Your Trusted Source for Industrial Electrical Components
Home Products LEM Automotive Series DHAB Series DHAB S/134

DHAB S/134

Open Loop transducer using the Hall effect

LEM | DHAB-Series | Open Loop Transducer | Busbar Mount

± 50 A / ± 200 ANominal Primary Current
4.75 .. 5.25 VPower Supply
Open Loop TransducerTechnology
278 HzBandwidth (-1dB)
2.5 VOutput Offset Voltage (VO E)

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range± 50 A / ± 200 A
Supply Voltage4.75 .. 5.25 V
Sensitivity40 / 10 mV/A
Operating Temperature Range−10 .. 65 °C / −40 .. 125 °C
Primary Nominal Current (IPN)± 50 A / ± 200 A
Current Consumption (IC)15 .. 20 mA

Standards & Approvals

Typical Applications

Dual channel sensor for wider measurement range and redundancy.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Technical Specifications

General Information
ManufacturerLEM
Product SeriesDHAB
Product ReferenceDHAB S/134
Primary Nominal Current± 50 A / ± 200 A
Supply Voltage4.75 .. 5.25 V
MeasurementDC, AC, or pulsed currents
MountingBusbar Mount
Application DomainDual channel sensor for wider measurement range and redundancy
Electrical Data — DHAB S/134
Primary Nominal Current (IPN)± 50 A / ± 200 A
Primary Current, Measuring Range (IPM)± 50 A / ± 200 A
Supply Voltage (UC)4.75 .. 5.25 V
Current Consumption (IC)15 .. 20 mA
Sensitivity40 / 10 mV/A
Output Offset Voltage (VO E)2.5 V
Load Resistance (RL)10 kOhm
Insulation Resistance (RINS)500 MOhm
Accuracy & Dynamic Performance
Ratiometricity Error± 0.6 %
Frequency Bandwidth278 Hz
Output Noise± 10 mV
Insulation Coordination
Creepage Distance (dCp)3.1 mm
Clearance (dCI)3.1 mm
Comparative Tracking Index (CTI)PLC3
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−10 .. 65 °C / −40 .. 125 °C
Ambient Storage Temperature (TA st)−40 .. 125 °C
Mass (m)82 g

Note: Specifications are taken from the official DHAB S/134 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the DHAB S/134 are shown below.

DHAB S/134 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM DHAB S/134 datasheet
Outline Dimensions & Mechanical Data
Mass82 g

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the DHAB S/134.

Dual channel sensor for wider measurement range and redundancy

Characteristic Curves

The characteristic curves of the DHAB S/134 from the official datasheet are shown below.

DHAB S/134 characteristic curves
Characteristic curves — source: LEM DHAB S/134 datasheet
Accuracy & Dynamic Characteristics
Sensitivity40 / 10 mV/A
Frequency Bandwidth278 Hz
Reference Conditions
Ambient Temperature (TA)25 °C, unless otherwise noted
Output Load Resistance (RL)10 kOhm

Note: Refer to the datasheet for the complete set of characteristic curves.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment