Your Trusted Source for Industrial Electrical Components

T3-2-8324/EA/SVB

Main switch

Eaton | Switches & Cam Switches | 008771

23.7 AAmperage
690 VVoltage
260 ABreaking Capacity
11 kWRated Power
Main switchProduct Type

Additional Technical Details

View Full Specifications
Product Weight0.204 kg
Product Length/Depth116 mm
Product Height74 mm
Product Width65 mm
Degree Of ProtectionNEMA 12
Number Of Poles4

Standards & Approvals

  • Eaton global quality standards

Typical Applications

Machine Control, Panel Isolation, Position Sensing and more.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Technical Specifications

General Information
Product NameEaton Moeller® series T3 Main switch
Catalog Number008771
Model CodeT3-2-8324/EA/SVB
EAN4015080087717
Global Catalog008771
Product TypeMain switch
Product CategoryMain switch
Electrical connection type of main circuitScrew connection
Actuator typeDoor coupling rotary drive
Electrical Characteristics
10.11 Short-circuit ratingIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.2.2 Corrosion resistanceMeets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiationUV resistance only in connection with protective shield.
10.9.2 Power-frequency electric strengthIs the panel builder's responsibility.
10.9.3 Impulse withstand voltageIs the panel builder's responsibility.
Operating frequency1200 Operations/h
Rated impulse withstand voltage (Uimp)6000 V AC
Rated operational power star-delta at 500 V, 50 Hz18.5 kW
Rated operational power star-delta at 690 V, 50 Hz22 kW
Rated permanent current at AC-21, 400 V32 A
Rated uninterrupted current (Iu)32 A
Static heat dissipation, non-current-dependent Pvs0 W
Switching power at 400 V15 kW
Voltage per contact pair in series60 V
Rated operational power at AC-3, 500 V, 50 Hz15 kW
Rated short-time withstand current (Icw)0.65 kA 650 A, Contacts, 1 second
Assigned motor power at 115/120 V, 60 Hz, 1-phase1.5 HP
Assigned motor power at 200/208 V, 60 Hz, 1-phase3 HP
Assigned motor power at 200/208 V, 60 Hz, 3-phase3 HP
Assigned motor power at 230/240 V, 60 Hz, 1-phase3 HP
Assigned motor power at 230/240 V, 60 Hz, 3-phase3 HP
Assigned motor power at 460/480 V, 60 Hz, 3-phase7.5 HP
Assigned motor power at 575/600 V, 60 Hz, 3-phase10 HP
Equipment heat dissipation, current-dependent Pvid0 W
Heat dissipation capacity Pdiss0 W
Heat dissipation per pole, current-dependent Pvid1.1 W
Rated conditional short-circuit current (Iq)1 kA
Overvoltage categoryIII
Safe isolation440 V AC, Between the contacts, According to EN 61140
Shock resistance15 g, Mechanical, According to IEC/EN 60068-2-27, Half-sinusoidal shock 20 ms
Lifespan, mechanical500,000 Operations
Switching capacity (auxiliary contacts, general use)10A, IU, (UL/CSA)
Switching capacity (auxiliary contacts, pilot duty)P600 (UL/CSA) A600 (UL/CSA)
Switching capacity (main contacts, general use)25 A, Rated uninterrupted current max. (UL/CSA)
Rated breaking capacity at 220/230 V (cos phi to IEC 60947-3)260 A
Rated breaking capacity at 400/415 V (cos phi to IEC 60947-3)260 A
Rated breaking capacity at 500 V (cos phi to IEC 60947-3)240 A
Rated breaking capacity at 660/690 V (cos phi to IEC 60947-3)170 A
Rated making capacity up to 690 V (cos phi to IEC/EN 60947-3)320 A
Rated operating voltage (Ue) - max690 V
Rated operating voltage (Ue) - min690 V
Rated operational voltage (Ue) at AC - max690 V
Short-circuit current rating (basic rating)40A, max. Fuse, SCCR (UL/CSA) 5 kA, SCCR (UL/CSA)
Short-circuit current rating (high fault)10 kA, SCCR (UL/CSA) 40 A, Class J, max. Fuse, SCCR (UL/CSA)
Short-circuit protection rating35 A gG/gL, Fuse, Contacts
Rated operational current (Ie) at AC-21, 440 V32 A
Rated operational current (Ie) at AC-23A, 230 V32 A
Rated operational current (Ie) at AC-23A, 400 V, 415 V32 A
Rated operational current (Ie) at AC-23A, 500 V26.4 A
Rated operational current (Ie) at AC-23A, 690 V17 A
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V23.7 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V23.7 A
Rated operational current (Ie) at AC-3, 500 V23.7 A
Rated operational current (Ie) at AC-3, 660 V, 690 V14.7 A
Rated operational current (Ie) at DC-1, load-break switches l/r = 1 ms25 A
Rated operational current (Ie) at DC-13, control switches L/R = 50 ms20 A
Rated operational current (Ie) at DC-21, 240 V1 A
Rated operational current (Ie) at DC-23A, 120 V12 A
Rated operational current (Ie) at DC-23A, 24 V25 A
Rated operational current (Ie) at DC-23A, 240 V5 A
Rated operational current (Ie) at DC-23A, 48 V25 A
Rated operational current (Ie) at DC-23A, 60 V25 A
Rated operational current (Ie) star-delta at AC-3, 220/230 V32 A
Rated operational current (Ie) star-delta at AC-3, 380/400 V32 A
Rated operational current (Ie) star-delta at AC-3, 500 V32 A
Rated operational current (Ie) star-delta at AC-3, 690 V25.5 A
Rated operational current for specified heat dissipation (In)32 A
Rated operational power at AC-23A, 220/230 V, 50 Hz7.5 kW
Rated operational power at AC-23A, 400 V, 50 Hz15 kW
Rated operational power at AC-23A, 500 V, 50 Hz15 kW
Rated operational power at AC-23A, 690 V, 50 Hz15 kW
Rated operational power at AC-3, 380/400 V, 50 Hz11 kW
Rated operational power at AC-3, 415 V, 50 Hz11 kW
Rated operational power at AC-3, 690 V, 50 Hz11 kW
Rated operational power star-delta at 220/230 V, 50 Hz7.5 kW
Rated operational power star-delta at 380/400 V, 50 Hz15 kW
Uninterrupted currentRated uninterrupted current Iu is specified for max. cross-section.
Mechanical & Physical
Product Length/Depth116 mm
Product Height74 mm
Product Width65 mm
Product Weight0.204 kg
Actuator colorRed
10.3 Degree of protection of assembliesDoes not apply, since the entire switchgear needs to be evaluated.
10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.
10.8 Connections for external conductorsIs the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility.
Fitted with:Red rotary handle and yellow locking ring
Mounting positionAs required
Number of auxiliary contacts (change-over contacts)0
Number of auxiliary contacts (normally closed contacts)0
Degree of protection (front side)IP65
Number of poles4
Mounting methodFlush mounting
Degree of protectionNEMA 12
Screw sizeM4, Terminal screw
Terminal capacity14 - 10 AWG, solid or flexible with ferrule 1 x (0.75 - 4) mm², flexible with ferrules to DIN 46228 2 x (0.75 - 4) mm², flexible with ferrules to DIN 46228 1 x (1 - 6) mm², solid or stranded 2 x (1 - 6) mm², solid or stranded
Number of auxiliary contacts (normally open contacts)0
Number of contacts in series at DC-21A, 240 V1
Number of contacts in series at DC-23A, 120 V3
Number of contacts in series at DC-23A, 24 V1
Number of contacts in series at DC-23A, 240 V5
Number of contacts in series at DC-23A, 48 V2
Number of contacts in series at DC-23A, 60 V3
Tightening torque1.6 Nm, Screw terminals 17.7 lb-in, Screw terminals
Housing materialPlastic
Environmental & Compliance
CertificationsUL Category Control No.: NLRV VDE 0660 CSA CSA File No.: 012528 UL 60947-4-1 IEC/EN 60947-3 CE CSA-C22.2 No. 60947-4-1-14 IEC/EN 60204 IEC/EN 60947 UL File No.: E36332 UL CSA Class No.: 3211-05 CSA-C22.2 No. 94
10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Pollution degree3
Climatic proofingDamp heat, cyclic, to IEC 60068-2-30 Damp heat, constant, to IEC 60068-2-78
Ambient operating temperature - max50 °C
Ambient operating temperature - min-25 °C
Ambient operating temperature (enclosed) - max40 °C
Ambient operating temperature (enclosed) - min-25 °C
Additional Specifications
Catalog NotesRated Short-time Withstand Current (Icw) for a time of 1 second
FeaturesVersion as emergency stop installation Version as main switch Version as maintenance-/service switch
10.12 Electromagnetic compatibilityIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.3.1 Verification of thermal stability of enclosuresMeets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements.
10.2.5 LiftingDoes not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated.
10.2.7 InscriptionsMeets the product standard's requirements.
10.4 Clearances and creepage distancesMeets the product standard's requirements.
10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.
Switching angle90 °
Device constructionBuilt-in device fixed built-in technique
Design8324
Control circuit reliability1 failure per 100,000 switching operations statistically determined, at 24 V DC, 10 mA)
Suitable forFront mounting center Branch circuits, suitable as motor disconnect, (UL/CSA)
FunctionsEmergency switching off function Interlockable
Number of switches1
Load rating2 x Iₑ (with intermittent operation class 12, 25 % duty factor) 1.6 x Iₑ (with intermittent operation class 12, 40 % duty factor) 1.3 x Iₑ (with intermittent operation class 12, 60 % duty factor)
Safety parameter (EN ISO 13849-1)B10d values as per EN ISO 13849-1, table C.1
Number of contact units2

Note: Specifications are taken from the official Eaton T3-2-8324/EA/SVB datasheet.

Documents & Downloads

Official technical documentation for the T3-2-8324/EA/SVB.

Typical Applications

Typical applications of the T3-2-8324/EA/SVB.

Machine Control
Panel Isolation
Position Sensing
Changeover Switching
Safety Circuits
12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment