Open Loop transducer using the Hall effect sensor
| Primary Current, Measuring Range (IPM) | ± 90 A |
| Current Consumption (IC) | 7.5 .. 10 mA |
| Output PWM Frequency (fPWM) | 105 .. 145 Hz |
| Output Duty Cycle Sensitivity (G) | 0.5 %/A |
| Duty Cycle Resolution | 0.0125 % |
| Power-up Time to Reach Valid Duty Cycle | 25 ms |
Operating temperature range: - 40°C < T° < + 125°C
The HAB 80-S 0S2B6/04-20286 is an open loop current transducer from LEM for the electronic measurement of DC, AC or pulsed currents, with galvanic isolation, delivering an instantaneous output voltage of −5 .. 14 V.
Typical applications include Operating temperature range: - 40°C < T° < + 125°C.
Key characteristics from the official datasheet: operating temperature -40 .. 125 °C.
| General Information | |
|---|---|
| Manufacturer | LEM |
| Product Series | HAB |
| Product Reference | HAB 80-S |
| Primary Nominal Current | ± 80 A |
| Supply Voltage | 4.5 .. 5.5 V |
| Measurement | DC, AC or pulsed currents |
| Mounting | Busbar Mount |
| Application Domain | Automotive applications |
| Absolute Maximum Ratings | |
|---|---|
| Maximum primary current (IP) | Infinite A |
| Supply voltage | −8.5 .. 8.5 V |
| Supply voltage (over voltage t < 1 min) | −14 .. 14 V |
| Current consumption (t < 1 min) (IC) | 50 mA |
| Output voltage (t < 1 min) (Vout) | −5 .. 14 V |
| Output voltage over supply voltage (Vout−VC) | 2 V |
| Output current (Iout) | −10 .. 10 mA |
| Output short-circuit duration (tc) | 10 min |
| Ambient storage temperature (TS) | −40 .. 125 °C |
| Operating Conditions | |
|---|---|
| Supply voltage (VC) | 4.5 .. 5.5 V |
| Supply voltage (accurate range) (VC) | 4.75 .. 5.25 V |
| Pull up load resistor (RL) | 2.2 .. 4.7 kOhm |
| Capacitive loading (CL) | 1 nF |
| Ambient operation temperature (TA) | −40 .. 125 °C |
| Ambient operation temperature (accurate range) (TA) | −10 .. 65 °C |
| Operating Characteristics | |
|---|---|
| Primary current nominal range (IPN) | ± 80 A |
| Maximum current measuring range (clamping) (IPM) | ± 90 A |
| Calibration current (ICAL) | ± 60 A |
| Current consumption (IC) | 7.5 .. 10 mA |
| Output PWM frequency (fPWM) | 105 .. 145 Hz |
| Output duty cycle sensitivity (G) | 0.5 %/A |
| Output duty cycle @ IP = 0 | 50 % |
| Output duty clamping low (DOUT) | 4 .. 6 % |
| Output duty clamping high | 94 .. 96 % |
| Duty cycle resolution | 0.0125 % |
| Power-up time to reach valid duty cycle | 25 ms |
| Setting time after over load | 25 ms |
| Output voltage high (pull up = 4.7 kOhm) (VOUTH) | VC − 0.2 V |
| Output voltage low (pull up = 4.7 kOhm) (VOUTL) | 0.2 V |
| Output internal resistance (Rout) | 50 .. 100 Ohm |
| Output PWM rise time (trise) | 10 µs |
| Output PWM fall time (tfall) | 10 µs |
| Accuracy & Dynamic Performance | |
|---|---|
| Electric offset current @ accurate temperature range (IOE) | −0.2 .. 0.2 A |
| Electric offset current @ full temperature range (IOE) | −0.3 .. 0.3 A |
| Magnetic offset current (IOM) | ± 0.05 A |
| Output resolution | 0.04 A |
| Sensitivity error @ accurate temperature range (εG) | −2 .. 2 % |
| Sensitivity error @ full temperature range (εG) | −3 .. 3 % |
| Linearity error @ 25 °C (εL) | −1 .. 1 % |
Note: Specifications are taken from the official HAB 80-S 0S2B6/04-20286 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.
Official technical documentation for the HAB 80-S 0S2B6/04-20286.
Outline dimensions, pin layout and connection diagrams of the HAB 80-S 0S2B6/04-20286 are shown below.
Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.
Typical applications of the HAB 80-S 0S2B6/04-20286.
Characteristic curve diagrams are not included in the HAB 80-S 0S2B6/04-20286 datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.
| Accuracy & Dynamic Characteristics | |
|---|---|
| Output duty cycle sensitivity (G) | 0.5 %/A |
| Output PWM rise time (trise) | 10 µs |
| Output PWM fall time (tfall) | 10 µs |
| Sensitivity error @ accurate temperature range (εG) | −2 .. 2 % |
| Sensitivity error @ full temperature range (εG) | −3 .. 3 % |
| Linearity error @ 25 °C (εL) | −1 .. 1 % |
Note: For the full set of performance data, refer to the datasheet.