Authorized Distributor
?
Closed loop (compensated) current transducer using the Hall effect
| Primary Current, Measuring Range | 0 … ±200 A |
| Secondary Nominal Current | 125 mA |
| Supply Voltage | ±12 … 15 V |
| Operating Temperature Range | −40 … +85 °C |
| Isolation Test Voltage | 3 kV |
| Primary Nominal RMS Current (IPN) | 125 A |
AC variable speed drives and servo motor drives, Static converters for DC motor drives, Battery supplied applications, Uninterruptible Power Supplies (UPS), Switched Mode Power Supplies (SMPS), Power supplies for welding applications.
The LA 125-P is a closed loop (compensated) current transducer from LEM for the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation.
It offers excellent accuracy, very good linearity, low temperature drift and wide frequency bandwidth. Typical applications include AC variable speed drives and servo motor drives, Static converters for DC motor drives, Battery supplied applications and Uninterruptible Power Supplies (UPS).
Key characteristics from the official datasheet: linearity error < 0.15 %; frequency bandwidth (−1 dB) DC … 100 kHz; operating temperature −40 … +85 °C; nominal secondary output 125 mA.
| General Information | |
|---|---|
| Manufacturer | LEM |
| Product Series | LA |
| Product Reference | LA 125-P |
| Primary Nominal Current | 125 A |
| Supply Voltage | ±12 … 15 V |
| Measurement | currents: DC, AC, pulsed... |
| Mounting | PCB Mount |
| Application Domain | Industrial |
| Electrical Data — LA 125-P | |
|---|---|
| Primary Nominal RMS Current (IPN) | 125 A |
| Primary Current, Measuring Range (IPM) | 0 … ±200 A |
| Secondary Nominal RMS Current (ISN) | 125 mA |
| Turns Ratio (NP/NS) | 1 : 1000 |
| Supply Voltage (UC) | ±12 … 15 V |
| Current Consumption (IC) | 16 (@ ±15 V) + I mA |
| Accuracy & Dynamic Performance | |
|---|---|
| Linearity Error (εL) | < 0.15 % |
| Frequency Bandwidth (BW) | (−1 dB) DC … 100 kHz |
| Insulation Coordination | |
|---|---|
| RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud | 3 kV |
| Impulse Withstand Voltage (1.2/50 µs) UNi | 7 kV |
| Creepage Distance (dCp) | 6.7 mm |
| Clearance (dCI) | 6.7 mm |
| Rated Insulation Voltage (basic) | 600 V |
| Rated Insulation Voltage (reinforced) | 300 V |
| Overvoltage Category / Pollution Degree | Over voltage category OV · Pollution degree PD2 |
| Environmental & Mechanical Characteristics | |
|---|---|
| Ambient Operating Temperature (TA) | −40 … +85 °C |
| Ambient Storage Temperature (TA st) | −40 … +90 °C |
| Mass (m) | 40 g |
| Case Material | Insulating plastic case recognized according to UL 94-V0. |
| Recommended PCB Hole | 0.9 mm |
| General Tolerance | ±0.2 mm |
| Standards & Certifications | |
|---|---|
| EN 50178 | Compliance |
Note: Specifications are taken from the official LA 125-P datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.
Official technical documentation for the LA 125-P.
Outline dimensions, pin layout and connection diagrams of the LA 125-P are shown below.
| Outline Dimensions & Mechanical Data | |
|---|---|
| Recommended PCB Hole | 0.9 mm |
| General Tolerance | ±0.2 mm |
| Mass | 40 g |
| Case Material | Insulating plastic case recognized according to UL 94-V0. |
Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.
Typical applications of the LA 125-P.
Characteristic curve diagrams are not included in the LA 125-P datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.
| Accuracy & Dynamic Characteristics | |
|---|---|
| Linearity Error (εL) | < 0.15 % |
| Frequency Bandwidth (BW) | (−1 dB) DC … 100 kHz |
Note: For the full set of performance data, refer to the datasheet.