Your Trusted Source for Industrial Electrical Components

LA 25-NP/SP34

Closed loop (compensated) current transducer using the Hall effect

LEM | LA-Series | Closed loop (compensated) | EN 50155 | PCB Mount

1.5 ANominal Primary Current
±15 VPower Supply
Closed loop (compensated)Technology
DC ... 150 kHzBandwidth (-1dB)
±0.6 %Total Error @ IPN

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range0 ... ±2.2 A
Secondary Nominal Current24 mA
Supply Voltage±15 V
Operating Temperature Range−40 ... +85
Isolation Test Voltage2.5 kV
Primary Nominal RMS Current (IPN)1.5 A

Standards & Approvals

  • EN 50155: 2017

Typical Applications

Single or phase inverters, Propulsion and braking chopper, MPropulsion converter, Auxiliary converter, Battery charger.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The LA 25-NP/SP34 is a closed loop (compensated) current transducer from LEM for the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation.

It offers excellent accuracy, very good linearity, low temperature drift and wide frequency bandwidth. Typical applications include Single or phase inverters, Propulsion and braking chopper, MPropulsion converter and Auxiliary converter.

Key characteristics from the official datasheet: total error ±0.6 %; linearity error < 0.2 %; frequency bandwidth DC ... 150 kHz; operating temperature −40 ... +85; nominal secondary output 24 mA.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesLA
Product ReferenceLA 25-NP/SP34
Primary Nominal Current1.5 A
Supply Voltage±15 V
Measurementcurrents: DC, AC, pulsed...
MountingPCB Mount
Application DomainRailway
Electrical Data — LA 25-NP/SP34
Primary Nominal RMS Current (IPN)1.5 A
Primary Current, Measuring Range (IPM)0 ... ±2.2 A
Secondary Nominal RMS Current (ISN)24 mA
Turns Ratio (NP/NS)16 : 1000
Supply Voltage (UC)±15 V
Current Consumption (IC)10 + I 11 + I mA
Accuracy & Dynamic Performance
Total Error (εtot) @ IPN±0.6 %
Linearity Error (εL)< 0.2 %
Frequency Bandwidth (BW)DC ... 150 kHz
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud2.5 kV
Impulse Withstand Voltage (1.2/50 µs) UNi16 kV
Creepage Distance (dCp)19.5 mm
Clearance (dCI)19.5 mm
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−40 ... +85
Ambient Storage Temperature (TA st)−45 ... +90 °C
Mass (m)22 g
Case MaterialInsulating plastic case recognized according to UL 94-V0.
Recommended PCB Hole1.2 mm
General Tolerance±0.2 mm
Standards & Certifications
EN 501552017

Note: Specifications are taken from the official LA 25-NP/SP34 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the LA 25-NP/SP34 are shown below.

LA 25-NP/SP34 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM LA 25-NP/SP34 datasheet, page 3
Outline Dimensions & Mechanical Data
Recommended PCB Hole1.2 mm
General Tolerance±0.2 mm
Mass22 g
Case MaterialInsulating plastic case recognized according to UL 94-V0.

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the LA 25-NP/SP34.

Single or phase inverters
Propulsion and braking chopper
MPropulsion converter
Auxiliary converter
Battery charger

Characteristic Curves

Characteristic curve diagrams are not included in the LA 25-NP/SP34 datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Accuracy & Dynamic Characteristics
Total Error (εtot) @ IPN±0.6 %
Linearity Error (εL)< 0.2 %
Frequency Bandwidth (BW)DC ... 150 kHz

Note: For the full set of performance data, refer to the datasheet.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment