Your Trusted Source for Industrial Electrical Components
Home Products LEM High Precision Series IT Series ITC 4000-S/SP2

ITC 4000-S/SP2

fluxgate

LEM | ITC-Series | fluxgate | EN 50124-1 | Busbar Mount

4000 ANominal Primary Current
±21.6 .. ±24 VPower Supply
fluxgateTechnology
45 kHzBandwidth (-1dB)
± ... % (85 °C) / ± ... % (85 °C) / ± ... % (85 °C) / ± 0.2 % (23 °C) / ± 0.4 % (23 °C) / ± 2 % (23 °C)Total Error @ IPN

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range0 .. ± 6000 A
Secondary Nominal Current1.6 A
Supply Voltage±21.6 .. ±24 V
Isolation Test Voltage14 kV
Primary Nominal RMS Current (IPN)4000 A
Secondary Nominal RMS Current (ISN)1.6 A

Standards & Approvals

  • EN 50124-1: 2017

Typical Applications

UNVERIFIED.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The ITC 4000-S/SP2 is a fluxgate current transducer from LEM for the electronic measurement of current: DC, AC, pulsed..., with galvanic isolation.

It offers low temperature drift. Typical applications include UNVERIFIED.

Key characteristics from the official datasheet: total error ± ... % (85 °C) / ± ... % (85 °C) / ± ... % (85 °C) / ± 0.2 % (23 °C) / ± 0.4 % (23 °C) / ± 2 % (23 °C); linearity error ± 0.0004 %; frequency bandwidth 45 kHz; nominal secondary output 1.6 A.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesITC
Product ReferenceITC 4000-S/SP2
Primary Nominal Current4000 A
Supply Voltage±21.6 .. ±24 V
Measurementcurrent: DC, AC, pulsed...
MountingBusbar Mount
Application DomainRailway (fixed installations and onboard)
Electrical Data — ITC 4000-S/SP2
Primary Nominal RMS Current (IPN)4000 A
Primary Current, Measuring Range (IPM)0 .. ± 6000 A
Secondary Nominal RMS Current (ISN)1.6 A
Turns Ratio (NP/NS)1 : 2500
Supply Voltage (UC)±21.6 .. ±24 V
Current Consumption (IC)45 mA @ ±UC = ±24 V
Accuracy & Dynamic Performance
Total Error (εtot) @ IPN± ... % (85 °C) / ± ... % (85 °C) / ± ... % (85 °C) / ± 0.2 % (23 °C) / ± 0.4 % (23 °C) / ± 2 % (23 °C)
Linearity Error (εL)± 0.0004 %
Frequency Bandwidth (BW)45 kHz
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud14 kV
Impulse Withstand Voltage (1.2/50 µs) UNi30 kV
Comparative Tracking Index (CTI)600
Environmental & Mechanical Characteristics
Case MaterialV0 according to UL 94
Standards & Certifications
EN 50124-12017

Note: Specifications are taken from the official ITC 4000-S/SP2 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the ITC 4000-S/SP2 are shown below.

ITC 4000-S/SP2 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM ITC 4000-S/SP2 datasheet
Outline Dimensions & Mechanical Data
Case MaterialV0 according to UL 94

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the ITC 4000-S/SP2.

UNVERIFIED

Characteristic Curves

The characteristic curves of the ITC 4000-S/SP2 from the official datasheet are shown below.

ITC 4000-S/SP2 characteristic curves
Characteristic curves — source: LEM ITC 4000-S/SP2 datasheet
Accuracy & Dynamic Characteristics
Total Error (εtot) @ IPN± ... % (85 °C) / ± ... % (85 °C) / ± ... % (85 °C) / ± 0.2 % (23 °C) / ± 0.4 % (23 °C) / ± 2 % (23 °C)
Linearity Error (εL)± 0.0004 %
Frequency Bandwidth (BW)45 kHz

Note: Refer to the datasheet for the complete set of characteristic curves.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment