Your Trusted Source for Industrial Electrical Components
Home Products LEM Voltage Sensors DV Series DVM 1000

DVM 1000

Voltage Transducer DVM series U = 600 ... 1000 V

LEM | DVM-Series | EN 50155

600 VNominal Primary Voltage
1000 VNominal Primary Current
±10.8 ... ±26.4 VPower Supply
−0.5 ... 0.5 % of IPNLinearity Error (Max)
−0.6 / Max 0.6 VNominal Primary Voltage

Additional Technical Details

View Full Specifications
Supply Voltage±10.8 ... ±26.4 V
Operating Temperature Range−40 ... 85 °C
Isolation Test Voltage12 kV
Primary Nominal RMS Current (IPN)1000 V
Current Consumption (IC)40 mA
Resistance of Primary Winding (RP)5.5 MΩ

Standards & Approvals

  • EN 50155:
  • EN 50121-3-2:
  • EN 50124-1:
  • IEC 62497-1:
  • IEC 61010-1: 2010 / Amd1:
  • IEC 62477-1:
  • UL 347: 2016.

Typical Applications

Single or three phase inverters, Propulsion and braking choppers, Propulsion converters, Auxiliary converters, High power drives, Substations. Standards, EN 50155: 2021, EN 50121-3-2: 2016, EN 50124-1: 2017, IEC 62497-1: 2010, IEC 61010-1: 2010 / Amd1: 2016, IEC 62477-1: 2012, UL 347: 2016. Application Domains, Industrial, Railway (fixed installations and onboard). Note: 1) Except for DVM 600. Page 1/13 LEM International SA notice www.lem.com

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The DVM 1000 is a None current transducer from LEM for the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation.

It offers excellent accuracy and low temperature drift. Typical applications include Single or three phase inverters, Propulsion and braking choppers, Propulsion converters and Auxiliary converters.

Key characteristics from the official datasheet: linearity error −0.5 ... 0.5 % of IPN; operating temperature −40 ... 85 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesDVM
Product ReferenceDVM 1000
Nominal Primary Voltage600 V
Primary Nominal Current1000 V
Supply Voltage±10.8 ... ±26.4 V
Measurementvoltage: DC, AC, pulsed...
Mounting—
Application DomainIndustrial, Railway (fixed installations and onboard)
Electrical Data — DVM 1000
Primary Nominal RMS Current (IPN)1000 V
Supply Voltage (UC)±10.8 ... ±26.4 V
Current Consumption (IC)40 mA
Resistance of Primary Winding (RP)5.5 MΩ
Primary nominal DC voltage (continuous) (UPNDC)Typ 600 V
Primary nominal AC RMS voltage (continuous) (UPNAC)Typ 600 V
Primary voltage, measuring range (UPM)Min −900 / Max 900 V
Measuring resistance (RM)Min 0 Ω
Secondary current (IS)Typ 50 mA
⎓ DC supply voltage (UC)Min ±10.8 / Typ ±12 ... ±24 / Max ±26.4 V
Rise time of (10 % ... 90 %) U C (trise)Max 100 ms
Total error (εtot)Min −1 / Max 1 %
Temperature variation of referred to primary U O E (UTOE)Min −1.20 / Max 1.20 V
Electrical Offset voltage referred to primary (UOE)Min −0.6 / Max 0.6 V
Sensitivity (S)Typ 83.33 µA/V
Sensitivity error (εS)Min −0.3 / Max 0.3 %
Temperature variation of sensitivity error (εTS)Min −0.5 / Max 0.5 %
Linearity error (εL)Min −0.5 / Max 0.5 U % of P N
RMS noise current 100 Hz ... 100 kHz referred to secondary (Ino)Typ 30 µA
Delay time @ 10 % of the final output value for step U P N (tD10)Typ 30 µs
Delay time @ 90 % of the final output value for step U P N (tD90)Typ 50 / Max 60 µs
Start-up time (tstart)Typ 190 / Max 250 ms
Resistance of primary (RP)Typ 5.5 MΩ
Absolute Maximum Ratings
⎓ Maximum DC supply voltage (U = 0 V, 0.1 s) P (±ÛCmax)±33.6 V
Absolute Maximum Ratings
⎓ Maximum DC supply voltage (working) (− 40 … + 85 °C) (±UCmax)±26.4 V
Absolute Maximum Ratings
Electrostatic discharge voltage (HBM - Human Body Model) (UESDHBM)4 kV
Absolute Maximum Ratings
Maximum DC common mode voltage (UU+HV+HV−|UUand−|HV+HV−)≤ 6.3 U ≤ P M kV
Accuracy & Dynamic Performance
Linearity Error (εL)−0.5 ... 0.5 % of IPN
Electrical Offset Voltage (VO E) @ IP = 0−1.0 ... 1.0 V
Response Time to 90 % of IPN Step50 ... 60 µs
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud12 kV
Impulse Withstand Voltage (1.2/50 µs) UNi30 kV
Creepage Distance (dCp)63 mm
Clearance (dCI)48 mm
Comparative Tracking Index (CTI)600
RMS voltage for AC insulation test, 50 Hz, 1 min (Ud)12 kV
Impulse withstand voltage 1.2/50 μs (UNi)30 kV
(q Partial discharge RMS test voltage < 10 pC) m (Ut)5000 V
Case materialV0
Application example RMS voltage line-to-neutral1000 V
Application example System voltage RMS3600 V
Application example Rated insulation RMS voltage (UNm)4800 V
Application example Rated insulation RMS voltage1000 V
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−40 ... 85 °C
Ambient Storage Temperature (TA st)−50 ... 90 °C
Mass (m)375 g
Ingress protection ratingTyp IP40
Pollution degreeMax PD4
AltitudeMax 1) 2000 m
Impact ratingTyp IK06
Mean failure rate (λ)Typ 1/1827550 h−1
Standards & Certifications
EN 50155Compliance
EN 50121-3-2Compliance
EN 50124-1Compliance
IEC 62497-1Compliance
IEC 61010-12010 / Amd1:
IEC 62477-1Compliance
UL 3472016.

Note: Specifications are taken from the official DVM 1000 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the DVM 1000 are shown below.

DVM 1000 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM DVM 1000 datasheet
Outline Dimensions & Mechanical Data
Mass375 g
Resistance of Primary Winding (RP)5.5 MΩ
Case materialV0
Ingress protection ratingTyp IP40

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the DVM 1000.

Single or three phase inverters
Propulsion and braking choppers
Propulsion converters
Auxiliary converters
High power drives
Substations. Standards
EN 50155: 2021

Characteristic Curves

The characteristic curves of the DVM 1000 from the official datasheet are shown below.

DVM 1000 characteristic curves
Characteristic curves — source: LEM DVM 1000 datasheet
Accuracy & Dynamic Characteristics
Rise time of (10 % ... 90 %) U C (trise)Max 100 ms
Total error (εtot)Min −1 / Max 1 %
Sensitivity (S)Typ 83.33 µA/V
Sensitivity error (εS)Min −0.3 / Max 0.3 %
Temperature variation of sensitivity error (εTS)Min −0.5 / Max 0.5 %
Linearity error (εL)Min −0.5 / Max 0.5 U % of P N
Response Time to 90 % of IPN Step50 ... 60 µs

Note: Refer to the datasheet for the complete set of characteristic curves.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment