Your Trusted Source for Industrial Electrical Components

T3-1-8200/E-RT

T3 On-off switch

Eaton | T Rotary Cam switches and P Switch-disconnectors | T3-1-8200/E-RT

T3 On-off switchProduct Type

Additional Technical Details

View Full Specifications
Product Weight0.11 kg
Product Length/Depth79 mm
Product Height54 mm
Product Width61 mm

Standards & Approvals

  • CSA-C22.2 No. 94
  • IEC/EN 60947
  • IEC/EN 60947-3
  • UL 60947-4-1
  • UL
  • VDE 0660

Typical Applications

Manual switching, isolation and operator control of industrial machinery and switchgear.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Technical Specifications

General Information
Product NameEaton Moeller® series T3 On-off switch
Catalog Number017025
Model CodeT3-1-8200/E-RT
EAN4015080170259
Product Length/Depth79 mm
Product Height54 mm
Product Width61 mm
Product Weight0.11 kg
CertificationsCSA-C22.2 No. 94
IEC/EN 60947
IEC/EN 60947-3
UL 60947-4-1
UL
UL File No.: E36332
VDE 0660
CSA Class No.: 3211-07
UL Category Control No.: NLRV
CSA
CE
CSA File No.: 012528
CSA-C22.2 No. 60947-4-1-14
IEC/EN 60204
Catalog NotesRated Short-time Withstand Current (Icw) for a time of 1 second
Degree of protectionNEMA 12
Degree of protection (front side)IP65
Lifespan, mechanical500,000 Operations
Mounting methodFlush mounting
Mounting positionAs required
Number of contact units1
Operating frequency1200 Operations/h
Overvoltage categoryIII
Pollution degree3
Product CategoryOn-Off switch
Rated impulse withstand voltage (Uimp)6000 V AC
Safe isolation440 V AC, Between the contacts, According to EN 61140
Safety parameter (EN ISO 13849-1)B10d values as per EN ISO 13849-1, table C.1
Shock resistance15 g, Mechanical, According to IEC/EN 60068-2-27, Half-sinusoidal shock 20 ms
Suitable forFront mounting 4-hole
Branch circuits, suitable as motor disconnect, (UL/CSA)
Switching angle90 °
Electrical Characteristics
Rated breaking capacity at 220/230 V (cos phi to IEC 60947-3)260 A
Rated breaking capacity at 400/415 V (cos phi to IEC 60947-3)260 A
Rated breaking capacity at 500 V (cos phi to IEC 60947-3)240 A
Rated breaking capacity at 660/690 V (cos phi to IEC 60947-3)170 A
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V23.7 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V23.7 A
Rated operational current (Ie) at AC-3, 500 V23.7 A
Rated operational current (Ie) at AC-3, 660 V, 690 V14.7 A
Rated operational current (Ie) at AC-21, 440 V32 A
Rated operational current (Ie) at AC-23A, 400 V, 415 V32 A
Rated operational current (Ie) at AC-23A, 500 V26.4 A
Rated operational current (Ie) at AC-23A, 690 V17 A
Rated operational current (Ie) at DC-1, load-break switches l/r = 1 ms25 A
Rated operational current (Ie) at DC-13, control switches L/R = 50 ms20 A
Rated operational current (Ie) at DC-21, 240 V1 A
Rated operational current (Ie) at DC-23A, 24 V25 A
Rated operational current (Ie) at DC-23A, 48 V25 A
Rated operational current (Ie) at DC-23A, 60 V25 A
Rated operational current (Ie) at DC-23A, 120 V12 A
Rated operational current (Ie) at DC-23A, 240 V5 A
Rated operational current (Ie) star-delta at AC-3, 220/230 V32 A
Rated operational current (Ie) star-delta at AC-3, 380/400 V32 A
Rated operational current (Ie) star-delta at AC-3, 500 V32 A
Rated operational current (Ie) star-delta at AC-3, 690 V25.5 A
Rated operational power at AC-3, 380/400 V, 50 Hz11 kW
Rated operational power at AC-3, 415 V, 50 Hz11 kW
Rated operational power at AC-3, 500 V, 50 Hz15 kW
Rated operational power at AC-3, 690 V, 50 Hz11 kW
Rated operational power at AC-23A, 220/230 V, 50 Hz7.5 kW
Rated operational power at AC-23A, 400 V, 50 Hz15 kW
Rated operational power at AC-23A, 500 V, 50 Hz15 kW
Rated operational power at AC-23A, 690 V, 50 Hz15 kW
Rated operational power star-delta at 220/230 V, 50 Hz7.5 kW
Rated operational power star-delta at 380/400 V, 50 Hz15 kW
Rated operational power star-delta at 500 V, 50 Hz18.5 kW
Rated operational power star-delta at 690 V, 50 Hz22 kW
Rated operational voltage (Ue) at AC - max690 V
Rated uninterrupted current (Iu)32 A
Uninterrupted currentRated uninterrupted current Iu is specified for max. cross-section.
Switching capacity
Load rating1.3 x Iₑ (with intermittent operation class 12, 60 % duty factor)
2 x Iₑ (with intermittent operation class 12, 25 % duty factor)
1.6 x Iₑ (with intermittent operation class 12, 40 % duty factor)
Number of contacts in series at DC-21A, 240 V1
Number of contacts in series at DC-23A, 24 V1
Number of contacts in series at DC-23A, 48 V2
Number of contacts in series at DC-23A, 60 V3
Number of contacts in series at DC-23A, 120 V3
Number of contacts in series at DC-23A, 240 V5
Switching capacity (main contacts, general use)25 A, Rated uninterrupted current max. (UL/CSA)
Switching capacity (main contacts, general use)25 A, Rated uninterrupted current max. (UL/CSA)
Switching capacity (auxiliary contacts, pilot duty)A600 (UL/CSA)
P600 (UL/CSA)
Rated making capacity up to 690 V (cos phi to IEC/EN 60947-3)320 A
Voltage per contact pair in series60 V
Motor Rating & Protection
Assigned motor power at 115/120 V, 60 Hz, 1-phase1.5 HP
Assigned motor power at 200/208 V, 60 Hz, 1-phase3 HP
Assigned motor power at 200/208 V, 60 Hz, 3-phase3 HP
Assigned motor power at 230/240 V, 60 Hz, 1-phase3 HP
Assigned motor power at 230/240 V, 60 Hz, 3-phase3 HP
Assigned motor power at 460/480 V, 60 Hz, 3-phase7.5 HP
Assigned motor power at 575/600 V, 60 Hz, 3-phase10 HP
Standards & Design Verification
Heat dissipation capacity Pdiss0 W
Heat dissipation per pole, current-dependent Pvid1.1 W
Rated operational current for specified heat dissipation (In)32 A
Static heat dissipation, non-current-dependent Pvs0 W
10.2.2 Corrosion resistanceMeets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosuresMeets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiationUV resistance only in connection with protective shield.
10.2.5 LiftingDoes not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated.
10.2.7 InscriptionsMeets the product standard's requirements.
10.3 Degree of protection of assembliesDoes not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distancesMeets the product standard's requirements.
10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.
10.8 Connections for external conductorsIs the panel builder's responsibility.
10.9.2 Power-frequency electric strengthIs the panel builder's responsibility.
10.9.3 Impulse withstand voltageIs the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility.
10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit ratingIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibilityIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Additional Specifications
Screw sizeM4, Terminal screw
Tightening torque1.6 Nm, Screw terminals
17.7 lb-in, Screw terminals
Actuator colorRed
Actuator functionMaintained
Actuator typeShort thumb-grip
Rated conditional short-circuit current (Iq)1 kA
Short-circuit current rating (basic rating)40A, max. Fuse, SCCR (UL/CSA)
5 kA, SCCR (UL/CSA)
Short-circuit current rating (high fault)10 kA, SCCR (UL/CSA)
40 A, Class J, max. Fuse, SCCR (UL/CSA)
Short-circuit protection rating35 A gG/gL, Fuse, Contacts
Control circuit reliability1 failure per 100,000 switching operations statistically determined, at 24 V DC, 10 mA)
Number of auxiliary contacts (change-over contacts)0
Number of auxiliary contacts (normally closed contacts)0
Number of auxiliary contacts (normally open contacts)0
FeaturesVersion as emergency stop installation
Fitted with:Red thumb grip and yellow front plate
FunctionsEmergency switching off function
Inscription0-1
Number of poles1
Ambient operating temperature - min-25 °C
Ambient operating temperature - max50 °C
Ambient operating temperature (enclosed) - min-25 °C
Ambient operating temperature (enclosed) - max40 °C
Climatic proofingDamp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-78

Note: Specifications are taken from the official Eaton T3-1-8200/E-RT product data sheet.

Documents & Downloads

Official technical documentation for the T3-1-8200/E-RT.

Typical Applications

Typical applications of the T3-1-8200/E-RT.

Machine Control
Panel Isolation
Position Sensing
Changeover Switching
Safety Circuits
12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment