Your Trusted Source for Industrial Electrical Components
Home Products LEM Automotive Series HAB Series HABT 100-V/SP10 28850-BZ010/28850-B2041

HABT 100-V/SP10 28850-BZ010/28850-B2041

Open Loop transducer using the Hall effect

LEM | HAB-Series | Open Loop Transducer | Busbar Mount

± 100 ANominal Primary Current
4.5 .. 5.5 VPower Supply
Open Loop TransducerTechnology
± 0.5 % (up to 80 A) / ± 1 % (up to 100 A)Linearity Error (Max)
−30 .. 90 °COperating Temperature

Additional Technical Details

View Full Specifications
Current Consumption (IC)5 .. 10 mA
Sensitivity20 mV/A
Load Resistance (RL)9 .. 100 kOhm
Insulation Resistance (RINS)10 MOhm
Total error @ IP = 0 A± 0.7 %
Output Clamping Voltage Low5.1 .. 6.9 % UC

Standards & Approvals

Typical Applications

Temperature measurement by embedded NTC. I current across the Hall plates Hall

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The HABT 100-V/SP10 28850-BZ010/28850-B2041 is an open loop current transducer from LEM delivering an instantaneous output voltage of 14 V.

It offers excellent accuracy and very good linearity. Typical applications include Temperature measurement by embedded NTC. I current across the Hall plates Hall.

Key characteristics from the official datasheet: operating temperature −30 .. 90 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesHAB
Product ReferenceHABT 100-V/SP10
Primary Nominal Current± 100 A
Supply Voltage4.5 .. 5.5 V
Measurement—
Mounting—
Application DomainAutomotive applications
Absolute Maximum Ratings
Nominal supply voltage (UC)4.5 .. 5.5 V
Supply continuous over voltage8.5 V
Reverse voltage (Urev)−14 V
Over voltage (UO)14 V
Output voltage (Analog) (U_out)14 V
Output current (I_out)−10 .. 10 mA
Output short-circuit duration (tc)2 min
Insulation resistance (RINS)10 MOhm
Ambient storage temperature (Tst)−40 .. 100 °C
Electrical Data
Supply voltage (UC)4.5 .. 5.5 V
Output current (I_out)−1 .. 1 mA
Sensitivity error (εS)± 0.5 %
Load resistance (RL)9 .. 100 kOhm
Load capacitance (C_L)10 .. 100 nF
Ambient operating temperature (TA)−30 .. 90 °C
Output voltage (diagnostic detection open ground)0.15 V
Output voltage (diagnostic detection open UC)0.15 V
Accuracy & Dynamic Performance
Current consumption (IC)5 .. 10 mA
Linearity error (εL) up to 80 A−0.5 .. 0.5 %
Linearity error (εL) up to 100 A−1 .. 1 %
Total error @ IP = 0 A± 0.7 %
Total error @ IP = 100 A± 3.75 %
Sensitivity (S)20 mV/A
Offset current (I_O)± 300 mA
Electrical offset current (IOE)± 250 mA
Magnetic offset current (IOM)± 200 mA
Primary current, measuring range (IPM)± 100 A
Output voltage @ IP = 02.5 V (UC / 2)
Resolution2.5 mV
Output internal resistance (Rout)1 .. 10 Ohm
Delay time to 90 % of final output value1.1 µs
Start up time (t_start)25 .. 200 µs
Settling time after overload25 µs
NTC resistance (RNTC)2.178 .. 2.222 kOhm
B 25/85 constant3485 .. 3555
Output clamping voltage low5.1 .. 6.9 % UC
Output clamping voltage high92.1 .. 93.9 % UC
Temperature accuracy± 2 °C
Mechanical Characteristics
Plastic casePBT-GF30
Magnetic coreFerromagnetic alloy
PinsGold plated

Note: Specifications are taken from the official HABT 100-V/SP10 28850-BZ010/28850-B2041 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Documents & Downloads

Official technical documentation for the HABT 100-V/SP10 28850-BZ010/28850-B2041.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the HABT 100-V/SP10 28850-BZ010/28850-B2041 are shown below.

HABT 100-V/SP10  28850-BZ010/28850-B2041 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM HABT 100-V/SP10 28850-BZ010/28850-B2041 datasheet

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the HABT 100-V/SP10 28850-BZ010/28850-B2041.

Temperature measurement by embedded NTC. I current across the Hall plates Hall

Characteristic Curves

Characteristic curve diagrams are not included in the HABT 100-V/SP10 28850-BZ010/28850-B2041 datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Accuracy & Dynamic Characteristics
Sensitivity error (εS)± 0.5 %
Linearity error (εL) up to 80 A−0.5 .. 0.5 %
Linearity error (εL) up to 100 A−1 .. 1 %
Total error @ IP = 0 A± 0.7 %
Total error @ IP = 100 A± 3.75 %
Sensitivity (S)20 mV/A
Temperature accuracy± 2 °C
Reference Conditions
Ambient Temperature (TA)25 °C, unless otherwise noted
Output Load Resistance (RL)9 .. 100 kOhm

Note: For the full set of performance data, refer to the datasheet.