Your Trusted Source for Industrial Electrical Components
Home Products LEM Voltage Sensors LV25 Series LV 25-P

LV 25-P

Closed loop (compensated) voltage transducer using the Hall effect

LEM | LV-Series | Closed loop (compensated) | EN 50178 | PCB Mount

10 mANominal Primary Current
±12 … 15 VPower Supply
Closed loop (compensated)Technology
< 0.2 %Linearity Error (Max)
16 kVImpulse Withstand Voltage

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range0 … ±14 mA
Secondary Nominal Current25 mA
Supply Voltage±12 … 15 V
Operating Temperature Range0 … +70 °C
Primary Nominal RMS Current (IPN)10 mA
Secondary Nominal RMS Current (ISN)25 mA

Standards & Approvals

  • EN 50178
  • UL 508

Typical Applications

AC variable speed drives and servo motor drives, Static converters for DC motor drives, Battery supplied applications, Uninterruptible Power Supplies (UPS), Power supplies for welding applications.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The LV 25-P is a closed loop (compensated) current transducer from LEM for the electronic measurement of voltages: DC, AC, pulsed..., U = 10 ... 500 V d d, with galvanic isolation.

It offers excellent accuracy and very good linearity. Typical applications include AC variable speed drives and servo motor drives, Static converters for DC motor drives, Battery supplied applications and Uninterruptible Power Supplies (UPS).

Key characteristics from the official datasheet: linearity error < 0.2 %; operating temperature 0 … +70 °C; nominal secondary output 25 mA.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesLV
Product ReferenceLV 25-P
Primary Nominal Current10 mA
Supply Voltage±12 … 15 V
Measurementvoltages: DC, AC, pulsed..., U = 10 ... 500 V d d
MountingPCB Mount
Application DomainIndustrial
Electrical Data — LV 25-P
Primary Nominal RMS Current (IPN)10 mA
Primary Current, Measuring Range (IPM)0 … ±14 mA
Secondary Nominal RMS Current (ISN)25 mA
Turns Ratio (NP/NS)2500 : 1000
Supply Voltage (UC)±12 … 15 V
Current Consumption (IC)10 (@ ±15 V) + I mA resistor R which is selected by
Accuracy & Dynamic Performance
Linearity Error (εL)< 0.2 %
Insulation Coordination
Impulse Withstand Voltage (1.2/50 µs) UNi16 kV
Creepage Distance (dCp)19.5 mm
Clearance (dCI)19.5 mm
Comparative Tracking Index (CTI)175
Rated Insulation Voltage (basic)1600 V
Rated Insulation Voltage (reinforced)800 V
Overvoltage Category / Pollution DegreeOver voltage category OV · Pollution degree PD2
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)0 … +70 °C
Ambient Storage Temperature (TA st)−25 … +85 °C
Mass (m)22 g
Case MaterialInsulating plastic case recognized according to UL 94-V0.
Standards & Certifications
EN 50178Compliance
UL 508Compliance

Note: Specifications are taken from the official LV 25-P datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the LV 25-P are shown below.

LV 25-P outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM LV 25-P datasheet, page 4
Outline Dimensions & Mechanical Data
Mass22 g
Case MaterialInsulating plastic case recognized according to UL 94-V0.

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the LV 25-P.

AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Power supplies for welding applications

Characteristic Curves

Characteristic curve diagrams are not included in the LV 25-P datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Accuracy & Dynamic Characteristics
Linearity Error (εL)< 0.2 %

Note: For the full set of performance data, refer to the datasheet.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment