Your Trusted Source for Industrial Electrical Components
Home Products LEM Automotive Series DHAB Series DHAB S/125

DHAB S/125

Open Loop transducer using the Hall effect

LEM | DHAB-Series | Open Loop Transducer | Busbar Mount

± 25 A / ± 200 ANominal Primary Current
4.75 .. 5.25 VPower Supply
Open Loop TransducerTechnology
70 HzBandwidth (-1dB)
± 0.5 %Linearity Error (Max)

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range± 25 A / ± 200 A
Supply Voltage4.75 .. 5.25 V
Sensitivity80 / 10 mV/A
Operating Temperature Range−10 .. 65 °C / −40 .. 125 °C
Isolation Test Voltage2.5 kV
Primary Nominal Current (IPN)± 25 A / ± 200 A

Standards & Approvals

Typical Applications

Dual channel transducer for wider measurement range and Hall redundancy. The measurement signal U is amplified to supply the user Hall output voltage or current.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The DHAB S/125 is an open loop current transducer from LEM for the electronic measurement of DC, AC, or pulsed currents, with galvanic isolation, delivering an instantaneous output voltage of 2.5 V.

Typical applications include Dual channel transducer for wider measurement range and Hall redundancy. The measurement signal U is amplified to supply the user Hall output voltage or current.

Key characteristics from the official datasheet: linearity error ± 0.5 %; frequency bandwidth 70 Hz; operating temperature −10 .. 65 °C / −40 .. 125 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesDHAB
Product ReferenceDHAB S/125
Primary Nominal Current± 25 A / ± 200 A
Supply Voltage4.75 .. 5.25 V
MeasurementDC, AC, or pulsed currents
MountingBusbar Mount
Application DomainDual channel transducer for wider measurement range and Hall redundancy
Electrical Data — DHAB S/125
Primary Nominal Current (IPN)± 25 A / ± 200 A
Primary Current, Measuring Range (IPM)± 25 A / ± 200 A
Supply Voltage (UC)4.75 .. 5.25 V
Current Consumption (IC)15 .. 20 mA
Sensitivity80 / 10 mV/A
Output Offset Voltage (VO E)2.5 V
Load Resistance (RL)10 kOhm
Insulation Resistance (RINS)500 MOhm
Accuracy & Dynamic Performance
Ratiometricity Error± 0.6 %
Sensitivity Error± 1.0 %
Linearity Error± 0.5 %
Frequency Bandwidth70 Hz
Output Noise± 10 mV
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud2.5 kV
Creepage Distance (dCp)3.1 mm
Clearance (dCI)3.1 mm
Comparative Tracking Index (CTI)PLC3
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−10 .. 65 °C / −40 .. 125 °C
Ambient Storage Temperature (TA st)−40 .. 125 °C
Mass (m)82 g

Note: Specifications are taken from the official DHAB S/125 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the DHAB S/125 are shown below.

DHAB S/125 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM DHAB S/125 datasheet
Outline Dimensions & Mechanical Data
Mass82 g

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the DHAB S/125.

Dual channel transducer for wider measurement range and Hall redundancy. The measurement signal U is amplified to supply the user Hall output voltage or current

Characteristic Curves

The characteristic curves of the DHAB S/125 from the official datasheet are shown below.

DHAB S/125 characteristic curves
Characteristic curves — source: LEM DHAB S/125 datasheet
Accuracy & Dynamic Characteristics
Sensitivity80 / 10 mV/A
Sensitivity Error± 1.0 %
Linearity Error± 0.5 %
Frequency Bandwidth70 Hz
Reference Conditions
Ambient Temperature (TA)25 °C, unless otherwise noted
Output Load Resistance (RL)10 kOhm