Your Trusted Source for Industrial Electrical Components
Home Products LEM Industrial Drive, Welding & New Energy Power Supply LAC Series LAC 300-S/SP10 Cable output (600 mm)

LAC 300-S/SP10 Cable output (600 mm)

Closed loop (compensated) current transducer using the Hall effect

LEM | LAC-Series | Closed loop (compensated) | 2) EN 50155 | Busbar Mount

300 ANominal Primary Current
±24 VPower Supply
Closed loop (compensated)Technology
DC ... 50 kHzBandwidth (-1dB)
±1.4 %Total Error @ IPN

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range@ 85 °C 0 ..
Secondary Nominal Current60 mA
Supply Voltage±24 V
Operating Temperature Range−40 ... +85 °C
Isolation Test Voltage5.5 kV
Primary Nominal RMS Current (IPN)300 A

Standards & Approvals

  • 2) EN 50155
  • UL 508
  • EN 50121-3-2

Typical Applications

Single or three phases inverters, Propulsion and braking choppers, Propulsion converters, Auxiliary converters, Battery chargers. Application Domain, Railway (fixed installations and onboard).

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The LAC 300-S/SP10 Cable output (600 mm) is a closed loop (compensated) current transducer from LEM for the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation.

It offers excellent accuracy, very good linearity, low temperature drift and wide frequency bandwidth. Typical applications include Single or three phases inverters, Propulsion and braking choppers, Propulsion converters and Auxiliary converters.

Key characteristics from the official datasheet: total error ±1.4 %; linearity error < 0.1 %; frequency bandwidth DC ... 50 kHz; operating temperature −40 ... +85 °C; nominal secondary output 60 mA.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesLAC
Product ReferenceLAC 300-S/SP10 Cable output (600 mm)
Primary Nominal Current300 A
Supply Voltage±24 V
Measurementcurrents: DC, AC, pulsed...
MountingBusbar Mount
Application DomainRailway (fixed installations and onboard)
Electrical Data — LAC 300-S/SP10 Cable output (600 mm)
Primary Nominal RMS Current (IPN)300 A
Primary Current, Measuring Range (IPM)@ 85 °C 0 ..
Secondary Nominal RMS Current (ISN)60 mA
Turns Ratio (NP/NS)1 : 5000
Supply Voltage (UC)±24 V
Current Consumption (IC)I P 25+ I S I mS A R M
Accuracy & Dynamic Performance
Total Error (εtot) @ IPN±1.4 %
Linearity Error (εL)< 0.1 %
Frequency Bandwidth (BW)DC ... 50 kHz
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud5.5 kV
Creepage Distance (dCp)23.7 mm
Clearance (dCI)14 mm
Comparative Tracking Index (CTI)600
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−40 ... +85 °C
Ambient Storage Temperature (TA st)−45 ... +90 °C
Mass (m)175 g
Case MaterialInsulating plastic case recognized according to UL 94-V0.
General Tolerance±0.5 mm
Standards & Certifications
2) EN 50155:
UL 508Compliance
EN 50121-3-2Compliance

Note: Specifications are taken from the official LAC 300-S/SP10 Cable output (600 mm) datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Documents & Downloads

Official technical documentation for the LAC 300-S/SP10 Cable output (600 mm).

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the LAC 300-S/SP10 Cable output (600 mm) are shown below.

LAC 300-S/SP10  Cable output (600 mm) outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM LAC 300-S/SP10 Cable output (600 mm) datasheet
Outline Dimensions & Mechanical Data
General Tolerance±0.5 mm
Mass175 g
Case MaterialInsulating plastic case recognized according to UL 94-V0.

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the LAC 300-S/SP10 Cable output (600 mm).

Single or three phases inverters
Propulsion and braking choppers
Propulsion converters
Auxiliary converters
Battery chargers. Application Domain
Railway (fixed installations and onboard). Page 1/3 LEM International SA Chemin des Aulx 8 www.lem.com

Characteristic Curves

Characteristic curve diagrams are not included in the LAC 300-S/SP10 Cable output (600 mm) datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Accuracy & Dynamic Characteristics
Total Error (εtot) @ IPN±1.4 %
Linearity Error (εL)< 0.1 %
Frequency Bandwidth (BW)DC ... 50 kHz

Note: For the full set of performance data, refer to the datasheet.