Your Trusted Source for Industrial Electrical Components

AK 200 C420L

AC Current Transducer

LEM | AK-Series | Panel Mount

24 V DCPower Supply
20-100 HzBandwidth (-1dB)
120 gMass (m)
±1 mmGeneral Tolerance
+ 50 °CAmbient operating temperature (0-95 % RH) −20 … (T)

Additional Technical Details

View Full Specifications
Supply Voltage24 V DC
Operating Temperature Range(0-95 % RH) −20 …
Frequency Bandwidth (BW)20-100 Hz
Step response time to 90 % of I (t)< 300 ms
Ambient Operating Temperature (TA)(0-95 % RH) −20 …
Ambient Storage Temperature (TA st)−20 … + 85 °C

Standards & Approvals

Typical Applications

Automation systems Analog current reading for remote monitoring (e.g. motor), Data loggers Self-powered transducer does not drain data logger batteries, Panel meters Simple connection displays power consumption. Options on request, DIN mounting

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The AK 200 C420L is a None current transducer from LEM.

Since it cannot saturate, very high and short-circuit currents are measured without degradation. Typical applications include Automation systems Analog current reading for remote monitoring (e.g. motor), Data loggers Self-powered transducer does not drain data logger batteries, Panel meters Simple connection displays power consumption. Options on request and DIN mounting.

Key characteristics from the official datasheet: frequency bandwidth 20-100 Hz; operating temperature (0-95 % RH) −20 ….

Technical Specifications

General Information
ManufacturerLEM
Product SeriesAK
Product ReferenceAK 200 C420L
Supply Voltage24 V DC
Measurement—
MountingPanel Mount
Application DomainRenewable Energies and
Electrical Data — AK 200 C420L
Supply Voltage (UC)24 V DC
Supply voltage (U)24 V
Accuracy & Dynamic Performance
Frequency Bandwidth (BW)20-100 Hz
Step response time to 90 % of I (t)< 300 ms
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)(0-95 % RH) −20 …
Ambient Storage Temperature (TA st)−20 … + 85 °C
Mass (m)120 g
General Tolerance±1 mm
Ambient operating temperature (0-95 % RH) −20 … (T)+ 50 °C
Ambient storage temperature −20 … (T)+ 85 °C
Sandards Safety IEC 61010-1:2001
EMC EN 61326-1:2005
Insulation Coordination
Rms voltage for AC insulation test 1), 50 Hz (U)1 min 3 kV

Note: Specifications are taken from the official AK 200 C420L datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the AK 200 C420L are shown below.

AK 200 C420L outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM AK 200 C420L datasheet, page 3
Outline Dimensions & Mechanical Data
General Tolerance±1 mm
Mass120 g

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the AK 200 C420L.

Automation systems Analog current reading for remote monitoring (e.g. motor)
Data loggers Self-powered transducer does not drain data logger batteries
Panel meters Simple connection displays power consumption. Options on request
DIN mounting

Characteristic Curves

Characteristic curve diagrams are not included in the AK 200 C420L datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Accuracy & Dynamic Characteristics
Frequency Bandwidth (BW)20-100 Hz
Step response time to 90 % of I (t)< 300 ms

Note: For the full set of performance data, refer to the datasheet.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment