Your Trusted Source for Industrial Electrical Components

AKR 50 C420L

AC Current Transducer

LEM | AKR-Series | Panel Mount

(Loop powered) 24 V DCPower Supply
10-400 HzBandwidth (-1dB)
(0-95 % RH) −20 …Ambient Operating Temperature (TA)
−20 … +85 °CAmbient Storage Temperature (TA st)
90 gMass (m)

Additional Technical Details

View Full Specifications
Supply Voltage(Loop powered) 24 V DC
Operating Temperature Range(0-95 % RH) −20 …
Isolation Test Voltage3 kV
Frequency Bandwidth (BW)10-400 Hz
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud3 kV
RMS voltage for AC insulation test 1), 50 Hz (U)1 min 3 kV

Standards & Approvals

Typical Applications

VFD Controlled Loads VFD output indicates how the motor and attached load are operating, SCR Silicon Controlled Loads Accurate measurement of phase angle fired or burst fired (time proportioned) SCRs, Switching Power Supplies and Electronic Ballasts True RMS sensing is the most accurate way to measure power supply or ballast input power. Options on request, DIN mounting

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The AKR 50 C420L is a None current transducer from LEM.

Since it cannot saturate, very high and short-circuit currents are measured without degradation. Typical applications include VFD Controlled Loads VFD output indicates how the motor and attached load are operating, SCR Silicon Controlled Loads Accurate measurement of phase angle fired or burst fired (time proportioned) SCRs, Switching Power Supplies and Electronic Ballasts True RMS sensing is the most accurate way to measure power supply or ballast input power. Options on request and DIN mounting.

Key characteristics from the official datasheet: frequency bandwidth 10-400 Hz; operating temperature (0-95 % RH) −20 ….

Technical Specifications

General Information
ManufacturerLEM
Product SeriesAKR
Product ReferenceAKR 50 C420L
Supply Voltage(Loop powered) 24 V DC
Measurement—
MountingPanel Mount
Application DomainRenewable Energies and
Electrical Data — AKR 50 C420L
Supply Voltage (UC)(Loop powered) 24 V DC
Supply voltage (Loop powered) (U)24 V
Accuracy & Dynamic Performance
Frequency Bandwidth (BW)10-400 Hz
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud3 kV
RMS voltage for AC insulation test 1), 50 Hz (U)1 min 3 kV
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)(0-95 % RH) −20 …
Ambient Storage Temperature (TA st)−20 … +85 °C
Mass (m)90 g
General Tolerance±1 mm
Ambient operating temperature (0-95 % RH) −20 … (T)+50 °C
Ambient storage temperature −20 … (T)+85 °C
Sandards Safety IEC 61010-1:2001
EMC EN 61326-1:2005

Note: Specifications are taken from the official AKR 50 C420L datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the AKR 50 C420L are shown below.

AKR 50 C420L outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM AKR 50 C420L datasheet
Outline Dimensions & Mechanical Data
General Tolerance±1 mm
Mass90 g

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the AKR 50 C420L.

VFD Controlled Loads VFD output indicates how the motor and attached load are operating
SCR Silicon Controlled Loads Accurate measurement of phase angle fired or burst fired (time proportioned) SCRs
Switching Power Supplies and Electronic Ballasts True RMS sensing is the most accurate way to measure power supply or ballast input power. Options on request
DIN mounting

Characteristic Curves

Characteristic curve diagrams are not included in the AKR 50 C420L datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Accuracy & Dynamic Characteristics
Frequency Bandwidth (BW)10-400 Hz

Note: For the full set of performance data, refer to the datasheet.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment