Your Trusted Source for Industrial Electrical Components
Home Products LEM Voltage Sensors LV25 Series LV 25-600/SP2

LV 25-600/SP2

Closed loop (compensated) voltage transducer using the Hall effect

LEM | LV-Series | EN 50155 | Busbar Mount

600 VNominal Primary Voltage
10 mANominal Primary Current
±12 ... 15 VPower Supply
±0.8 %Total Error @ IPN
< 0.2 %Linearity Error (Max)

Additional Technical Details

View Full Specifications
Secondary Nominal Current25 mA
Supply Voltage±12 ... 15 V
Operating Temperature Range−30 ... +70 °C
Isolation Test Voltage4.1 kV
Primary Nominal RMS Current (IPN)10 mA
Secondary Nominal RMS Current (ISN)25 mA

Standards & Approvals

  • EN 50155
  • UL 508

Typical Applications

AC variable speed drives and servo motor drives, Static converters for DC motor drives, Uninterruptible Power Supplies (UPS), Power supplies for welding applications. Application Domain, Railway (fixed installations and onboard).

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The LV 25-600/SP2 is a None current transducer from LEM for the electronic measurement of voltages: DC, AC, pulsed..., with galvanic isolation.

It offers excellent accuracy, very good linearity and low temperature drift. Typical applications include AC variable speed drives and servo motor drives, Static converters for DC motor drives, Uninterruptible Power Supplies (UPS) and Power supplies for welding applications. Application Domain.

Key characteristics from the official datasheet: total error ±0.8 %; linearity error < 0.2 %; operating temperature −30 ... +70 °C; nominal secondary output 25 mA.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesLV
Product ReferenceLV 25-600/SP2
Nominal Primary Voltage600 V
Primary Nominal Current10 mA
Supply Voltage±12 ... 15 V
Measurementvoltages: DC, AC, pulsed...
MountingBusbar Mount
Application DomainRailway (fixed installations and onboard)
Electrical Data — LV 25-600/SP2
Primary Nominal RMS Current (IPN)10 mA
Secondary Nominal RMS Current (ISN)25 mA
Turns Ratio (NP/NS)600 V : 25 mA
Supply Voltage (UC)±12 ... 15 V
Current Consumption (IC)10 (@ ±15 V) + I mA
Accuracy & Dynamic Performance
Total Error (εtot) @ IPN±0.8 %
Linearity Error (εL)< 0.2 %
Delay Time (tD)< 15 us
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud4.1 kV
Creepage Distance (dCp)13.8 mm
Clearance (dCI)13.8 mm
Comparative Tracking Index (CTI)175
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−30 ... +70 °C
Ambient Storage Temperature (TA st)−40 ... +85 °C
Mass (m)60 g
Case MaterialInsulating plastic case re Scogn Mized according to UL 94-V0
General Tolerance±0.3 mm
Standards & Certifications
EN 50155Compliance
UL 508Compliance

Note: Specifications are taken from the official LV 25-600/SP2 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the LV 25-600/SP2 are shown below.

LV 25-600/SP2 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM LV 25-600/SP2 datasheet, page 3
Outline Dimensions & Mechanical Data
General Tolerance±0.3 mm
Mass60 g
Case MaterialInsulating plastic case re Scogn Mized according to UL 94-V0

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the LV 25-600/SP2.

AC variable speed drives and servo motor drives
Static converters for DC motor drives
Uninterruptible Power Supplies (UPS)
Power supplies for welding applications. Application Domain
Railway (fixed installations and onboard). Page 1/3 LEM International SA Chemin des Aulx 8 www.lem.com

Characteristic Curves

Characteristic curve diagrams are not included in the LV 25-600/SP2 datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Accuracy & Dynamic Characteristics
Total Error (εtot) @ IPN±0.8 %
Linearity Error (εL)< 0.2 %

Note: For the full set of performance data, refer to the datasheet.