± 100 ANominal Primary Current
4.5 .. 5.5 VPower Supply
Open Loop TransducerTechnology
0.2 % (-80 .. 80 A) / 1 % (full range)Linearity Error (Max)
−40 .. 125 °COperating Temperature

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range (IPM)± 112 A
Current Consumption (IC)7.5 .. 10 mA
Output PWM Frequency (fPWM)105 .. 145 Hz
Output Duty Cycle Sensitivity (G)0.4 %/A
Duty Cycle Resolution0.0125 %
Power-up Time to Reach Valid Duty Cycle25 ms

Standards & Approvals

Typical Applications

Output voltage: full ratiometric (in sensitivity and offset)

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The HAB 100-S/SP1 BT4T-14B357-AA is an open loop current transducer from LEM for the electronic measurement of DC, AC or pulsed currents, with galvanic isolation, delivering an instantaneous output voltage of −5 .. 14 V.

Typical applications include Output voltage: full ratiometric (in sensitivity and offset).

Key characteristics from the official datasheet: linearity error 0.2 % (-80 .. 80 A) / 1 % (full range); operating temperature -40 .. 125 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesHAB
Product ReferenceHAB 100-S/SP1
Primary Nominal Current± 100 A
Supply Voltage4.5 .. 5.5 V
MeasurementDC, AC or pulsed currents
MountingBusbar Mount
Application DomainAutomotive applications
Absolute Maximum Ratings
Maximum primary current (IP)Infinite A
Supply voltage−8.5 .. 8.5 V
Supply voltage (over voltage t < 1 min)−14 .. 14 V
Current consumption (t < 1 min) (IC)50 mA
Output voltage (t < 1 min) (Vout)−5 .. 14 V
Output voltage over supply voltage (Vout−VC)2 V
Output current (Iout)−10 .. 10 mA
Output short-circuit duration (tc)10 min
Ambient storage temperature (TS)−40 .. 125 °C
Operating Conditions
Supply voltage (VC)4.5 .. 5.5 V
Supply voltage (accurate range) (VC)4.75 .. 5.25 V
Pull up load resistor (RL)2.2 .. 4.7 kOhm
Capacitive loading (CL)1 nF
Ambient operation temperature (TA)−40 .. 125 °C
Ambient operation temperature (accurate range) (TA)−10 .. 65 °C
Operating Characteristics
Primary current nominal range (IPN)± 100 A
Maximum current measuring range (clamping) (IPM)± 112 A
Current consumption (IC)7.5 .. 10 mA
Output PWM frequency (fPWM)105 .. 145 Hz
Output duty cycle sensitivity (G)0.4 %/A
Output duty cycle @ IP = 050 %
Output duty clamping low (DOUT)4 .. 6 %
Output duty clamping high94 .. 96 %
Duty cycle resolution0.0125 %
Power-up time to reach valid duty cycle25 ms
Setting time after over load25 ms
Output voltage high (pull up = 4.7 kOhm) (VOUTH)VC − 0.2 V
Output voltage low (pull up = 4.7 kOhm) (VOUTL)0.2 V
Output internal resistance (Rout)50 .. 100 Ohm
Output PWM rise time (trise)10 µs
Output PWM fall time (tfall)10 µs
Accuracy
Electric Offset Current @ 25 °C (IOE)± 0.05 A
Magnetic Offset Current @ 25 °C (IOM)± 0.05 A
Global offset current (IO) @ 25 °C± 0.10 A
Global offset current (IO) @ −20 .. 65 °C± 0.15 A
Global offset current (IO) @ −40 .. 125 °C± 0.3 A
Sensitivity error (εG) @ 25 °C± 0.2 %
Sensitivity error (εG) @ −20 .. 65 °C± 0.7 %
Sensitivity error (εG) @ −40 .. 125 °C± 1.5 %
Linearity @ −80 A < IP < 80 A0.2 % of full range
Linearity @ 80 A < |IP| < 100 A1 % of full range

Note: Specifications are taken from the official HAB 100-S/SP1 BT4T-14B357-AA datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the HAB 100-S/SP1 BT4T-14B357-AA are shown below.

HAB 100-S/SP1  BT4T-14B357-AA outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM HAB 100-S/SP1 BT4T-14B357-AA datasheet

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the HAB 100-S/SP1 BT4T-14B357-AA.

Output voltage: full ratiometric (in sensitivity and offset)

Characteristic Curves

Characteristic curve diagrams are not included in the HAB 100-S/SP1 BT4T-14B357-AA datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Accuracy & Dynamic Characteristics
Output duty cycle sensitivity (G)0.4 %/A
Output PWM rise time (trise)10 µs
Output PWM fall time (tfall)10 µs
Sensitivity error (εG) @ 25 °C± 0.2 %
Sensitivity error (εG) @ −20 .. 65 °C± 0.7 %
Sensitivity error (εG) @ −40 .. 125 °C± 1.5 %
Linearity @ −80 A < IP < 80 A0.2 % of full range
Linearity @ 80 A < |IP| < 100 A1 % of full range

Note: For the full set of performance data, refer to the datasheet.