Your Trusted Source for Industrial Electrical Components

HTB 100-TP

Hall effect measuring principle

LEM | HTB-Series | EN 50178 | Busbar Mount

DC … 50 kHzBandwidth (-1dB)
±1 %Linearity Error (Max)
−40 ... +80 °CAmbient Operating Temperature (TA)
−40 ... +85 °CAmbient Storage Temperature (TA st)
Insulating plastic case recognized according to UL 94-V0.Case Material

Additional Technical Details

View Full Specifications
Operating Temperature Range−40 ... +80 °C
Isolation Test Voltage2.5 kV
Current Consumption (IC)15 mA
Insulation Resistance (RINS)> 500 MΩ
Frequency Bandwidth (−3 dB)DC … 50 kHz
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud2.5 kV

Standards & Approvals

  • EN 50178

Typical Applications

AC variable speed drives and servo motor drives, Static converters for DC motor drives, Battery supplied applications, Uninterruptible Power Supplies (UPS), Switched Mode Power Supplies (SMPS), Power supplies for welding applications.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The HTB 100-TP is a None current transducer from LEM for the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation.

Typical applications include AC variable speed drives and servo motor drives, Static converters for DC motor drives, Battery supplied applications and Uninterruptible Power Supplies (UPS).

Key characteristics from the official datasheet: linearity error ±1 %; frequency bandwidth DC … 50 kHz; operating temperature −40 ... +80 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesHTB
Product ReferenceHTB 100-TP
Measurementcurrents: DC, AC, pulsed...
MountingBusbar Mount
Application DomainIndustrial
Electrical Data — HTB 100-TP
Current Consumption (IC)15 mA
Insulation Resistance (RINS)> 500 MΩ
Accuracy & Dynamic Performance
Linearity Error (εL) (0 ... ±IPN)±1 %
Frequency Bandwidth (−3 dB)DC … 50 kHz
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud2.5 kV
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−40 ... +80 °C
Ambient Storage Temperature (TA st)−40 ... +85 °C
Case MaterialInsulating plastic case recognized according to UL 94-V0.
General Tolerance±0.5 mm
Standards & Certifications
EN 50178Compliance

Note: Specifications are taken from the official HTB 100-TP datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the HTB 100-TP are shown below.

HTB 100-TP outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM HTB 100-TP datasheet, page 3
Outline Dimensions & Mechanical Data
General Tolerance±0.5 mm
Case MaterialInsulating plastic case recognized according to UL 94-V0.

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the HTB 100-TP.

AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications

Characteristic Curves

Characteristic curve diagrams are not included in the HTB 100-TP datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Accuracy & Dynamic Characteristics
Linearity Error (εL) (0 ... ±IPN)±1 %
Frequency Bandwidth (−3 dB)DC … 50 kHz

Note: For the full set of performance data, refer to the datasheet.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment