Your Trusted Source for Industrial Electrical Components
Home Products LEM Automotive Series DHAB Series DHAB S/160

DHAB S/160

Open Loop transducer using the Hall effect

LEM | DHAB-Series | Open Loop Transducer | Busbar Mount

± 50 A / ± 300 ANominal Primary Current
4.75 .. 5.25 VPower Supply
Open Loop TransducerTechnology
1.1 kHzBandwidth (-1dB)
15 .. 20 mACurrent Consumption (IC)

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range± 50 A / ± 300 A
Supply Voltage4.75 .. 5.25 V
Sensitivity40 / 6.67 mV/A
Operating Temperature Range−10 .. 65 °C / −40 .. 125 °C
Isolation Test Voltage2.5 kV
Primary Nominal Current (IPN)± 50 A / ± 300 A

Standards & Approvals

Typical Applications

Dual channel sensor for wider measurement range and d thickness of the Hall plate redundancy. I current across the Hall plates The measurement signal V amplified to supply the user output.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The DHAB S/160 is an open loop current transducer from LEM for the electronic measurement of DC, AC, or pulsed currents, with galvanic isolation, delivering an instantaneous output voltage of 2.5 V.

Typical applications include Dual channel sensor for wider measurement range and d thickness of the Hall plate redundancy. I current across the Hall plates The measurement signal V amplified to supply the user output.

Key characteristics from the official datasheet: frequency bandwidth 1.1 kHz; operating temperature −10 .. 65 °C / −40 .. 125 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesDHAB
Product ReferenceDHAB S/160
Primary Nominal Current± 50 A / ± 300 A
Supply Voltage4.75 .. 5.25 V
MeasurementDC, AC, or pulsed currents
MountingBusbar Mount
Application DomainDual channel sensor for wider measurement range and d thickness of the Hall plate redundancy
Electrical Data — DHAB S/160
Primary Nominal Current (IPN)± 50 A / ± 300 A
Primary Current, Measuring Range (IPM)± 50 A / ± 300 A
Supply Voltage (UC)4.75 .. 5.25 V
Current Consumption (IC)15 .. 20 mA
Sensitivity40 / 6.67 mV/A
Output Offset Voltage (VO E)2.5 V
Load Resistance (RL)10 kOhm
Insulation Resistance (RINS)500 MOhm
Accuracy & Dynamic Performance
Ratiometricity Error± 1 %
Frequency Bandwidth1.1 kHz
Output Noise± 10 mV
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud2.5 kV
Creepage Distance (dCp)3.1 mm
Clearance (dCI)3.1 mm
Comparative Tracking Index (CTI)PLC3
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−10 .. 65 °C / −40 .. 125 °C
Ambient Storage Temperature (TA st)−40 .. 125 °C
Mass (m)82 g

Note: Specifications are taken from the official DHAB S/160 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the DHAB S/160 are shown below.

DHAB S/160 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM DHAB S/160 datasheet
Outline Dimensions & Mechanical Data
Mass82 g

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the DHAB S/160.

Dual channel sensor for wider measurement range and d thickness of the Hall plate redundancy. I current across the Hall plates The measurement signal V amplified to supply the user output

Characteristic Curves

The characteristic curves of the DHAB S/160 from the official datasheet are shown below.

DHAB S/160 characteristic curves
Characteristic curves — source: LEM DHAB S/160 datasheet
Accuracy & Dynamic Characteristics
Sensitivity40 / 6.67 mV/A
Frequency Bandwidth1.1 kHz
Reference Conditions
Ambient Temperature (TA)25 °C, unless otherwise noted
Output Load Resistance (RL)10 kOhm

Note: Refer to the datasheet for the complete set of characteristic curves.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment