Your Trusted Source for Industrial Electrical Components

AK 5 B420L

AC Current transducer

LEM | AK-Series | Panel Mount

(Loop powered) 24 V DCPower Supply
-20..+85 °CAmbient Storage Temperature (TA st)
120 gMass (m)
61326EMC EN
< 300 mSResponse time @ 90% of I (t)

Additional Technical Details

View Full Specifications
Supply Voltage(Loop powered) 24 V DC
Operating Temperature Range(0-95% RH) -20
AK 5 B420L JULY (2,54-20)2006
Vc Supply voltage (Loop powered)24 V
RMS Isolation voltage test, 50 Hz (V)1mn 3 kV
Ambient Operating Temperature (TA)(0-95% RH) -20

Standards & Approvals

Typical Applications

UNVERIFIED

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Technical Specifications

General Information
ManufacturerLEM
Product SeriesAK
Product ReferenceAK 5 B420L
Supply Voltage(Loop powered) 24 V DC
Measurement—
MountingPanel Mount
Application Domain—
Electrical Data — AK 5 B420L
Supply Voltage (UC)(Loop powered) 24 V DC
AK 5 B420L JULY (2,54-20)2006
Vc Supply voltage (Loop powered)24 V
RMS Isolation voltage test, 50 Hz (V)1mn 3 kV
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)(0-95% RH) -20
Ambient Storage Temperature (TA st)-20..+85 °C
Mass (m)120 g
EMC EN61326
Accuracy & Dynamic Performance
Response time @ 90% of I (t)< 300 mS

Note: Specifications are taken from the official AK 5 B420L datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the AK 5 B420L are shown below.

AK 5 B420L outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM AK 5 B420L datasheet, page 2
Outline Dimensions & Mechanical Data
Mass120 g

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the AK 5 B420L.

UNVERIFIED

Characteristic Curves

Characteristic curve diagrams are not included in the AK 5 B420L datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Accuracy & Dynamic Characteristics
Response time @ 90% of I (t)< 300 mS

Note: For the full set of performance data, refer to the datasheet.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment