Your Trusted Source for Industrial Electrical Components

AK 50 B10

AC Current transducer

LEM | AK-Series | Panel Mount

Self PoweredPower Supply
-20..+85 °CAmbient Storage Temperature (TA st)
120 gMass (m)
61326EMC EN
< 100 mSResponse time @ 90% of I (t)

Additional Technical Details

View Full Specifications
Supply VoltageSelf Powered
Operating Temperature Range(0-95% RH) -20
Load resistance (R)1
Rated voltage(CAT III, PD2) (V)150 V
RMS Isolation voltage test, 50 Hz (V)1mn 3 kV
Ambient Operating Temperature (TA)(0-95% RH) -20

Standards & Approvals

Typical Applications

UNVERIFIED

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Technical Specifications

General Information
ManufacturerLEM
Product SeriesAK
Product ReferenceAK 50 B10
Supply VoltageSelf Powered
Measurement—
MountingPanel Mount
Application Domain—
Electrical Data — AK 50 B10
Supply Voltage (UC)Self Powered
Load resistance (R)1
Rated voltage(CAT III, PD2) (V)150 V
RMS Isolation voltage test, 50 Hz (V)1mn 3 kV
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)(0-95% RH) -20
Ambient Storage Temperature (TA st)-20..+85 °C
Mass (m)120 g
EMC EN61326
Accuracy & Dynamic Performance
Response time @ 90% of I (t)< 100 mS

Note: Specifications are taken from the official AK 50 B10 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the AK 50 B10 are shown below.

AK 50 B10 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM AK 50 B10 datasheet, page 2
Outline Dimensions & Mechanical Data
Mass120 g

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the AK 50 B10.

UNVERIFIED

Characteristic Curves

Characteristic curve diagrams are not included in the AK 50 B10 datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Accuracy & Dynamic Characteristics
Response time @ 90% of I (t)< 100 mS
Reference Conditions
Ambient Temperature (TA)25 °C, unless otherwise noted
Output Load Resistance (RL)1

Note: For the full set of performance data, refer to the datasheet.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment