Authorized Distributor
?
Voltage transducer
| Primary Voltage, Measuring Range | −1500 ... 1500 V |
| Secondary Nominal RMS Current | 50 mA |
| Sensitivity | 50 µA/V |
| Offset Current @ 25 °C | −50 ... 50 µA (100 % tested) |
| Isolation Test Voltage | 8.5 kV |
| Operating Temperature Range | −40 ... 85 °C |
AC variable speed and servo motor drives, Static converters for DC motor drives, Battery supplied applications, Uninterruptible Power Supplies (UPS), Switched Mode Power Supplies (SMPS), Power supplies for welding applications, Renewable Energy (Solar and Wind), Propulsion and braking choppers, Propulsion converters, Auxiliary converters, High power drives, Substations.
The DVL 1000/SP7 is a None current transducer from LEM for the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation.
It offers excellent accuracy. Typical applications include AC variable speed and servo motor drives, Static converters for DC motor drives, Battery supplied applications and Uninterruptible Power Supplies (UPS).
Key characteristics from the official datasheet: operating temperature −40 … 85 °C.
| General Information | |
|---|---|
| Manufacturer | LEM |
| Product Series | DVL |
| Product Reference | DVL 1000/SP7 |
| Nominal Primary Voltage | 1000 V |
| Supply Voltage | ±13.5 ... ±26.4 V |
| Measurement | voltage: DC, AC, pulsed... |
| Mounting | — |
| Application Domain | Railway (fixed installations and onboard), Industrial |
| Electrical Data — DVL 1000/SP7 | |
|---|---|
| Primary Nominal RMS Voltage (UPN) | 1000 V |
| Primary Voltage, Measuring Range (UPM) | −1500 ... 1500 V |
| Measuring Resistance (RM) | 0 ... 133 Ω |
| Secondary Nominal RMS Current (ISN) | 50 mA |
| Secondary Current (IS) | −75 ... 75 mA |
| Supply Voltage (±UC) | ±13.5 ... ±26.4 V |
| Rise Time of UC (10-90 %) | 100 ms |
| Current Consumption (IC) @ ±24 V, UP = 0 V | 20 ... 25 mA |
| Offset Current (IO) @ 25 °C | −50 ... 50 µA (100 % tested) |
| Temperature Variation of IO (IO T) @ −40 ... 85 °C | −150 ... 150 µA (−40 ... 85 °C) |
| Sensitivity (S) | 50 µA/V (50 mA for primary 1000 V) |
| Resistance of Primary Winding (RP) | 11.3 MΩ |
| Total Primary Power Loss @ UPN | 0.09 mW |
| Insulation Coordination | |
|---|---|
| RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud | 8.5 kV |
| Impulse Withstand Voltage (1.2/50 µs) UNi | 16 kV |
| Partial Discharge Test Voltage (q < 10 pC) Um t | 2700 V |
| Insulation Resistance (RINS) | 200 MΩ (measured at 500 V DC) |
| Case Material | V0 according to UL 94 |
| Comparative Tracking Index (CTI) | 600 |
| Environmental & Mechanical Characteristics | |
|---|---|
| Ambient Operating Temperature (TA) | −40 ... 85 °C |
| Ambient Storage Temperature (TA st) | −50 ... 90 °C |
| Equipment Operating Temperature Class (EN 50155) | OT6 |
| Switch-on Extended Operating Temperature Class (EN 50155) | ST0 |
| Rapid Temperature Variation Class (EN 50155) | H2 |
| Conformal Coating Type (EN 50155) | PC2 |
| Mass (m) | 470 g |
| Standards & Certifications | |
|---|---|
| EN 50155 | 2021 |
| EN 50178 | 1997 |
| EN 50124-1 | 2017 |
| EN 50121-3-2 | 2016 |
| UL 508 | 2013 |
| IEC 61010-1 | 2010/AMD1: 2016 |
| Accuracy & Dynamic Performance | |
|---|---|
| Sensitivity Error (εS) | −0.2 ... 0.2 % |
| Temperature Variation of Sensitivity Error (εS T) | −0.5 ... 0.5 % |
| Linearity Error (εL) | −0.5 ... 0.5 % of UPM |
| Total Error (εtot) @ 25 °C | −0.5 ... 0.5 % of UPN (25 °C, 100 % tested) |
| Total Error (εtot) @ −40 ... 85 °C | −1 ... 1 % of UPN (−40 ... 85 °C) |
| RMS Noise Current referred to primary (Ino) | 10 µA (1 Hz to 100 kHz) |
| Delay Time to 10 % of Final Output (tD 10) | 30 µs |
| Delay Time to 90 % of Final Output (tD 90) | 50 ... 60 µs |
| Frequency Bandwidth (−3 dB) | 14 kHz (−3 dB) |
| Frequency Bandwidth (−1 dB) | 8 kHz (−1 dB) |
| Frequency Bandwidth (−0.1 dB) | 2 kHz (−0.1 dB) |
| Start-up Time (tstart) | 190 ... 250 ms |
| RAMS Data | |
|---|---|
| Useful Life Class (EN 50155) | L4 |
| Mean Failure Rate (λ) | 1/1835004 h⁻¹ (EN 50155, U_C = ±24 V) |
Note: Specifications are taken from the official DVL 1000/SP7 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.
Official technical documentation for the DVL 1000/SP7.
Outline dimensions, pin layout and connection diagrams of the DVL 1000/SP7 are shown below.
| Outline Dimensions & Mechanical Data | |
|---|---|
| Mass | 470 g |
| Resistance of Primary Winding (RP) | 11.3 MΩ |
| Case Material | V0 according to UL 94 |
Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.
Typical applications of the DVL 1000/SP7.
The characteristic curves of the DVL 1000/SP7 from the official datasheet are shown below.
| Accuracy & Dynamic Characteristics | |
|---|---|
| Rise Time of UC (10-90 %) | 100 ms |
| Sensitivity (S) | 50 µA/V (50 mA for primary 1000 V) |
| Sensitivity Error (εS) | −0.2 ... 0.2 % |
| Temperature Variation of Sensitivity Error (εS T) | −0.5 ... 0.5 % |
| Linearity Error (εL) | −0.5 ... 0.5 % of UPM |
| Total Error (εtot) @ 25 °C | −0.5 ... 0.5 % of UPN (25 °C, 100 % tested) |
| Total Error (εtot) @ −40 ... 85 °C | −1 ... 1 % of UPN (−40 ... 85 °C) |
| Frequency Bandwidth (−3 dB) | 14 kHz (−3 dB) |
| Frequency Bandwidth (−1 dB) | 8 kHz (−1 dB) |
Note: Refer to the datasheet for the complete set of characteristic curves.