolation, delivering a output noise of 10 mV.

It offers excellent accuracy and very good linearity. Typical applications include (*) Dual channel transducer for wider measurement range Hall P a constant (D) or redundancy (R). b constant.

Key characteristics from the official datasheet: linearity error ± 0.5 %; frequency bandwidth 1100 Hz; operating temperature −40 .. 125 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesHSN
Product ReferenceHSNBV-D05
Primary Nominal Current± 50 A / ± 400 A / ± 50 A / ± 300 A
Supply Voltage4.75 .. 5.25 V
MeasurementDC, AC or pulsed currents
MountingBusbar Mount
Application Domain(*) Dual channel transducer for wider measurement range Hall P a constant (D) or redundancy (R). b constant
Electrical Data — HSNBV-D05
Primary Nominal Current (IPN)± 50 A / ± 400 A / ± 50 A / ± 300 A
Primary Current, Measuring Range (IPM)± 50 A / ± 400 A / ± 50 A / ± 300 A
Supply Voltage (UC)4.75 .. 5.25 V
Current Consumption (IC)18 mA
Sensitivity40 / 5 / 6.67 mV/A
Load Resistance (RL)10 kOhm
Insulation Resistance (RINS)500 MOhm
Accuracy & Dynamic Performance
Ratiometricity Error± 0.3 %
Sensitivity Error± 1 %
Linearity Error± 0.5 %
Delay Time (tD)10 ms
Frequency Bandwidth1100 Hz
Output Noise10 mV
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud2.5 kV
Creepage Distance (dCp)5.12 mm
Clearance (dCI)5.12 mm
Comparative Tracking Index (CTI)PLC0 ≥ 600 V
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−40 .. 125 °C
Ambient Storage Temperature (TA st)−40 .. 125 °C
Mass (m)41 g

Note: Specifications are taken from the official HSNBV-D05 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the HSNBV-D05 are shown below.

HSNBV-D05 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM HSNBV-D05 datasheet
Outline Dimensions & Mechanical Data
Mass41 g

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the HSNBV-D05.

(*) Dual channel transducer for wider measurement range Hall P a constant (D) or redundancy (R). b constant

Characteristic Curves

The characteristic curves of the HSNBV-D05 from the official datasheet are shown below.

HSNBV-D05 characteristic curves
Characteristic curves — source: LEM HSNBV-D05 datasheet
Accuracy & Dynamic Characteristics
Sensitivity40 / 5 / 6.67 mV/A
Sensitivity Error± 1 %
Linearity Error± 0.5 %
Frequency Bandwidth1100 Hz
Reference Conditions
Ambient Temperature (TA)25 °C, unless otherwise noted
Output Load Resistance (RL)10 kOhm

Note: Refer to the datasheet for the complete set of characteristic curves.