Your Trusted Source for Industrial Electrical Components

ITN 12-P

Closed loop (compensated) current transducer using an extremely accurate zero flux detector

LEM | ITN-Series | Closed loop (compensated) | PCB Mount

8.8 ANominal Primary Current
±15 VPower Supply
Closed loop (compensated)Technology
±15 V ≤ 60 + I mACurrent Consumption (IC)
4.3 kVImpulse Withstand Voltage (1.2/50 µs) UNi

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range(peak limit
Secondary Nominal Current35 mA
Supply Voltage±15 V
Operating Temperature Range+10 … +45 °C
Primary Nominal RMS Current (IPN)8.8 A
Secondary Nominal RMS Current (ISN)35 mA

Standards & Approvals

Typical Applications

Feed back element in precision current regulated devices (power ... 80 % supplies...), Calibration unit, Precise and high-stability, Energy measurement, Medical equipment.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The ITN 12-P is a closed loop (compensated) current transducer from LEM for the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation.

It offers excellent accuracy, very good linearity, low temperature drift and wide frequency bandwidth. Typical applications include Feed back element in precision current regulated devices (power ... 80 % supplies...), Calibration unit, Precise and high-stability and Energy measurement.

Key characteristics from the official datasheet: operating temperature +10 … +45 °C; nominal secondary output 35 mA.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesITN
Product ReferenceITN 12-P
Primary Nominal Current8.8 A
Supply Voltage±15 V
Measurementcurrents: DC, AC, pulsed...
MountingPCB Mount
Application DomainIndustrial and Medical
Electrical Data — ITN 12-P
Primary Nominal RMS Current (IPN)8.8 A
Primary Current, Measuring Range (IPM)(peak limit
Secondary Nominal RMS Current (ISN)35 mA
Supply Voltage (UC)±15 V
Current Consumption (IC)±15 V ≤ 60 + I mA
Insulation Coordination
Impulse Withstand Voltage (1.2/50 µs) UNi4.3 kV
Creepage Distance (dCp)4.7 mm
Clearance (dCI)3.3 mm
Comparative Tracking Index (CTI)175
Overvoltage Category / Pollution DegreeOver voltage category III · Pollution degree 2
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)+10 … +45 °C
Ambient Storage Temperature (TA st)−20 … +85 °C

Note: Specifications are taken from the official ITN 12-P datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the ITN 12-P are shown below.

ITN 12-P outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM ITN 12-P datasheet, page 1

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the ITN 12-P.

Feed back element in precision current regulated devices (power ... 80 % supplies...)
Calibration unit
Precise and high-stability
Energy measurement
Medical equipment

Characteristic Curves

Characteristic curve diagrams are not included in the ITN 12-P datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Note: For the full set of performance data, refer to the datasheet.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment