Your Trusted Source for Industrial Electrical Components

T0-6-8282/IVS

Step switch

Eaton | Switches & Cam Switches | 069701

11.5 AAmperage
100 ABreaking Capacity
5.5 kWRated Power
Step switchProduct Type

Additional Technical Details

View Full Specifications
Product Weight0.229 kg
Product Length/Depth130 mm
Product Height55 mm
Product Width54 mm
Degree Of ProtectionIP30
Number Of PolesThree-pole

Standards & Approvals

  • Eaton global quality standards

Typical Applications

Machine Control, Panel Isolation, Position Sensing and more.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Technical Specifications

General Information
Product NameEaton Moeller® series T0 Step switch
Catalog Number069701
Model CodeT0-6-8282/IVS
EAN4015080697015
Global Catalog069701
Product TypeStep switch
TypeStep switch
Product categoryControl switches
Switch typeLevel switch
Actuator typeToggle
Electrical Characteristics
10.11 Short-circuit ratingIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.2.2 Corrosion resistanceMeets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiationMeets the product standard's requirements.
10.9.2 Power-frequency electric strengthIs the panel builder's responsibility.
10.9.3 Impulse withstand voltageIs the panel builder's responsibility.
Operating frequency1200 Operations/h
Rated impulse withstand voltage (Uimp)6000 V AC
Rated uninterrupted current (Iu)20 A
Static heat dissipation, non-current-dependent Pvs0 W
Voltage per contact pair in series60 V
Rated operational power at AC-3, 500 V, 50 Hz5.5 kW
Rated short-time withstand current (Icw)320 A, Contacts, 1 second
Assigned motor power at 115/120 V, 60 Hz, 1-phase0.5 HP
Assigned motor power at 200/208 V, 60 Hz, 1-phase1 HP
Assigned motor power at 200/208 V, 60 Hz, 3-phase3 HP
Assigned motor power at 230/240 V, 60 Hz, 1-phase1.5 HP
Assigned motor power at 230/240 V, 60 Hz, 3-phase3 HP
Assigned motor power at 460/480 V, 60 Hz, 3-phase7.5 HP
Assigned motor power at 575/600 V, 60 Hz, 3-phase7.5 HP
Equipment heat dissipation, current-dependent Pvid0 W
Rated conditional short-circuit current (Iq)6 kA
Overvoltage categoryIII
Heat dissipation capacity Pdiss0 W
Heat dissipation per pole, current-dependent Pvid0.6 W
Safe isolation440 V AC, Between the contacts, According to EN 61140
Shock resistance15 g, Mechanical, According to IEC/EN 60068-2-27, Half-sinusoidal shock 20 ms
Lifespan, mechanical400,000 Operations
Switching capacity (auxiliary contacts, general use)10A, IU, (UL/CSA)
Switching capacity (auxiliary contacts, pilot duty)P300 (UL/CSA) A600 (UL/CSA)
Rated breaking capacity at 220/230 V (cos phi to IEC 60947-3)100 A
Rated breaking capacity at 400/415 V (cos phi to IEC 60947-3)110 A
Rated breaking capacity at 500 V (cos phi to IEC 60947-3)80 A
Rated breaking capacity at 660/690 V (cos phi to IEC 60947-3)60 A
Rated making capacity up to 690 V (cos phi to IEC/EN 60947-3)130 A
Rated operating voltage (Ue) at AC - max690 V
Rated operational current (Ie) at AC-21, 440 V20 A
Rated operational current (Ie) at AC-23A, 230 V13.3 A
Rated operational current (Ie) at AC-23A, 400 V, 415 V13.3 A
Rated operational current (Ie) at AC-23A, 500 V13.3 A
Rated operational current (Ie) at AC-23A, 690 V7.6 A
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V11.5 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V11.5 A
Rated operational current (Ie) at AC-3, 500 V9 A
Rated operational current (Ie) at AC-3, 660 V, 690 V4.9 A
Rated operational current (Ie) at DC-1, load-break switches l/r = 1 ms10 A
Rated operational current (Ie) at DC-13, control switches L/R = 50 ms10 A
Rated operational current (Ie) at DC-21, 240 V1 A
Switching capacity (main contacts, general use)16 A, Rated uninterrupted current max. (UL/CSA)
Rated operational current (Ie) at DC-23A, 120 V5 A
Rated operational current (Ie) at DC-23A, 24 V10 A
Rated operational current (Ie) at DC-23A, 240 V5 A
Rated operational current (Ie) at DC-23A, 48 V10 A
Rated operational current (Ie) at DC-23A, 60 V10 A
Rated operational current (Ie) star-delta at AC-3, 230 V20 A
Rated operational current (Ie) star-delta at AC-3, 400 V20 A
Rated operational current (Ie) star-delta at AC-3, 500 V15.6 A
Rated operational current (Ie) star-delta at AC-3, 690 V8.5 A
Rated operational current for specified heat dissipation (In)20 A
Rated operational power at AC-23A, 220/230 V, 50 Hz3 kW
Rated operational power at AC-23A, 400 V, 50 Hz5.5 kW
Rated operational power at AC-23A, 500 V, 50 Hz7.5 kW
Rated operational power at AC-23A, 690 V, 50 Hz5.5 kW
Rated operational power at AC-3, 415 V, 50 Hz5.5 kW
Rated operational power at AC-3, 690 V, 50 Hz4 kW
Rated operational power star-delta at 220/230 V, 50 Hz5.5 kW
Rated operational power star-delta at 380/400 V, 50 Hz7.5 kW
Rated operational power star-delta at 500 V, 50 Hz7.5 kW
Rated operational power star-delta at 690 V, 50 Hz5.5 kW
Short-circuit current rating (basic rating)5 kA, SCCR (UL/CSA) 50A, max. Fuse, SCCR (UL/CSA)
Short-circuit current rating (high fault)10 kA, SCCR (UL/CSA) 20 A, Class J, max. Fuse, SCCR (UL/CSA)
Short-circuit protection rating20 A gG/gL, Fuse, Contacts
Uninterrupted currentRated uninterrupted current Iu is specified for max. cross-section.
Mechanical & Physical
Product Length/Depth130 mm
Product Height55 mm
Product Width54 mm
Product Weight0.229 kg
10.3 Degree of protection of assembliesDoes not apply, since the entire switchgear needs to be evaluated.
10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.
10.8 Connections for external conductorsIs the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility.
Fitted with:0 (off) position Black thumb grip and front plate
Width in number of modular spacings4
Number of polesThree-pole
Mounting positionAs required
Mounting methodService distribution board mounting
Degree of protectionIP30
Degree of protection (front side)IP30 NEMA 2
Number of contacts12
Number of contacts in series at DC-21A, 240 V1
Number of contacts in series at DC-23A, 120 V3
Number of contacts in series at DC-23A, 24 V1
Number of contacts in series at DC-23A, 240 V5
Front shield size48x48 mm
Screw sizeM3.5, Terminal screw
Number of contacts in series at DC-23A, 48 V2
Number of contacts in series at DC-23A, 60 V3
Terminal capacity (flexible with ferrule)1 x (0.75 - 2.5) mm², ferrules to DIN 46228 2 x (0.75 - 2.5) mm², ferrules to DIN 46228
Terminal capacity (solid/flexible with ferrule AWG)18 - 14
Terminal capacity (solid/stranded)2 x (1 - 2.5) mm² 1 x (1 - 2.5) mm²
Tightening torque8.8 lb-in, Screw terminals 1 Nm, Screw terminals
Environmental & Compliance
CertificationsCSA Class No.: 3211-05 CSA-C22.2 No. 60947-4-1-14 CSA-C22.2 No. 94 UL VDE 0660 UL Category Control No.: NLRV IEC/EN 60947-3 CE CSA CSA File No.: 012528 IEC/EN 60204 UL 60947-4-1 UL File No.: E36332 IEC/EN 60947
10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Pollution degree3
Climatic proofingDamp heat, cyclic, to IEC 60068-2-30 Damp heat, constant, to IEC 60068-2-78
Ambient operating temperature - max50 °C
Ambient operating temperature - min-25 °C
Ambient operating temperature (enclosed) - max40 °C
Ambient operating temperature (enclosed) - min-25 °C
Additional Specifications
Catalog NotesRated Short-time Withstand Current (Icw) for a time of 1 second
Actuator functionMaintained With 0 (Off) position
10.12 Electromagnetic compatibilityIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.3.1 Verification of thermal stability of enclosuresMeets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements.
10.2.5 LiftingDoes not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated.
10.2.7 InscriptionsMeets the product standard's requirements.
10.4 Clearances and creepage distancesMeets the product standard's requirements.
10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.
Switching angle45 °
Device constructionBuilt-in device
Control circuit reliability1 failure per 100,000 switching operations statistically determined, at 24 V DC, 10 mA)
Suitable forDistribution board installation Ground mounting Branch circuits, suitable as motor disconnect, (UL/CSA) Front mounting
Number of contact units6
Inscription0-4
Number of steps4 (45°)
Number of switch positions5
Load rating1.3 x Iₑ (with intermittent operation class 12, 60 % duty factor) 2 x Iₑ (with intermittent operation class 12, 25 % duty factor) 1.6 x Iₑ (with intermittent operation class 12, 40 % duty factor)
Safety parameter (EN ISO 13849-1)B10d values as per EN ISO 13849-1, table C.1
Design8282

Note: Specifications are taken from the official Eaton T0-6-8282/IVS datasheet.

Documents & Downloads

Official technical documentation for the T0-6-8282/IVS.

Typical Applications

Typical applications of the T0-6-8282/IVS.

Machine Control
Panel Isolation
Position Sensing
Changeover Switching
Safety Circuits
12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment