Authorized Distributor
?
Closed loop (compensated) current transducer using the Hall effect
| Primary Current, Measuring Range | 0 ... ±2.2 A |
| Secondary Nominal Current | 24 mA |
| Supply Voltage | ±15 V |
| Operating Temperature Range | −40 ... +85 |
| Isolation Test Voltage | 2.5 kV |
| Primary Nominal RMS Current (IPN) | 1.5 A |
Single or phase inverters, Propulsion and braking chopper, MPropulsion converter, Auxiliary converter, Battery charger.
The LA 25-NP/SP34 is a closed loop (compensated) current transducer from LEM for the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation.
It offers excellent accuracy, very good linearity, low temperature drift and wide frequency bandwidth. Typical applications include Single or phase inverters, Propulsion and braking chopper, MPropulsion converter and Auxiliary converter.
Key characteristics from the official datasheet: total error ±0.6 %; linearity error < 0.2 %; frequency bandwidth DC ... 150 kHz; operating temperature −40 ... +85; nominal secondary output 24 mA.
| General Information | |
|---|---|
| Manufacturer | LEM |
| Product Series | LA |
| Product Reference | LA 25-NP/SP34 |
| Primary Nominal Current | 1.5 A |
| Supply Voltage | ±15 V |
| Measurement | currents: DC, AC, pulsed... |
| Mounting | PCB Mount |
| Application Domain | Railway |
| Electrical Data — LA 25-NP/SP34 | |
|---|---|
| Primary Nominal RMS Current (IPN) | 1.5 A |
| Primary Current, Measuring Range (IPM) | 0 ... ±2.2 A |
| Secondary Nominal RMS Current (ISN) | 24 mA |
| Turns Ratio (NP/NS) | 16 : 1000 |
| Supply Voltage (UC) | ±15 V |
| Current Consumption (IC) | 10 + I 11 + I mA |
| Accuracy & Dynamic Performance | |
|---|---|
| Total Error (εtot) @ IPN | ±0.6 % |
| Linearity Error (εL) | < 0.2 % |
| Frequency Bandwidth (BW) | DC ... 150 kHz |
| Insulation Coordination | |
|---|---|
| RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud | 2.5 kV |
| Impulse Withstand Voltage (1.2/50 µs) UNi | 16 kV |
| Creepage Distance (dCp) | 19.5 mm |
| Clearance (dCI) | 19.5 mm |
| Environmental & Mechanical Characteristics | |
|---|---|
| Ambient Operating Temperature (TA) | −40 ... +85 |
| Ambient Storage Temperature (TA st) | −45 ... +90 °C |
| Mass (m) | 22 g |
| Case Material | Insulating plastic case recognized according to UL 94-V0. |
| Recommended PCB Hole | 1.2 mm |
| General Tolerance | ±0.2 mm |
| Standards & Certifications | |
|---|---|
| EN 50155 | 2017 |
Note: Specifications are taken from the official LA 25-NP/SP34 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.
Official technical documentation for the LA 25-NP/SP34.
Outline dimensions, pin layout and connection diagrams of the LA 25-NP/SP34 are shown below.
| Outline Dimensions & Mechanical Data | |
|---|---|
| Recommended PCB Hole | 1.2 mm |
| General Tolerance | ±0.2 mm |
| Mass | 22 g |
| Case Material | Insulating plastic case recognized according to UL 94-V0. |
Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.
Typical applications of the LA 25-NP/SP34.
Characteristic curve diagrams are not included in the LA 25-NP/SP34 datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.
| Accuracy & Dynamic Characteristics | |
|---|---|
| Total Error (εtot) @ IPN | ±0.6 % |
| Linearity Error (εL) | < 0.2 % |
| Frequency Bandwidth (BW) | DC ... 150 kHz |
Note: For the full set of performance data, refer to the datasheet.