LEM | HTRS-Series | Open loop current transducer | EN 50121-4 | Panel Mount

50 ANominal Primary Current
11.5 ... 26 VPower Supply
Open loop current transducerTechnology
30 KHzBandwidth (-1dB)
−0.5 ... 0.5 % of IPNLinearity Error (Max)

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range−100 ... 100 A
Supply Voltage11.5 ... 26 V
Operating Temperature Range−40 ... 85 °C
Isolation Test Voltage6 kV
Primary Nominal RMS Current (IPN)50 A
Current Consumption (IC)50 mA

Standards & Approvals

  • EN 50121-4 : 2015 1)
  • EN 50124-1
  • EN 50125-3 : 2003

Typical Applications

UL508 : 2010, EN 50121-4 : 2015 1), EN 50124-1 : 2017, EN 50125-3 : 2003. Application Domain, Track side. Note: according to EN 61000-4-3, is used shield wire with both ends.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The HTRS 50 -SBI 4-20mA inst. is an open loop current transducer from LEM for the electronic measurement of current: DC, AC, pulsed..., with galvanic isolation.

Typical applications include UL508 : 2010, EN 50121-4 : 2015 1), EN 50124-1 : 2017 and EN 50125-3 : 2003. Application Domain.

Key characteristics from the official datasheet: linearity error −0.5 ... 0.5 % of IPN; frequency bandwidth 30 KHz; operating temperature −40 ... 85 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesHTRS
Product ReferenceHTRS 50 -SBI 4-20mA inst.
Primary Nominal Current50 A
Supply Voltage11.5 ... 26 V
Measurementcurrent: DC, AC, pulsed...
MountingPanel Mount
Application DomainTrack side
Electrical Data — HTRS 50 -SBI 4-20mA inst.
Primary Nominal RMS Current (IPN)50 A
Primary Current, Measuring Range (IPM)−100 ... 100 A
Supply Voltage (UC)11.5 ... 26 V
Current Consumption (IC)50 mA
Accuracy & Dynamic Performance
Linearity Error (εL)−0.5 ... 0.5 % of IPN
Response Time to 90 % of IPN Step20 µs
Frequency Bandwidth30 KHz
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud6 kV
Impulse Withstand Voltage (1.2/50 µs) UNi11 kV
Creepage Distance (dCp)12.7 mm
Clearance (dCI)12.7 mm
Comparative Tracking Index (CTI)250
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−40 ... 85 °C
Ambient Storage Temperature (TA st)−40 ... 85 °C
Mass (m)35 g
Standards & Certifications
EN 50121-4: 2015 1)
EN 50124-1:
EN 50125-3: 2003.

Note: Specifications are taken from the official HTRS 50 -SBI 4-20mA inst. datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the HTRS 50 -SBI 4-20mA inst. are shown below.

HTRS 50 -SBI  4-20mA inst. outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM HTRS 50 -SBI 4-20mA inst. datasheet
Outline Dimensions & Mechanical Data
Mass35 g

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the HTRS 50 -SBI 4-20mA inst.

UL508 : 2010
EN 50121-4 : 2015 1)
EN 50124-1 : 2017
EN 50125-3 : 2003. Application Domain
Track side. Note: according to EN 61000-4-3, is used shield wire with both ends Page 1/12 LEM International SA right to carry out modifications on its transducers, Route du Nant-d’Avril, 152 them. www.lem.com

Characteristic Curves

The characteristic curves of the HTRS 50 -SBI 4-20mA inst. from the official datasheet are shown below.

HTRS 50 -SBI  4-20mA inst. characteristic curves
Characteristic curves — source: LEM HTRS 50 -SBI 4-20mA inst. datasheet
Accuracy & Dynamic Characteristics
Linearity Error (εL)−0.5 ... 0.5 % of IPN
Response Time to 90 % of IPN Step20 µs
Frequency Bandwidth30 KHz

Note: Refer to the datasheet for the complete set of characteristic curves.