Your Trusted Source for Industrial Electrical Components

AKR 2000 C420L J

AC Current Transducer

LEM | AKR-Series | Panel Mount

(Loop powered) 24 V DCPower Supply
10-400 HzBandwidth (-1dB)
±1 %Total Error @ IPN
±1 mmGeneral Tolerance
+50 °CAmbient operating temperature (0-95 % RH) −20 … (T)

Additional Technical Details

View Full Specifications
Supply Voltage(Loop powered) 24 V DC
Operating Temperature Range(0-95 % RH) −20 …
Frequency Bandwidth (BW)10-400 Hz
Ambient Operating Temperature (TA)(0-95 % RH) −20 …
Ambient Storage Temperature (TA st)−20 … +85 °C
Mass (m)450 g

Standards & Approvals

Typical Applications

Large Pumps Detect dry run electronically, Generation Measure the output of generators, Electric Heating Elements temperature transducers

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The AKR 2000 C420L J is a None current transducer from LEM.

Since it cannot saturate, very high and short-circuit currents are measured without degradation. Typical applications include Large Pumps Detect dry run electronically, Generation Measure the output of generators and Electric Heating Elements temperature transducers.

Key characteristics from the official datasheet: total error ±1 %; frequency bandwidth 10-400 Hz; operating temperature (0-95 % RH) −20 ….

Technical Specifications

General Information
ManufacturerLEM
Product SeriesAKR
Product ReferenceAKR 2000 C420L J
Supply Voltage(Loop powered) 24 V DC
Measurement—
MountingPanel Mount
Application DomainRenewable Energies and
Electrical Data — AKR 2000 C420L J
Supply Voltage (UC)(Loop powered) 24 V DC
Supply voltage (Loop powered) (U)24 V
Accuracy & Dynamic Performance
Total Error (εtot) @ IPN±1 %
Frequency Bandwidth (BW)10-400 Hz
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)(0-95 % RH) −20 …
Ambient Storage Temperature (TA st)−20 … +85 °C
Mass (m)450 g
General Tolerance±1 mm
Ambient operating temperature (0-95 % RH) −20 … (T)+50 °C
Ambient storage temperature −20 … (T)+85 °C
Sandards IEC 61010-1:2001
Insulation Coordination
RMS voltage for AC insulation test 1), 50 Hz (U)1 min 600 V
Route du Nant-d’Avril152

Note: Specifications are taken from the official AKR 2000 C420L J datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the AKR 2000 C420L J are shown below.

AKR 2000 C420L J outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM AKR 2000 C420L J datasheet, page 3
Outline Dimensions & Mechanical Data
General Tolerance±1 mm
Mass450 g

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the AKR 2000 C420L J.

Large Pumps Detect dry run electronically
Generation Measure the output of generators
Electric Heating Elements temperature transducers

Characteristic Curves

Characteristic curve diagrams are not included in the AKR 2000 C420L J datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Accuracy & Dynamic Characteristics
Total Error (εtot) @ IPN±1 %
Frequency Bandwidth (BW)10-400 Hz

Note: For the full set of performance data, refer to the datasheet.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment