Your Trusted Source for Industrial Electrical Components
Home Products LEM Voltage Sensors DV Series DVM 4000-B

DVM 4000-B

Voltage Transducer DVM-B series U = 2000 ... 4000 V

LEM | DVM-Series | EN 50155

2000 VNominal Primary Voltage
4000 VNominal Primary Current
±13.5 ... ±26.4 VPower Supply
−0.5 ... 0.5 % of IPNLinearity Error (Max)
−2.1 / Max 2.1 VNominal Primary Voltage

Additional Technical Details

View Full Specifications
Supply Voltage±13.5 ... ±26.4 V
Operating Temperature Range−40 ... 85 °C
Isolation Test Voltage12 kV
Primary Nominal RMS Current (IPN)4000 V
Current Consumption (IC)40 mA
Resistance of Primary Winding (RP)25.1 MΩ

Standards & Approvals

  • EN 50155:
  • EN 50121-3-2:
  • EN 50124-1:
  • IEC 62497-1:

Typical Applications

EN 50155: 2021, EN 50121-3-2: 2016, EN 50124-1: 2017, IEC 62497-1: 2010, IUL 347 1): 2016. Application Domain, Industrial, Railway (fixed installations and onboard). Note: When used with UL 347 Isolator N° 92.24.06.420.0. Page 1/13 out modifications on its transducers, L 1E 1M I Mn dt ee yr n ria nat nio t-n da ’Al S vrA www.lem.com

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The DVM 4000-B is a None current transducer from LEM for the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation, delivering an instantaneous output voltage of Typ 6.66 V.

It offers excellent accuracy and low temperature drift. Typical applications include EN 50155: 2021, EN 50121-3-2: 2016, EN 50124-1: 2017 and IEC 62497-1: 2010.

Key characteristics from the official datasheet: linearity error −0.5 ... 0.5 % of IPN; operating temperature −40 ... 85 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesDVM
Product ReferenceDVM 4000-B
Nominal Primary Voltage2000 V
Primary Nominal Current4000 V
Supply Voltage±13.5 ... ±26.4 V
Measurementvoltage: DC, AC, pulsed...
Mounting—
Application DomainIndustrial, Railway (fixed installations and onboard)
Electrical Data — DVM 4000-B
Primary Nominal RMS Current (IPN)4000 V
Supply Voltage (UC)±13.5 ... ±26.4 V
Current Consumption (IC)40 mA
Resistance of Primary Winding (RP)25.1 MΩ
Primary nominal DC voltage (continuous) (UPNDC)Typ 2000 V
Primary nominal AC RMS voltage (continuous) (UPNAC)Typ 2000 V
Primary voltage, measuring range (UPM)Min −3000 / Max 3000 V
Measuring resistance (RM)Min 2000 Ω
Secondary voltage (US)Typ 6.66 V
⎓ DC supply voltage (UC)Min ±13.5 / Typ ±24 / Max ±26.4 V
Rise time of (10 % ... 90 %) U C (trise)Max 100 ms
Total error (εtot)Min −1 / Max 1 %
Temperature variation of referred to primary U O E (UTOE)Min −7.5 / Max 7.5 V
Electrical Offset voltage referred to primary (UOE)Min −2.1 / Max 2.1 V
Sensitivity (S)Typ 3.33 mV/V
Sensitivity error (εS)Min −0.3 / Max 0.3 %
Temperature variation of sensitivity error (εTS)Min −0.5 / Max 0.5 %
Linearity error (εL)Min −0.5 / Max 0.5 U % of P M
RMS noise current 100 Hz ... 100 kHz referred to secondary (Uno)Typ 2.4 mV
Start-up time (tstart)Typ 190 / Max 250 ms
Resistance of primary (RP)Typ 25.1 MΩ
Absolute Maximum Ratings
⎓ Maximum DC supply voltage (U = 0 V, 0.1 s) P (±ÛCmax)±33.6 V
Absolute Maximum Ratings
⎓ Maximum DC supply voltage (working) (− 40 … + 85 °C) (±UCmax)±26.4 V
Absolute Maximum Ratings
Electrostatic discharge voltage (HBM - Human Body Model) (UESDHBM)4 kV
Absolute Maximum Ratings
Maximum DC common mode voltage (UU+HV+HV−|UUand−|HV+HV−)≤ 6.3 U ≤ P M kV
Accuracy & Dynamic Performance
Linearity Error (εL)−0.5 ... 0.5 % of IPN
Electrical Offset Voltage (VO E) @ IP = 0−4.2 ... 4.2 V
Response Time to 90 % of IPN Step50 ... 60 µs
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud12 kV
Impulse Withstand Voltage (1.2/50 µs) UNi30 kV
Creepage Distance (dCp)101 mm
Clearance (dCI)74 mm
Comparative Tracking Index (CTI)600
Mean failure rate (λ)Typ 1/1827550 h−1
RMS voltage for AC insulation test, 50 Hz, 1 min (Ud)12 kV
Impulse withstand voltage 1.2/50 μs (UNi)30 kV
(q Partial discharge RMS test voltage < 10 pC) m (Ut)5000 V
Case materialV0
Application example RMS voltage line-to-neutral1000 V
Application example System voltage RMS3600 V
Application example Rated insulation RMS voltage (UNm)4800 V
Application example Rated insulation RMS voltage1000 V
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−40 ... 85 °C
Ambient Storage Temperature (TA st)−50 ... 90 °C
Mass (m)375 g
Ingress protection ratingTyp IP40
Pollution degreeMax PD4
AltitudeMax 1) 2000 m
Impact ratingTyp IK06
Standards & Certifications
EN 50155Compliance
EN 50121-3-2Compliance
EN 50124-1Compliance
IEC 62497-1Compliance

Note: Specifications are taken from the official DVM 4000-B datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the DVM 4000-B are shown below.

DVM 4000-B outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM DVM 4000-B datasheet
Outline Dimensions & Mechanical Data
Mass375 g
Resistance of Primary Winding (RP)25.1 MΩ
Case materialV0
Ingress protection ratingTyp IP40

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the DVM 4000-B.

EN 50155: 2021
EN 50121-3-2: 2016
EN 50124-1: 2017
IEC 62497-1: 2010
IUL 347 1): 2016. Application Domain
Industrial
Railway (fixed installations and onboard). Note: When used with UL 347 Isolator N° 92.24.06.420.0. Page 1/13 out modifications on its transducers, L 1E 1M I Mn dt ee yr n ria nat nio t-n da ’Al S vrA www.lem.com

Characteristic Curves

The characteristic curves of the DVM 4000-B from the official datasheet are shown below.

DVM 4000-B characteristic curves
Characteristic curves — source: LEM DVM 4000-B datasheet
Accuracy & Dynamic Characteristics
Secondary voltage (US)Typ 6.66 V
Rise time of (10 % ... 90 %) U C (trise)Max 100 ms
Total error (εtot)Min −1 / Max 1 %
Sensitivity (S)Typ 3.33 mV/V
Sensitivity error (εS)Min −0.3 / Max 0.3 %
Temperature variation of sensitivity error (εTS)Min −0.5 / Max 0.5 %
Linearity error (εL)Min −0.5 / Max 0.5 U % of P M
Response Time to 90 % of IPN Step50 ... 60 µs

Note: Refer to the datasheet for the complete set of characteristic curves.