Authorized Distributor
?
Hall effect measuring principle
| Operating Temperature Range | −40 ... +80 °C |
| Isolation Test Voltage | 2.5 kV |
| Current Consumption (IC) | 15 mA |
| Insulation Resistance (RINS) | > 500 MΩ |
| Frequency Bandwidth (−3 dB) | DC … 50 kHz |
| RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud | 2.5 kV |
AC variable speed drives and servo motor drives, Static converters for DC motor drives, Battery supplied applications, Uninterruptible Power Supplies (UPS), Switched Mode Power Supplies (SMPS), Power supplies for welding applications.
The HTB 100-P is a None current transducer from LEM for the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation.
Typical applications include AC variable speed drives and servo motor drives, Static converters for DC motor drives, Battery supplied applications and Uninterruptible Power Supplies (UPS).
Key characteristics from the official datasheet: linearity error ±1 %; frequency bandwidth DC … 50 kHz; operating temperature −40 ... +80 °C.
| General Information | |
|---|---|
| Manufacturer | LEM |
| Product Series | HTB |
| Product Reference | HTB 100-P |
| Measurement | currents: DC, AC, pulsed... |
| Mounting | Busbar Mount |
| Application Domain | Industrial |
| Electrical Data — HTB 100-P | |
|---|---|
| Current Consumption (IC) | 15 mA |
| Insulation Resistance (RINS) | > 500 MΩ |
| Accuracy & Dynamic Performance | |
|---|---|
| Linearity Error (εL) (0 ... ±IPN) | ±1 % |
| Frequency Bandwidth (−3 dB) | DC … 50 kHz |
| Insulation Coordination | |
|---|---|
| RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud | 2.5 kV |
| Environmental & Mechanical Characteristics | |
|---|---|
| Ambient Operating Temperature (TA) | −40 ... +80 °C |
| Ambient Storage Temperature (TA st) | −40 ... +85 °C |
| Case Material | Insulating plastic case recognized according to UL 94-V0. |
| General Tolerance | ±0.5 mm |
| Standards & Certifications | |
|---|---|
| EN 50178 | Compliance |
Note: Specifications are taken from the official HTB 100-P datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.
Official technical documentation for the HTB 100-P.
Outline dimensions, pin layout and connection diagrams of the HTB 100-P are shown below.
| Outline Dimensions & Mechanical Data | |
|---|---|
| General Tolerance | ±0.5 mm |
| Case Material | Insulating plastic case recognized according to UL 94-V0. |
Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.
Typical applications of the HTB 100-P.
Characteristic curve diagrams are not included in the HTB 100-P datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.
| Accuracy & Dynamic Characteristics | |
|---|---|
| Linearity Error (εL) (0 ... ±IPN) | ±1 % |
| Frequency Bandwidth (−3 dB) | DC … 50 kHz |