Your Trusted Source for Industrial Electrical Components

T0-2-8900/E

On-off switch

Eaton | Switches & Cam Switches | 207398

11.5 AAmperage
690 VVoltage
100 ABreaking Capacity
5.5 kWRated Power
On-off switchProduct Type

Additional Technical Details

View Full Specifications
Product Weight0.108 kg
Product Length/Depth86 mm
Product Height48 mm
Product Width48 mm
Degree Of ProtectionNEMA 12
Number Of Poles4

Standards & Approvals

  • Eaton global quality standards

Typical Applications

Machine Control, Panel Isolation, Position Sensing and more.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Technical Specifications

General Information
Product NameEaton Moeller® series T0 On-off switch
Catalog Number207398
Model CodeT0-2-8900/E
EAN4015082073985
Global Catalog207398
Product TypeOn-off switch
Product CategoryOn-Off switch
Electrical connection type of main circuitScrew connection
Actuator typeShort thumb-grip
Electrical Characteristics
10.11 Short-circuit ratingIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.2.2 Corrosion resistanceMeets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiationUV resistance only in connection with protective shield.
10.9.2 Power-frequency electric strengthIs the panel builder's responsibility.
10.9.3 Impulse withstand voltageIs the panel builder's responsibility.
Operating frequency1200 Operations/h
Rated impulse withstand voltage (Uimp)6000 V AC
Rated operational power star-delta at 500 V, 50 Hz7.5 kW
Rated operational power star-delta at 690 V, 50 Hz5.5 kW
Rated permanent current at AC-21, 400 V20 A
Rated permanent current at AC-23, 400 V13.3 A
Rated uninterrupted current (Iu)20 A
Static heat dissipation, non-current-dependent Pvs0 W
Switching power at 400 V5.5 kW
Voltage per contact pair in series60 V
Rated operational power at AC-3, 500 V, 50 Hz5.5 kW
Rated short-time withstand current (Icw)0.32 kA 320 A, Contacts, 1 second
Assigned motor power at 115/120 V, 60 Hz, 1-phase0.5 HP
Assigned motor power at 200/208 V, 60 Hz, 1-phase1 HP
Assigned motor power at 200/208 V, 60 Hz, 3-phase3 HP
Assigned motor power at 230/240 V, 60 Hz, 1-phase1.5 HP
Assigned motor power at 230/240 V, 60 Hz, 3-phase3 HP
Assigned motor power at 460/480 V, 60 Hz, 3-phase7.5 HP
Assigned motor power at 575/600 V, 60 Hz, 3-phase7.5 HP
Equipment heat dissipation, current-dependent Pvid0.6 W
Heat dissipation capacity Pdiss0 W
Heat dissipation per pole, current-dependent Pvid0.6 W
Rated conditional short-circuit current (Iq)6 kA
Overvoltage categoryIII
Safe isolation440 V AC, Between the contacts, According to EN 61140
Shock resistance15 g, Mechanical, According to IEC/EN 60068-2-27, Half-sinusoidal shock 20 ms
Lifespan, mechanical400,000 Operations
Switching capacity (auxiliary contacts, general use)10A, IU, (UL/CSA)
Switching capacity (auxiliary contacts, pilot duty)P300 (UL/CSA) A600 (UL/CSA)
Switching capacity (main contacts, general use)16 A, Rated uninterrupted current max. (UL/CSA)
Rated breaking capacity at 220/230 V (cos phi to IEC 60947-3)100 A
Rated breaking capacity at 400/415 V (cos phi to IEC 60947-3)110 A
Rated breaking capacity at 500 V (cos phi to IEC 60947-3)80 A
Rated breaking capacity at 660/690 V (cos phi to IEC 60947-3)60 A
Rated making capacity up to 690 V (cos phi to IEC/EN 60947-3)130 A
Rated operating voltage (Ue) - max690 V
Rated operating voltage (Ue) - min690 V
Rated operational voltage (Ue) at AC - max690 V
Short-circuit current rating (basic rating)5 kA, SCCR (UL/CSA) 50A, max. Fuse, SCCR (UL/CSA)
Short-circuit current rating (high fault)20 A, Class J, max. Fuse, SCCR (UL/CSA) 10 kA, SCCR (UL/CSA)
Short-circuit protection rating20 A gG/gL, Fuse, Contacts
Rated operational current (Ie) at AC-21, 440 V20 A
Rated operational current (Ie) at AC-23A, 230 V13.3 A
Rated operational current (Ie) at AC-23A, 400 V, 415 V13.3 A
Rated operational current (Ie) at AC-23A, 500 V13.3 A
Rated operational current (Ie) at AC-23A, 690 V7.6 A
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V11.5 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V11.5 A
Rated operational current (Ie) at AC-3, 500 V9 A
Rated operational current (Ie) at AC-3, 660 V, 690 V4.9 A
Rated operational current (Ie) at DC-1, load-break switches l/r = 1 ms10 A
Rated operational current (Ie) at DC-13, control switches L/R = 50 ms10 A
Rated operational current (Ie) at DC-21, 240 V1 A
Rated operational current (Ie) at DC-23A, 120 V5 A
Rated operational current (Ie) at DC-23A, 24 V10 A
Rated operational current (Ie) at DC-23A, 240 V5 A
Rated operational current (Ie) at DC-23A, 48 V10 A
Rated operational current (Ie) at DC-23A, 60 V10 A
Rated operational current (Ie) star-delta at AC-3, 220/230 V20 A
Rated operational current (Ie) star-delta at AC-3, 380/400 V20 A
Rated operational current (Ie) star-delta at AC-3, 500 V15.6 A
Rated operational current (Ie) star-delta at AC-3, 690 V8.5 A
Rated operational current for specified heat dissipation (In)20 A
Rated operational power at AC-23A, 220/230 V, 50 Hz3 kW
Rated operational power at AC-23A, 400 V, 50 Hz5.5 kW
Rated operational power at AC-23A, 500 V, 50 Hz7.5 kW
Rated operational power at AC-23A, 690 V, 50 Hz5.5 kW
Rated operational power at AC-3, 380/400 V, 50 Hz5.5 kW
Rated operational power at AC-3, 415 V, 50 Hz5.5 kW
Rated operational power at AC-3, 690 V, 50 Hz4 kW
Rated operational power star-delta at 220/230 V, 50 Hz5.5 kW
Rated operational power star-delta at 380/400 V, 50 Hz7.5 kW
Uninterrupted currentRated uninterrupted current Iu is specified for max. cross-section.
Rated Switching Capacity0.5 HP at 120 V AC, single-phase 1 HP at 200 V AC, single-phase 1.5 HP at 240 V AC, single-phase 3 HP at 200 V AC, three-phase 3 HP at 240 V AC, three-phase 7.5 HP at 480 V AC, three-phase 7.5 HP at 600 V AC, three-phase
Mechanical & Physical
Product Length/Depth86 mm
Product Height48 mm
Product Width48 mm
Product Weight0.108 kg
Actuator colorBlack
10.3 Degree of protection of assembliesDoes not apply, since the entire switchgear needs to be evaluated.
10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.
10.8 Connections for external conductorsIs the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility.
Fitted with:Black thumb grip and front plate
Mounting positionAs required
Number of auxiliary contacts (change-over contacts)0
Number of auxiliary contacts (normally closed contacts)0
Degree of protection (front side)IP65
Number of poles4
Mounting methodFlush mounting
Degree of protectionNEMA 12
Screw sizeM3.5, Terminal screw
Terminal capacity18 - 14 AWG, solid or flexible with ferrule 2 x (1 - 2.5) mm², solid or stranded 1 x (1 - 2.5) mm², solid or stranded 2 x (0.75 - 2.5) mm², flexible with ferrules to DIN 46228 1 x (0.75 - 2.5) mm², flexible with ferrules to DIN 46228
Number of auxiliary contacts (normally open contacts)0
Number of contacts in series at DC-21A, 240 V1
Number of contacts in series at DC-23A, 120 V3
Number of contacts in series at DC-23A, 24 V1
Number of contacts in series at DC-23A, 240 V5
Number of contacts in series at DC-23A, 48 V2
Number of contacts in series at DC-23A, 60 V3
Tightening torque8.8 lb-in, Screw terminals 1 Nm, Screw terminals
Housing colorBlack
Housing materialPlastic
Environmental & Compliance
CertificationsCE CSA-C22.2 No. 94 IEC/EN 60204 UL VDE 0660 UL File No.: E36332 IEC/EN 60947 CSA CSA Class No.: 3211-05 UL Category Control No.: NLRV CSA File No.: 012528 CSA-C22.2 No. 60947-4-1-14 IEC/EN 60947-3 UL 60947-4-1
10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Pollution degree3
Climatic proofingDamp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30
Ambient operating temperature - max50 °C
Ambient operating temperature - min-25 °C
Ambient operating temperature (enclosed) - max40 °C
Ambient operating temperature (enclosed) - min-25 °C
Additional Specifications
Catalog NotesRated Short-time Withstand Current (Icw) for a time of 1 second
Actuator functionMaintained
10.12 Electromagnetic compatibilityIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.3.1 Verification of thermal stability of enclosuresMeets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements.
10.2.5 LiftingDoes not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated.
10.2.7 InscriptionsMeets the product standard's requirements.
10.4 Clearances and creepage distancesMeets the product standard's requirements.
10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.
Switching angle90 °
Device constructionBuilt-in device fixed built-in technique
Design8900
Control circuit reliability1 failure per 100,000 switching operations statistically determined, at 24 V DC, 10 mA)
Suitable forFront mounting 4-hole Branch circuits, suitable as motor disconnect, (UL/CSA)
Number of switches1
Inscription0-1
Load rating2 x Iₑ (with intermittent operation class 12, 25 % duty factor) 1.6 x Iₑ (with intermittent operation class 12, 40 % duty factor) 1.3 x Iₑ (with intermittent operation class 12, 60 % duty factor)
Safety parameter (EN ISO 13849-1)B10d values as per EN ISO 13849-1, table C.1
Number of contact units2

Note: Specifications are taken from the official Eaton T0-2-8900/E datasheet.

Documents & Downloads

Official technical documentation for the T0-2-8900/E.

Typical Applications

Typical applications of the T0-2-8900/E.

Machine Control
Panel Isolation
Position Sensing
Changeover Switching
Safety Circuits
12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment