Authorized Distributor
?
Closed loop (compensated) current transducer using the Hall effect
| Primary Current, Measuring Range | 0 ... ±100 A |
| Secondary Nominal Current | 25 mA |
| Supply Voltage | ±12 ... 15 V |
| Operating Temperature Range | −40 ... +85 °C |
| Isolation Test Voltage | 3.6 kV |
| Primary Nominal RMS Current (IPN) | 50 A |
Single or three phase inverters, Propulsion and braking choppers, Propulsion converters, Auxiliary converters, Battery chargers.
The LA 55-TP/SP27 is a closed loop (compensated) current transducer from LEM for the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation.
It offers excellent accuracy, very good linearity, low temperature drift and wide frequency bandwidth. Typical applications include Single or three phase inverters, Propulsion and braking choppers, Propulsion converters and Auxiliary converters.
Key characteristics from the official datasheet: linearity error < 0.15 %; frequency bandwidth DC ... 200 kHz; operating temperature −40 ... +85 °C; nominal secondary output 25 mA.
| General Information | |
|---|---|
| Manufacturer | LEM |
| Product Series | LA |
| Product Reference | LA 55-TP/SP27 |
| Primary Nominal Current | 50 A |
| Supply Voltage | ±12 ... 15 V |
| Measurement | currents: DC, AC, pulsed... |
| Mounting | PCB Mount |
| Application Domain | Railway |
| Electrical Data — LA 55-TP/SP27 | |
|---|---|
| Primary Nominal RMS Current (IPN) | 50 A |
| Primary Current, Measuring Range (IPM) | 0 ... ±100 A |
| Secondary Nominal RMS Current (ISN) | 25 mA |
| Turns Ratio (NP/NS) | 1 : 2000 |
| Supply Voltage (UC) | ±12 ... 15 V |
| Current Consumption (IC) | (±2) 10 (@ ±15 V) + I mA P S C |
| Accuracy & Dynamic Performance | |
|---|---|
| Linearity Error (εL) | < 0.15 % |
| Frequency Bandwidth (BW) | DC ... 200 kHz |
| Insulation Coordination | |
|---|---|
| RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud | 3.6 kV |
| Impulse Withstand Voltage (1.2/50 µs) UNi | 7.5 kV |
| Comparative Tracking Index (CTI) | 600 |
| Environmental & Mechanical Characteristics | |
|---|---|
| Ambient Operating Temperature (TA) | −40 ... +85 °C |
| Ambient Storage Temperature (TA st) | −40 ... +90 °C |
| Mass (m) | 25 g |
| Case Material | Insulating plastic case recognized according to UL 94-V0. |
| Recommended PCB Hole | 3.8 mm |
| General Tolerance | ±0.2 mm |
| Standards & Certifications | |
|---|---|
| EN 50155 | Compliance |
Note: Specifications are taken from the official LA 55-TP/SP27 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.
Official technical documentation for the LA 55-TP/SP27.
Outline dimensions, pin layout and connection diagrams of the LA 55-TP/SP27 are shown below.
| Outline Dimensions & Mechanical Data | |
|---|---|
| Recommended PCB Hole | 3.8 mm |
| General Tolerance | ±0.2 mm |
| Mass | 25 g |
| Case Material | Insulating plastic case recognized according to UL 94-V0. |
Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.
Typical applications of the LA 55-TP/SP27.
Characteristic curve diagrams are not included in the LA 55-TP/SP27 datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.
| Accuracy & Dynamic Characteristics | |
|---|---|
| Linearity Error (εL) | < 0.15 % |
| Frequency Bandwidth (BW) | DC ... 200 kHz |
Note: For the full set of performance data, refer to the datasheet.