Authorized Distributor
?
Open Loop transducer using the Hall effect
| Primary Current, Measuring Range | ± 75 A / ± 500 A |
| Supply Voltage | 4.75 .. 5.25 V |
| Sensitivity | 26.7 / 4 mV/A |
| Operating Temperature Range | −10 .. 65 °C / −40 .. 125 °C |
| Isolation Test Voltage | 2.5 kV |
| Primary Nominal Current (IPN) | ± 75 A / ± 500 A |
Dual channel sensor for wider measurement range and d thickness of the Hall plate redundancy. I current across Hall plates Hall.
The DHAB S/124 is an open loop current transducer from LEM for the electronic measurement of DC, AC, or pulsed currents, with galvanic isolation, delivering an instantaneous output voltage of 2.5 V.
Typical applications include Dual channel sensor for wider measurement range and d thickness of the Hall plate redundancy. I current across Hall plates Hall.
Key characteristics from the official datasheet: linearity error ± 0.5 %; frequency bandwidth 70 Hz; operating temperature −10 .. 65 °C / −40 .. 125 °C.
| General Information | |
|---|---|
| Manufacturer | LEM |
| Product Series | DHAB |
| Product Reference | DHAB S/124 |
| Primary Nominal Current | ± 75 A / ± 500 A |
| Supply Voltage | 4.75 .. 5.25 V |
| Measurement | DC, AC, or pulsed currents |
| Mounting | Busbar Mount |
| Application Domain | Dual channel sensor for wider measurement range and d thickness of the Hall plate redundancy |
| Electrical Data — DHAB S/124 | |
|---|---|
| Primary Nominal Current (IPN) | ± 75 A / ± 500 A |
| Primary Current, Measuring Range (IPM) | ± 75 A / ± 500 A |
| Supply Voltage (UC) | 4.75 .. 5.25 V |
| Current Consumption (IC) | 15 .. 20 mA |
| Sensitivity | 26.7 / 4 mV/A |
| Output Offset Voltage (VO E) | 2.5 V |
| Load Resistance (RL) | 10 kOhm |
| Insulation Resistance (RINS) | 500 MOhm |
| Accuracy & Dynamic Performance | |
|---|---|
| Ratiometricity Error | ± 0.6 % |
| Sensitivity Error | ± 1.0 % |
| Linearity Error | ± 0.5 % |
| Frequency Bandwidth | 70 Hz |
| Output Noise | ± 10 mV |
| Insulation Coordination | |
|---|---|
| RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud | 2.5 kV |
| Creepage Distance (dCp) | 3.1 mm |
| Clearance (dCI) | 3.1 mm |
| Comparative Tracking Index (CTI) | PLC3 |
| Environmental & Mechanical Characteristics | |
|---|---|
| Ambient Operating Temperature (TA) | −10 .. 65 °C / −40 .. 125 °C |
| Ambient Storage Temperature (TA st) | −40 .. 125 °C |
| Mass (m) | 82 g |
Note: Specifications are taken from the official DHAB S/124 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.
Official technical documentation for the DHAB S/124.
Outline dimensions, pin layout and connection diagrams of the DHAB S/124 are shown below.
| Outline Dimensions & Mechanical Data | |
|---|---|
| Mass | 82 g |
Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.
Typical applications of the DHAB S/124.
The characteristic curves of the DHAB S/124 from the official datasheet are shown below.
| Accuracy & Dynamic Characteristics | |
|---|---|
| Sensitivity | 26.7 / 4 mV/A |
| Sensitivity Error | ± 1.0 % |
| Linearity Error | ± 0.5 % |
| Frequency Bandwidth | 70 Hz |
| Reference Conditions | |
|---|---|
| Ambient Temperature (TA) | 25 °C, unless otherwise noted |
| Output Load Resistance (RL) | 10 kOhm |