Your Trusted Source for Industrial Electrical Components
Home Products LEM Voltage Sensors DVL Series DVL 1000/SP7

DVL 1000/SP7

Voltage transducer

LEM | DVL-Series | EN 50155

1000 VNominal Primary Voltage
±13.5 ... ±26.4 VPower Supply
14 kHz (−3 dB)Bandwidth (-3dB)
−0.5 ... 0.5 % of UPN (25 °C, 100 % tested)Overall Accuracy @ 25 °C
0 ... 133 ΩMeasuring Resistance (RM)

Additional Technical Details

View Full Specifications
Primary Voltage, Measuring Range−1500 ... 1500 V
Secondary Nominal RMS Current50 mA
Sensitivity50 µA/V
Offset Current @ 25 °C−50 ... 50 µA (100 % tested)
Isolation Test Voltage8.5 kV
Operating Temperature Range−40 ... 85 °C

Standards & Approvals

  • EN 50155: 2021
  • EN 50178: 1997
  • EN 50124-1: 2017
  • EN 50121-3-2: 2016
  • UL 508: 2013
  • IEC 61010-1:2010/AMD1: 2016

Typical Applications

AC variable speed and servo motor drives, Static converters for DC motor drives, Battery supplied applications, Uninterruptible Power Supplies (UPS), Switched Mode Power Supplies (SMPS), Power supplies for welding applications, Renewable Energy (Solar and Wind), Propulsion and braking choppers, Propulsion converters, Auxiliary converters, High power drives, Substations.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The DVL 1000/SP7 is a None current transducer from LEM for the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation.

It offers excellent accuracy. Typical applications include AC variable speed and servo motor drives, Static converters for DC motor drives, Battery supplied applications and Uninterruptible Power Supplies (UPS).

Key characteristics from the official datasheet: operating temperature −40 … 85 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesDVL
Product ReferenceDVL 1000/SP7
Nominal Primary Voltage1000 V
Supply Voltage±13.5 ... ±26.4 V
Measurementvoltage: DC, AC, pulsed...
Mounting—
Application DomainRailway (fixed installations and onboard), Industrial
Electrical Data — DVL 1000/SP7
Primary Nominal RMS Voltage (UPN)1000 V
Primary Voltage, Measuring Range (UPM)−1500 ... 1500 V
Measuring Resistance (RM)0 ... 133 Ω
Secondary Nominal RMS Current (ISN)50 mA
Secondary Current (IS)−75 ... 75 mA
Supply Voltage (±UC)±13.5 ... ±26.4 V
Rise Time of UC (10-90 %)100 ms
Current Consumption (IC) @ ±24 V, UP = 0 V20 ... 25 mA
Offset Current (IO) @ 25 °C−50 ... 50 µA (100 % tested)
Temperature Variation of IO (IO T) @ −40 ... 85 °C−150 ... 150 µA (−40 ... 85 °C)
Sensitivity (S)50 µA/V (50 mA for primary 1000 V)
Resistance of Primary Winding (RP)11.3 MΩ
Total Primary Power Loss @ UPN0.09 mW
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud8.5 kV
Impulse Withstand Voltage (1.2/50 µs) UNi16 kV
Partial Discharge Test Voltage (q < 10 pC) Um t2700 V
Insulation Resistance (RINS)200 MΩ (measured at 500 V DC)
Case MaterialV0 according to UL 94
Comparative Tracking Index (CTI)600
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−40 ... 85 °C
Ambient Storage Temperature (TA st)−50 ... 90 °C
Equipment Operating Temperature Class (EN 50155)OT6
Switch-on Extended Operating Temperature Class (EN 50155)ST0
Rapid Temperature Variation Class (EN 50155)H2
Conformal Coating Type (EN 50155)PC2
Mass (m)470 g
Standards & Certifications
EN 501552021
EN 501781997
EN 50124-12017
EN 50121-3-22016
UL 5082013
IEC 61010-12010/AMD1: 2016
Accuracy & Dynamic Performance
Sensitivity Error (εS)−0.2 ... 0.2 %
Temperature Variation of Sensitivity Error (εS T)−0.5 ... 0.5 %
Linearity Error (εL)−0.5 ... 0.5 % of UPM
Total Error (εtot) @ 25 °C−0.5 ... 0.5 % of UPN (25 °C, 100 % tested)
Total Error (εtot) @ −40 ... 85 °C−1 ... 1 % of UPN (−40 ... 85 °C)
RMS Noise Current referred to primary (Ino)10 µA (1 Hz to 100 kHz)
Delay Time to 10 % of Final Output (tD 10)30 µs
Delay Time to 90 % of Final Output (tD 90)50 ... 60 µs
Frequency Bandwidth (−3 dB)14 kHz (−3 dB)
Frequency Bandwidth (−1 dB)8 kHz (−1 dB)
Frequency Bandwidth (−0.1 dB)2 kHz (−0.1 dB)
Start-up Time (tstart)190 ... 250 ms
RAMS Data
Useful Life Class (EN 50155)L4
Mean Failure Rate (λ)1/1835004 h⁻¹ (EN 50155, U_C = ±24 V)

Note: Specifications are taken from the official DVL 1000/SP7 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the DVL 1000/SP7 are shown below.

DVL 1000/SP7 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM DVL 1000/SP7 datasheet
Outline Dimensions & Mechanical Data
Mass470 g
Resistance of Primary Winding (RP)11.3 MΩ
Case MaterialV0 according to UL 94

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the DVL 1000/SP7.

AC variable speed and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Renewable Energy (Solar and Wind)

Characteristic Curves

The characteristic curves of the DVL 1000/SP7 from the official datasheet are shown below.

DVL 1000/SP7 characteristic curves
Characteristic curves — source: LEM DVL 1000/SP7 datasheet
Accuracy & Dynamic Characteristics
Rise Time of UC (10-90 %)100 ms
Sensitivity (S)50 µA/V (50 mA for primary 1000 V)
Sensitivity Error (εS)−0.2 ... 0.2 %
Temperature Variation of Sensitivity Error (εS T)−0.5 ... 0.5 %
Linearity Error (εL)−0.5 ... 0.5 % of UPM
Total Error (εtot) @ 25 °C−0.5 ... 0.5 % of UPN (25 °C, 100 % tested)
Total Error (εtot) @ −40 ... 85 °C−1 ... 1 % of UPN (−40 ... 85 °C)
Frequency Bandwidth (−3 dB)14 kHz (−3 dB)
Frequency Bandwidth (−1 dB)8 kHz (−1 dB)

Note: Refer to the datasheet for the complete set of characteristic curves.