Your Trusted Source for Industrial Electrical Components
Home Products LEM Voltage Sensors LV25 Series LV 25-P/SP5

LV 25-P/SP5

Closed loop (compensated) voltage transducer using the Hall effect

LEM | LV-Series | Closed loop (compensated) | EN 50155 | PCB Mount

10 mANominal Primary Current
±15 VPower Supply
Closed loop (compensated)Technology
±0.8 %Total Error @ IPN
< 0.2 %Linearity Error (Max)

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range0 ... ±14 mA
Secondary Nominal Current25 mA
Supply Voltage±15 V
Operating Temperature Range−40 ... +85 °C
Isolation Test Voltage4.2 kV
Primary Nominal RMS Current (IPN)10 mA

Standards & Approvals

  • EN 50155: 2017
  • UL 508

Typical Applications

Single or three phase inverters, Propulsion and braking choppers, Propulsion converters, Auxiliary converters, Battery chargers. Application Domain, Railway (fixed installations and onboard).

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The LV 25-P/SP5 is a closed loop (compensated) current transducer from LEM for the electronic measurement of voltages: DC, AC, pulsed..., U = 10 ... 1500 V, with galvanic isolation.

It offers excellent accuracy, very good linearity, low temperature drift and wide frequency bandwidth. Typical applications include Single or three phase inverters, Propulsion and braking choppers, Propulsion converters and Auxiliary converters.

Key characteristics from the official datasheet: total error ±0.8 %; linearity error < 0.2 %; operating temperature −40 ... +85 °C; nominal secondary output 25 mA.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesLV
Product ReferenceLV 25-P/SP5
Primary Nominal Current10 mA
Supply Voltage±15 V
Measurementvoltages: DC, AC, pulsed..., U = 10 ... 1500 V
MountingPCB Mount
Application DomainRailway (fixed installations and onboard)
Electrical Data — LV 25-P/SP5
Primary Nominal RMS Current (IPN)10 mA
Primary Current, Measuring Range (IPM)0 ... ±14 mA
Secondary Nominal RMS Current (ISN)25 mA
Turns Ratio (NP/NS)2500 : 1000
Supply Voltage (UC)±15 V
Current Consumption (IC)10 + I mA
Accuracy & Dynamic Performance
Total Error (εtot) @ IPN±0.8 %
Linearity Error (εL)< 0.2 %
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud4.2 kV
Impulse Withstand Voltage (1.2/50 µs) UNi16 kV
Creepage Distance (dCp)19.5 mm
Clearance (dCI)19.5 mm
Comparative Tracking Index (CTI)175
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−40 ... +85 °C
Ambient Storage Temperature (TA st)−50 ... +90 °C
Mass (m)22 g
Case MaterialInsulating plastic case recognized according to UL 94-V0.
Standards & Certifications
EN 501552017
UL 508Compliance

Note: Specifications are taken from the official LV 25-P/SP5 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the LV 25-P/SP5 are shown below.

LV 25-P/SP5 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM LV 25-P/SP5 datasheet, page 4
Outline Dimensions & Mechanical Data
Mass22 g
Case MaterialInsulating plastic case recognized according to UL 94-V0.

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the LV 25-P/SP5.

Single or three phase inverters
Propulsion and braking choppers
Propulsion converters
Auxiliary converters
Battery chargers. Application Domain
Railway (fixed installations and onboard). Page 1/4 LEM International SA Route du Nant-d’Avril, 152 www.lem.com

Characteristic Curves

Characteristic curve diagrams are not included in the LV 25-P/SP5 datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Accuracy & Dynamic Characteristics
Total Error (εtot) @ IPN±0.8 %
Linearity Error (εL)< 0.2 %

Note: For the full set of performance data, refer to the datasheet.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment