Your Trusted Source for Industrial Electrical Components

T5-4-8223/I5

Changeover switch

Eaton | Switches & Cam Switches | 207271

71 AAmperage
690 VVoltage
760 ABreaking Capacity
30 kWRated Power
Changeover switchProduct Type

Additional Technical Details

View Full Specifications
Product Weight2.238 kg
Product Length/Depth280 mm
Product Height197 mm
Product Width200 mm
Degree Of ProtectionIP65
Number Of Poles4

Standards & Approvals

  • Eaton global quality standards

Typical Applications

Machine Control, Panel Isolation, Position Sensing and more.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Technical Specifications

General Information
Product NameEaton Moeller® series T5 Changeover switch
Catalog Number207271
Model CodeT5-4-8223/I5
EAN4015082072711
Global Catalog207271
Product TypeChangeover switch
TypeChangeover switch
Product CategoryControl switches
Actuator typeShort thumb-grip
Electrical connection type of main circuitScrew connection
Electrical Characteristics
10.11 Short-circuit ratingIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.2.2 Corrosion resistanceMeets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiationUV resistance only in connection with protective shield.
10.9.2 Power-frequency electric strengthIs the panel builder's responsibility.
10.9.3 Impulse withstand voltageIs the panel builder's responsibility.
Operating frequency1200 Operations/h
Rated impulse withstand voltage (Uimp)6000 V AC
Equipment heat dissipation, current-dependent Pvid0 W
Heat dissipation capacity Pdiss0 W
Heat dissipation per pole, current-dependent Pvid7.5 W
Rated short-time withstand current (Icw)1,7 kA, Contacts, 1 second
Rated conditional short-circuit current (Iq)2 kA
Overvoltage categoryIII
Lifespan, mechanical500,000 Operations
Safe isolation440 V AC, Between the contacts, According to EN 61140
Rated operational current (Ie)29.4 A at AC-3, 690 V star-delta 95.3 A at AC-3, 400 V star-delta 76.2 A at AC-3, 500 V star-delta 100 A at AC-3, 230 V star-delta
Shock resistance15 g, Mechanical, According to IEC/EN 60068-2-27, Half-sinusoidal shock 20 ms
Rated breaking capacity at 220/230 V (cos phi to IEC 60947-3)760 A
Rated breaking capacity at 400/415 V (cos phi to IEC 60947-3)740 A
Rated breaking capacity at 500 V (cos phi to IEC 60947-3)590 A
Rated breaking capacity at 660/690 V (cos phi to IEC 60947-3)420 A
Rated making capacity up to 690 V (cos phi to IEC/EN 60947-3)950 A
Rated operational current (Ie) at AC-21, 440 V100 A
Rated operational current (Ie) at AC-23A, 230 V100 A
Rated operational current (Ie) at AC-23A, 400 V, 415 V100 A
Rated operational current (Ie) at AC-23A, 500 V55 A
Rated operational current (Ie) at AC-23A, 690 V32 A
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V71 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V55 A
Rated operational current (Ie) at AC-3, 500 V44 A
Rated operational current (Ie) at AC-3, 660 V, 690 V17 A
Short-circuit protection rating100 A gG/gL, Fuse, Contacts
Rated operational current (Ie) at DC-1, load-break switches l/r = 1 ms80 A
Rated operational current for specified heat dissipation (In)100 A
Rated operational power at AC-23A, 220/230 V, 50 Hz30 kW
Rated operational power at AC-23A, 400 V, 50 Hz55 kW
Rated operational power at AC-23A, 500 V, 50 Hz37 kW
Rated operational power at AC-23A, 690 V, 50 Hz30 kW
Rated operational power at AC-3, 380/400 V, 50 Hz30 kW
Rated operational power at AC-3, 415 V, 50 Hz30 kW
Rated operational power at AC-3, 690 V, 50 Hz15 kW
Rated operational power star-delta at 220/230 V, 50 Hz30 kW
Rated operational power star-delta at 380/400 V, 50 Hz45 kW
Rated operational power star-delta at 500 V, 50 Hz45 kW
Rated operational power star-delta at 690 V, 50 Hz22 kW
Rated operational voltage (Ue) at AC - max690 V
Rated uninterrupted current (Iu)100 A
Static heat dissipation, non-current-dependent Pvs0 W
Voltage per contact pair in series60 V
Uninterrupted currentRated uninterrupted current Iu is specified for max. cross-section.
Mechanical & Physical
Product Length/Depth280 mm
Product Height197 mm
Product Width200 mm
Product Weight2.238 kg
10.3 Degree of protection of assembliesDoes not apply, since the entire switchgear needs to be evaluated.
10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.
10.8 Connections for external conductorsIs the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility.
Fitted with:Black thumb grip and front plate
Enclosure materialPlastic
Number of auxiliary contacts (change-over contacts)0
Number of auxiliary contacts (normally closed contacts)0
Number of auxiliary contacts (normally open contacts)0
Mounting positionAs required
Mounting methodSurface mounting
Number of poles4
Degree of protectionIP65
Number of contacts8
Degree of protection (front side)IP65 NEMA 12
Screw sizeM6, Terminal screw
Tightening torque4 Nm, Screw terminals
Terminal capacity (flexible with ferrule)2 x (1.5 - 10) mm², ferrule to DIN 46228 1 x (1 - 25) mm², ferrules to DIN 46228
Terminal capacity (solid/stranded)1 x (2.5 - 35) mm² 2 x (2.5 - 16) mm²
Environmental & Compliance
CertificationsVDE 0660 IEC/EN 60947 IEC/EN 60947-3 IEC/EN 60204
10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Pollution degree3
Climatic proofingDamp heat, cyclic, to IEC 60068-2-30 Damp heat, constant, to IEC 60068-2-78
Ambient operating temperature - max40 °C
Ambient operating temperature - min-25 °C
Ambient operating temperature (enclosed) - max40 °C
Ambient operating temperature (enclosed) - min-25 °C
Additional Specifications
Catalog NotesRated Short-time Withstand Current (Icw) for a time of 1 second
FeaturesComplete device in housing
Actuator functionMaintained Without 0 (Off) position
10.12 Electromagnetic compatibilityIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.3.1 Verification of thermal stability of enclosuresMeets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements.
10.2.5 LiftingDoes not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated.
10.2.7 InscriptionsMeets the product standard's requirements.
10.4 Clearances and creepage distancesMeets the product standard's requirements.
10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.
Number of contact units4
Control circuit reliability1 failure per 100,000 switching operations statistically determined, at 24 V DC, 10 mA)
ModelReverser
Inscription1-2
Load rating1.6 x Iₑ (with intermittent operation class 12, 40 % duty factor) 2 x Iₑ (with intermittent operation class 12, 25 % duty factor) 1.3 x Iₑ (with intermittent operation class 12, 60 % duty factor)
Safety parameter (EN ISO 13849-1)B10d values as per EN ISO 13849-1, table C.1
Suitable forGround mounting Front mounting
Switching angle90 °
Design8223

Note: Specifications are taken from the official Eaton T5-4-8223/I5 datasheet.

Documents & Downloads

Official technical documentation for the T5-4-8223/I5.

Typical Applications

Typical applications of the T5-4-8223/I5.

Machine Control
Panel Isolation
Position Sensing
Changeover Switching
Safety Circuits
12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment